Optical tomography system using microprocessor and ethernet controller-based data acquisition system
Purpose – Owing to the high cost of data acquisition (DAQ) card in the market, the purpose of this paper is to develop a high speed, low-cost microprocessor and ethernet controller-based DAQ in optical tomography system. Design/methodology/approach – Microprocessor is the main core to control the se...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Emerald Group Publishing Limited
2010
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/26539/ https://www.emeraldinsight.com/doi/pdfplus/10.1108/02602281011022715 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.26539 |
---|---|
record_format |
eprints |
spelling |
my.utm.265392018-09-22T08:22:43Z http://eprints.utm.my/id/eprint/26539/ Optical tomography system using microprocessor and ethernet controller-based data acquisition system Abd. Rahim, Ruzairi Goh, Chiew Loon Rahiman, Mohd. Hafiz Fazalul Chan, Kok San Pang, Jon Fea Leong, Lai Chan TK Electrical engineering. Electronics Nuclear engineering Purpose – Owing to the high cost of data acquisition (DAQ) card in the market, the purpose of this paper is to develop a high speed, low-cost microprocessor and ethernet controller-based DAQ in optical tomography system. Design/methodology/approach – Microprocessor is the main core to control the sensor circuitry while ethernet controller has the responsibility of transmitting data to PC and thus insuring the reliability of data. Findings – The data transfer rate will be up to megabytes per seconds. In this optical tomography system, projection geometry combining two orthogonal and two rectilinear in one layer is modeled. Originality/value – This paper presents a new application in optical tomography. Emerald Group Publishing Limited 2010 Article PeerReviewed Abd. Rahim, Ruzairi and Goh, Chiew Loon and Rahiman, Mohd. Hafiz Fazalul and Chan, Kok San and Pang, Jon Fea and Leong, Lai Chan (2010) Optical tomography system using microprocessor and ethernet controller-based data acquisition system. Sensor Review, 30 (2). 124 -129. ISSN 0260-2288 https://www.emeraldinsight.com/doi/pdfplus/10.1108/02602281011022715 DOI:10.1108/02602281011022715 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Abd. Rahim, Ruzairi Goh, Chiew Loon Rahiman, Mohd. Hafiz Fazalul Chan, Kok San Pang, Jon Fea Leong, Lai Chan Optical tomography system using microprocessor and ethernet controller-based data acquisition system |
description |
Purpose – Owing to the high cost of data acquisition (DAQ) card in the market, the purpose of this paper is to develop a high speed, low-cost microprocessor and ethernet controller-based DAQ in optical tomography system. Design/methodology/approach – Microprocessor is the main core to control the sensor circuitry while ethernet controller has the responsibility of transmitting data to PC and thus insuring the reliability of data. Findings – The data transfer rate will be up to megabytes per seconds. In this optical tomography system, projection geometry combining two orthogonal and two rectilinear in one layer is modeled. Originality/value – This paper presents a new application in optical tomography. |
format |
Article |
author |
Abd. Rahim, Ruzairi Goh, Chiew Loon Rahiman, Mohd. Hafiz Fazalul Chan, Kok San Pang, Jon Fea Leong, Lai Chan |
author_facet |
Abd. Rahim, Ruzairi Goh, Chiew Loon Rahiman, Mohd. Hafiz Fazalul Chan, Kok San Pang, Jon Fea Leong, Lai Chan |
author_sort |
Abd. Rahim, Ruzairi |
title |
Optical tomography system using microprocessor and ethernet controller-based data acquisition system |
title_short |
Optical tomography system using microprocessor and ethernet controller-based data acquisition system |
title_full |
Optical tomography system using microprocessor and ethernet controller-based data acquisition system |
title_fullStr |
Optical tomography system using microprocessor and ethernet controller-based data acquisition system |
title_full_unstemmed |
Optical tomography system using microprocessor and ethernet controller-based data acquisition system |
title_sort |
optical tomography system using microprocessor and ethernet controller-based data acquisition system |
publisher |
Emerald Group Publishing Limited |
publishDate |
2010 |
url |
http://eprints.utm.my/id/eprint/26539/ https://www.emeraldinsight.com/doi/pdfplus/10.1108/02602281011022715 |
_version_ |
1643647788588728320 |