Physical image quality evaluation of medical radiographs

The noise equivalent quanta (NEQ) has been recommended as a measure of physical quality of medical images. Digitised data of medical radiographs in a previous work have been analysed in terms of resolution via the modulation transfer function (MTF) and noise via the noise power spectrum (NPS), but n...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Hassan, Wan Muhamad Saridan, Munajat, Yusof, Sahibuddin, Shamsul
Format: Article
Language:English
Published: Malaysian Institute of Physics 2002
Subjects:
Online Access:http://eprints.utm.my/id/eprint/2502/1/Jurnal_Fizik_Malaysia_23_2002_201-206.pdf
http://eprints.utm.my/id/eprint/2502/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.2502
record_format eprints
spelling my.utm.25022010-06-01T03:03:20Z http://eprints.utm.my/id/eprint/2502/ Physical image quality evaluation of medical radiographs Wan Hassan, Wan Muhamad Saridan Munajat, Yusof Sahibuddin, Shamsul QC Physics The noise equivalent quanta (NEQ) has been recommended as a measure of physical quality of medical images. Digitised data of medical radiographs in a previous work have been analysed in terms of resolution via the modulation transfer function (MTF) and noise via the noise power spectrum (NPS), but not in terms of NEQ. As the NEQ is currently regarded as a basic device performance measure of the imaging system, it is very useful to be able to determine it. The average gamma of the radiograph was computed, both the MTF and the NPS data were interpolated and these values were used to compute the NEQ. The computation shows that for spatial frequency range 0–0.7 cycles/mm the NEQ of Lanex Regular/T Mat G screen-film combination is slightly lower than that of Lanex Regular/T Mat L, for 0.7–1.5 cycles/mm the NEQ of both are almost the same, and for frequencies greater than 1.5 cycles/mm the NEQ of the former is greater than that of the latter. Malaysian Institute of Physics 2002 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/2502/1/Jurnal_Fizik_Malaysia_23_2002_201-206.pdf Wan Hassan, Wan Muhamad Saridan and Munajat, Yusof and Sahibuddin, Shamsul (2002) Physical image quality evaluation of medical radiographs. Jurnal Fizik Malaysia, 23 . pp. 201-206. ISSN 0128-0333
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic QC Physics
spellingShingle QC Physics
Wan Hassan, Wan Muhamad Saridan
Munajat, Yusof
Sahibuddin, Shamsul
Physical image quality evaluation of medical radiographs
description The noise equivalent quanta (NEQ) has been recommended as a measure of physical quality of medical images. Digitised data of medical radiographs in a previous work have been analysed in terms of resolution via the modulation transfer function (MTF) and noise via the noise power spectrum (NPS), but not in terms of NEQ. As the NEQ is currently regarded as a basic device performance measure of the imaging system, it is very useful to be able to determine it. The average gamma of the radiograph was computed, both the MTF and the NPS data were interpolated and these values were used to compute the NEQ. The computation shows that for spatial frequency range 0–0.7 cycles/mm the NEQ of Lanex Regular/T Mat G screen-film combination is slightly lower than that of Lanex Regular/T Mat L, for 0.7–1.5 cycles/mm the NEQ of both are almost the same, and for frequencies greater than 1.5 cycles/mm the NEQ of the former is greater than that of the latter.
format Article
author Wan Hassan, Wan Muhamad Saridan
Munajat, Yusof
Sahibuddin, Shamsul
author_facet Wan Hassan, Wan Muhamad Saridan
Munajat, Yusof
Sahibuddin, Shamsul
author_sort Wan Hassan, Wan Muhamad Saridan
title Physical image quality evaluation of medical radiographs
title_short Physical image quality evaluation of medical radiographs
title_full Physical image quality evaluation of medical radiographs
title_fullStr Physical image quality evaluation of medical radiographs
title_full_unstemmed Physical image quality evaluation of medical radiographs
title_sort physical image quality evaluation of medical radiographs
publisher Malaysian Institute of Physics
publishDate 2002
url http://eprints.utm.my/id/eprint/2502/1/Jurnal_Fizik_Malaysia_23_2002_201-206.pdf
http://eprints.utm.my/id/eprint/2502/
_version_ 1643643594589863936