The Design And Simulation Of Flow Mode Electrorheological Damper
Electrorheological (ER) Damper Is A Damper That Utilizes Electrorheological Fluid As The Working Fluid. By Changing The Strength Of Applied Electric Field To The Fluid, The Flow Resistance Of The Fluid Changes And Hence The Damping Characteristic Could Be Adjusted. This Paper Provides Theoretical F...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2006
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/1714/1/JTJun44A%5B08%5D.pdf http://eprints.utm.my/id/eprint/1714/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.1714 |
---|---|
record_format |
eprints |
spelling |
my.utm.17142017-11-01T04:17:30Z http://eprints.utm.my/id/eprint/1714/ The Design And Simulation Of Flow Mode Electrorheological Damper Mukhlis, Reiza Zakia Nik Mohamed2, Nik Abdullah Mohd. Nor, Mohd. Jailani Q Science (General) Electrorheological (ER) Damper Is A Damper That Utilizes Electrorheological Fluid As The Working Fluid. By Changing The Strength Of Applied Electric Field To The Fluid, The Flow Resistance Of The Fluid Changes And Hence The Damping Characteristic Could Be Adjusted. This Paper Provides Theoretical Formulation To Calculate The Damping Constant Of Semi-Active Flow Mode ER Damper. The Formula Is Developed By Analyzing Fluid Velocity Profile That Flows In Electrode Gap. From The Simulation, It Shows That Electric Field Strength Gives Severe Effect To The Damping Level Of The Damper. Without Applying Electric Field, A Reduction On The Gap Of Electrode From 3 To 1 Mm Will Increase The Damping Constant Value By A Factor Of Only 27, While With A 3 Kvmm–1 Electric Field Being Applied, The Increase Is By A Factor Of 595. Penerbit UTM Press 2006-06 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/1714/1/JTJun44A%5B08%5D.pdf Mukhlis, Reiza Zakia and Nik Mohamed2, Nik Abdullah and Mohd. Nor, Mohd. Jailani (2006) The Design And Simulation Of Flow Mode Electrorheological Damper. Jurnal Teknologi (A) , 44 (A). pp. 115-125. ISSN 0127-9696 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
Q Science (General) |
spellingShingle |
Q Science (General) Mukhlis, Reiza Zakia Nik Mohamed2, Nik Abdullah Mohd. Nor, Mohd. Jailani The Design And Simulation Of Flow Mode Electrorheological Damper |
description |
Electrorheological (ER) Damper Is A Damper That Utilizes Electrorheological Fluid As The Working Fluid. By Changing The Strength Of Applied Electric Field To The Fluid, The Flow Resistance Of The Fluid Changes And Hence The Damping Characteristic Could Be Adjusted. This Paper Provides
Theoretical Formulation To Calculate The Damping Constant Of Semi-Active Flow Mode ER Damper. The Formula Is Developed By Analyzing Fluid Velocity Profile That Flows In Electrode Gap. From The Simulation, It Shows That Electric Field Strength Gives Severe Effect To The Damping Level Of The
Damper. Without Applying Electric Field, A Reduction On The Gap Of Electrode From 3 To 1 Mm Will Increase The Damping Constant Value By A Factor Of Only 27, While With A 3 Kvmm–1 Electric Field Being Applied, The Increase Is By A Factor Of 595.
|
format |
Article |
author |
Mukhlis, Reiza Zakia Nik Mohamed2, Nik Abdullah Mohd. Nor, Mohd. Jailani |
author_facet |
Mukhlis, Reiza Zakia Nik Mohamed2, Nik Abdullah Mohd. Nor, Mohd. Jailani |
author_sort |
Mukhlis, Reiza Zakia |
title |
The Design And Simulation Of Flow Mode Electrorheological Damper
|
title_short |
The Design And Simulation Of Flow Mode Electrorheological Damper
|
title_full |
The Design And Simulation Of Flow Mode Electrorheological Damper
|
title_fullStr |
The Design And Simulation Of Flow Mode Electrorheological Damper
|
title_full_unstemmed |
The Design And Simulation Of Flow Mode Electrorheological Damper
|
title_sort |
design and simulation of flow mode electrorheological damper |
publisher |
Penerbit UTM Press |
publishDate |
2006 |
url |
http://eprints.utm.my/id/eprint/1714/1/JTJun44A%5B08%5D.pdf http://eprints.utm.my/id/eprint/1714/ |
_version_ |
1643643398033244160 |