Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss

Hearing screening is an essential test to detect hearing ability of someone. A good hearing ability is absolutely necessary for a normal speech development. In cases with pronounced hearing loss even no speech ability will develop at all causing serious communication problems and impaired intellectu...

Full description

Saved in:
Bibliographic Details
Main Author: Muhamed, Mohd. Rushaidin
Format: Thesis
Language:English
Published: 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/16934/1/MohdRushaidinMuhamedMFKE2011.pdf
http://eprints.utm.my/id/eprint/16934/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.16934
record_format eprints
spelling my.utm.169342018-05-27T03:24:05Z http://eprints.utm.my/id/eprint/16934/ Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss Muhamed, Mohd. Rushaidin TK Electrical engineering. Electronics Nuclear engineering Hearing screening is an essential test to detect hearing ability of someone. A good hearing ability is absolutely necessary for a normal speech development. In cases with pronounced hearing loss even no speech ability will develop at all causing serious communication problems and impaired intellectual and emotional development. Auditory brainstem response is a well known method that has been used on detection of hearing problem. An alternative method was also introduced in this thesis in detecting the hearing loss problem. Evoked potentials are used because they can indicate problem along nerve pathways that are too subtle to show up during neurologic examination or to be noticed by the person. This description may not be visible on magnetic resonance imaging test. This study proposes methods of identifying hearing loss based on continuous wavelet transforms (CWT) and instantaneous energy (IE). Study showed that the IE performed better than the CWT with the sensitivity of 0.88 and specificity of 0.81 compared to the CWT with the sensitivity of 0.63 and specificity of 0.83. Significance of the results is 0.42.This experiments result can be used as a basis to improve methods of detection hearing loss. 2011-02 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/16934/1/MohdRushaidinMuhamedMFKE2011.pdf Muhamed, Mohd. Rushaidin (2011) Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Muhamed, Mohd. Rushaidin
Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss
description Hearing screening is an essential test to detect hearing ability of someone. A good hearing ability is absolutely necessary for a normal speech development. In cases with pronounced hearing loss even no speech ability will develop at all causing serious communication problems and impaired intellectual and emotional development. Auditory brainstem response is a well known method that has been used on detection of hearing problem. An alternative method was also introduced in this thesis in detecting the hearing loss problem. Evoked potentials are used because they can indicate problem along nerve pathways that are too subtle to show up during neurologic examination or to be noticed by the person. This description may not be visible on magnetic resonance imaging test. This study proposes methods of identifying hearing loss based on continuous wavelet transforms (CWT) and instantaneous energy (IE). Study showed that the IE performed better than the CWT with the sensitivity of 0.88 and specificity of 0.81 compared to the CWT with the sensitivity of 0.63 and specificity of 0.83. Significance of the results is 0.42.This experiments result can be used as a basis to improve methods of detection hearing loss.
format Thesis
author Muhamed, Mohd. Rushaidin
author_facet Muhamed, Mohd. Rushaidin
author_sort Muhamed, Mohd. Rushaidin
title Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss
title_short Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss
title_full Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss
title_fullStr Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss
title_full_unstemmed Detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss
title_sort detection of wave v using continuous wavelet transform and instanstaneous energy for hearing loss
publishDate 2011
url http://eprints.utm.my/id/eprint/16934/1/MohdRushaidinMuhamedMFKE2011.pdf
http://eprints.utm.my/id/eprint/16934/
_version_ 1643646680988385280