Droplet size measurement for liquid spray using digital image analysis technique

The developed Digital Image Analysis (DIA) system has been examined in terms of its capability to characterise the high speed, fine droplet at downstream of a spray atomiser. The architecture and working principle of the DIA system were explained. This system has employed a high intensity pulsed las...

Full description

Saved in:
Bibliographic Details
Main Authors: Lad, N., Aroussi, A., Muhamad Said, Mohd. Farid
Format: Article
Language:English
Published: Asian Network for Scientific Information 2011
Subjects:
Online Access:http://eprints.utm.my/id/eprint/28976/1/MFaridMuhamadSaid2011_DropletSizeMeasurementforLiquidSpray.pdf
http://eprints.utm.my/id/eprint/28976/
http://dx.doi.org/10.3923/jas.2011.1966.1972
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.28976
record_format eprints
spelling my.utm.289762020-10-22T04:04:04Z http://eprints.utm.my/id/eprint/28976/ Droplet size measurement for liquid spray using digital image analysis technique Lad, N. Aroussi, A. Muhamad Said, Mohd. Farid TJ Mechanical engineering and machinery The developed Digital Image Analysis (DIA) system has been examined in terms of its capability to characterise the high speed, fine droplet at downstream of a spray atomiser. The architecture and working principle of the DIA system were explained. This system has employed a high intensity pulsed laser as a light source and a digital camera to capture the droplet images. The DIA technique has been implemented in extracting the valuable information of spray droplet from the images. Image processing algorithms were applied in the development of the software and they were described in this paper. In order to evaluate the repeatability of the DIA system, the measurement of droplet size was repeated several times. The deviation result has confirmed that the DIA system has a good repeatability on sizing the drops. The available methods to characterize the droplet spray were briefly explained. The DIA system was used to investigate the effect of a circular cylinder on the drop size of an atomizer at downstream of the spray flow. The cylinder was introduced at 250 mm downstream of the nozzle exit. The measured mean drop size for 'with cylinder' and'no cylinder' were at 9.2 and 8.1 urn, respectively. It was observed that due to the coalescence of the drops after it passed through the cylinder, the mean drop size were found to be slightly larger when the circular cylinder is introduced. Asian Network for Scientific Information 2011 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/28976/1/MFaridMuhamadSaid2011_DropletSizeMeasurementforLiquidSpray.pdf Lad, N. and Aroussi, A. and Muhamad Said, Mohd. Farid (2011) Droplet size measurement for liquid spray using digital image analysis technique. Journal of Applied Sciences, 11 (11). pp. 1966-1972. ISSN 1812-5654 http://dx.doi.org/10.3923/jas.2011.1966.1972 DOI:10.3923/jas.2011.1966.1972
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Lad, N.
Aroussi, A.
Muhamad Said, Mohd. Farid
Droplet size measurement for liquid spray using digital image analysis technique
description The developed Digital Image Analysis (DIA) system has been examined in terms of its capability to characterise the high speed, fine droplet at downstream of a spray atomiser. The architecture and working principle of the DIA system were explained. This system has employed a high intensity pulsed laser as a light source and a digital camera to capture the droplet images. The DIA technique has been implemented in extracting the valuable information of spray droplet from the images. Image processing algorithms were applied in the development of the software and they were described in this paper. In order to evaluate the repeatability of the DIA system, the measurement of droplet size was repeated several times. The deviation result has confirmed that the DIA system has a good repeatability on sizing the drops. The available methods to characterize the droplet spray were briefly explained. The DIA system was used to investigate the effect of a circular cylinder on the drop size of an atomizer at downstream of the spray flow. The cylinder was introduced at 250 mm downstream of the nozzle exit. The measured mean drop size for 'with cylinder' and'no cylinder' were at 9.2 and 8.1 urn, respectively. It was observed that due to the coalescence of the drops after it passed through the cylinder, the mean drop size were found to be slightly larger when the circular cylinder is introduced.
format Article
author Lad, N.
Aroussi, A.
Muhamad Said, Mohd. Farid
author_facet Lad, N.
Aroussi, A.
Muhamad Said, Mohd. Farid
author_sort Lad, N.
title Droplet size measurement for liquid spray using digital image analysis technique
title_short Droplet size measurement for liquid spray using digital image analysis technique
title_full Droplet size measurement for liquid spray using digital image analysis technique
title_fullStr Droplet size measurement for liquid spray using digital image analysis technique
title_full_unstemmed Droplet size measurement for liquid spray using digital image analysis technique
title_sort droplet size measurement for liquid spray using digital image analysis technique
publisher Asian Network for Scientific Information
publishDate 2011
url http://eprints.utm.my/id/eprint/28976/1/MFaridMuhamadSaid2011_DropletSizeMeasurementforLiquidSpray.pdf
http://eprints.utm.my/id/eprint/28976/
http://dx.doi.org/10.3923/jas.2011.1966.1972
_version_ 1681489435996192768