Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function

The sub-system interaction and instability phenomena is a common problem in the Distributed Power System (DPS). The interaction arises because an individual converter known as constant power load (CPL), has internal control function such as to regulate the converter output voltage, which results in...

Full description

Saved in:
Bibliographic Details
Main Authors: Jusoh, Awang, Forsyth, A. J., Salam, Zainal
Format: Article
Language:English
Published: Penerbit UTM Press 2006
Subjects:
Online Access:http://eprints.utm.my/id/eprint/2580/1/JTjun44D%5B5%5DCRC.pdf
http://eprints.utm.my/id/eprint/2580/
http://www.penerbit.utm.my/onlinejournal/44/D/JTjun44D05.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.2580
record_format eprints
spelling my.utm.25802017-11-01T04:17:29Z http://eprints.utm.my/id/eprint/2580/ Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function Jusoh, Awang Forsyth, A. J. Salam, Zainal TK Electrical engineering. Electronics Nuclear engineering The sub-system interaction and instability phenomena is a common problem in the Distributed Power System (DPS). The interaction arises because an individual converter known as constant power load (CPL), has internal control function such as to regulate the converter output voltage, which results in the converter tends to draw a constant power. The input impedance of CPL has a negative incremental input impedance, which tends to create instability as it is connected to a system. This paper presents the analysis and control of the DC-DC converter used to perform an active damping function in a DPS, comprising L-C filters and CPLs. The DC-DC converter was modelled using averaged technique. The small-signal analysis is performed and the controller was designed on such a way to regulate the converter input current. The design of the control loop parameters based on the frequency domain is demonstrated. The effectiveness of the active damping method was verified by MATLAB Simulink simulation. Penerbit UTM Press 2006-06 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/2580/1/JTjun44D%5B5%5DCRC.pdf Jusoh, Awang and Forsyth, A. J. and Salam, Zainal (2006) Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function. Jurnal Teknologi D (44D). pp. 65-84. ISSN 0127-9696 http://www.penerbit.utm.my/onlinejournal/44/D/JTjun44D05.pdf
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Jusoh, Awang
Forsyth, A. J.
Salam, Zainal
Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function
description The sub-system interaction and instability phenomena is a common problem in the Distributed Power System (DPS). The interaction arises because an individual converter known as constant power load (CPL), has internal control function such as to regulate the converter output voltage, which results in the converter tends to draw a constant power. The input impedance of CPL has a negative incremental input impedance, which tends to create instability as it is connected to a system. This paper presents the analysis and control of the DC-DC converter used to perform an active damping function in a DPS, comprising L-C filters and CPLs. The DC-DC converter was modelled using averaged technique. The small-signal analysis is performed and the controller was designed on such a way to regulate the converter input current. The design of the control loop parameters based on the frequency domain is demonstrated. The effectiveness of the active damping method was verified by MATLAB Simulink simulation.
format Article
author Jusoh, Awang
Forsyth, A. J.
Salam, Zainal
author_facet Jusoh, Awang
Forsyth, A. J.
Salam, Zainal
author_sort Jusoh, Awang
title Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function
title_short Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function
title_full Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function
title_fullStr Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function
title_full_unstemmed Analysis and control of the unloaded BI-directional DC/DC converter to perform an active damping function
title_sort analysis and control of the unloaded bi-directional dc/dc converter to perform an active damping function
publisher Penerbit UTM Press
publishDate 2006
url http://eprints.utm.my/id/eprint/2580/1/JTjun44D%5B5%5DCRC.pdf
http://eprints.utm.my/id/eprint/2580/
http://www.penerbit.utm.my/onlinejournal/44/D/JTjun44D05.pdf
_version_ 1643643607611080704