A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters

This paper proposes an online algorithm to calculate the switching angles of the selective harmonic elimination pulse-width modulation (SHE-PWM) scheme for voltage source inverters (VSIs). It is based on the quadratic curve fitting of the trajectories of the exact SHEPWM angles. The result is a gene...

Full description

Saved in:
Bibliographic Details
Main Author: Salam, Zainal
Format: Article
Published: Institution of Engineers Australia 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/22827/
https://www.scopus.com/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.22827
record_format eprints
spelling my.utm.228272018-03-13T18:05:37Z http://eprints.utm.my/id/eprint/22827/ A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters Salam, Zainal TK Electrical engineering. Electronics Nuclear engineering This paper proposes an online algorithm to calculate the switching angles of the selective harmonic elimination pulse-width modulation (SHE-PWM) scheme for voltage source inverters (VSIs). It is based on the quadratic curve fitting of the trajectories of the exact SHEPWM angles. The result is a generalised quadratic equation that requires only the addition and multiplication processes, allowing its implementation using a low-cost microprocessor. Changes to the number of harmonics to be eliminated and the fundamental amplitude of the pole switching waveform (NP1) can be calculated independently. This feature is particularly suitable for motor drive applications. An extensive analysis to determine the accuracy of the algorithm is carried out. It is found that the maximum difference between the exact angle and the one calculated using this scheme (defined as angle error) is less than 1° for 0 < NP1 < 0.8. For higher values of NP1 (including over-modulation), the angle error is about 8°. However, by incorporating an error correction scheme, the angle error is reduced to between 3-6 times. To verify the workability of the technique, an experimental single-phase VSI is constructed. The SHE-PWM algorithm is implemented using a fixed-point, 16-bit microprocessor. For comparison, a MATLAB simulation of the same inverter system is carried out. The result obtained from the test rig is in very close agreement with the theoretical prediction and simulation. Institution of Engineers Australia 2010 Article PeerReviewed Salam, Zainal (2010) A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters. Australian Journal of Electrical & Electronics Engineering, 7 (2). 133 - 144. ISSN 1448837X https://www.scopus.com/
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Salam, Zainal
A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters
description This paper proposes an online algorithm to calculate the switching angles of the selective harmonic elimination pulse-width modulation (SHE-PWM) scheme for voltage source inverters (VSIs). It is based on the quadratic curve fitting of the trajectories of the exact SHEPWM angles. The result is a generalised quadratic equation that requires only the addition and multiplication processes, allowing its implementation using a low-cost microprocessor. Changes to the number of harmonics to be eliminated and the fundamental amplitude of the pole switching waveform (NP1) can be calculated independently. This feature is particularly suitable for motor drive applications. An extensive analysis to determine the accuracy of the algorithm is carried out. It is found that the maximum difference between the exact angle and the one calculated using this scheme (defined as angle error) is less than 1° for 0 < NP1 < 0.8. For higher values of NP1 (including over-modulation), the angle error is about 8°. However, by incorporating an error correction scheme, the angle error is reduced to between 3-6 times. To verify the workability of the technique, an experimental single-phase VSI is constructed. The SHE-PWM algorithm is implemented using a fixed-point, 16-bit microprocessor. For comparison, a MATLAB simulation of the same inverter system is carried out. The result obtained from the test rig is in very close agreement with the theoretical prediction and simulation.
format Article
author Salam, Zainal
author_facet Salam, Zainal
author_sort Salam, Zainal
title A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters
title_short A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters
title_full A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters
title_fullStr A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters
title_full_unstemmed A simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters
title_sort simple online selective harmonic elimination pulse width modulation scheme for voltage source inverters
publisher Institution of Engineers Australia
publishDate 2010
url http://eprints.utm.my/id/eprint/22827/
https://www.scopus.com/
_version_ 1643647408687546368