Fault location on overhead transmission line using phasor measurement unit

Fault location on overhead transmission line using phasor measurement unit” is a study for obtaining the accurate location of fault occurred in power transmission. The fault location studies have attracted interest among researchers since 2000 due to the increase in awareness of the importance of pr...

Full description

Saved in:
Bibliographic Details
Main Author: Idris, Muhammad Faizul
Format: Thesis
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/32087/5/MuhammadFaizulIdrisMFKE2012.pdf
http://eprints.utm.my/id/eprint/32087/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:69789?site_name=Restricted Repository
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.32087
record_format eprints
spelling my.utm.320872017-09-25T04:19:29Z http://eprints.utm.my/id/eprint/32087/ Fault location on overhead transmission line using phasor measurement unit Idris, Muhammad Faizul TK Electrical engineering. Electronics Nuclear engineering Fault location on overhead transmission line using phasor measurement unit” is a study for obtaining the accurate location of fault occurred in power transmission. The fault location studies have attracted interest among researchers since 2000 due to the increase in awareness of the importance of providing a reliable and effective utilities services. This study chooses impedance-based, travelling wave and phasor as fault location methods since they are well developed and recognized for providing accurate and reliable results. The power system network is modeled using ATP-EMTP and Power World software, and the outputs are manipulated into calculation based on algorithm. According to the results, the most accurate method is travelling wave, followed by phasor and impedance-based method. This study also discusses factors that affect the results to each of the methods. The advantages of these methods to the power industry include providing improvement in the aspects of reducing down-time, minimising damage, saving utilities cost, etc. 2012-06 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/32087/5/MuhammadFaizulIdrisMFKE2012.pdf Idris, Muhammad Faizul (2012) Fault location on overhead transmission line using phasor measurement unit. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:69789?site_name=Restricted Repository
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Idris, Muhammad Faizul
Fault location on overhead transmission line using phasor measurement unit
description Fault location on overhead transmission line using phasor measurement unit” is a study for obtaining the accurate location of fault occurred in power transmission. The fault location studies have attracted interest among researchers since 2000 due to the increase in awareness of the importance of providing a reliable and effective utilities services. This study chooses impedance-based, travelling wave and phasor as fault location methods since they are well developed and recognized for providing accurate and reliable results. The power system network is modeled using ATP-EMTP and Power World software, and the outputs are manipulated into calculation based on algorithm. According to the results, the most accurate method is travelling wave, followed by phasor and impedance-based method. This study also discusses factors that affect the results to each of the methods. The advantages of these methods to the power industry include providing improvement in the aspects of reducing down-time, minimising damage, saving utilities cost, etc.
format Thesis
author Idris, Muhammad Faizul
author_facet Idris, Muhammad Faizul
author_sort Idris, Muhammad Faizul
title Fault location on overhead transmission line using phasor measurement unit
title_short Fault location on overhead transmission line using phasor measurement unit
title_full Fault location on overhead transmission line using phasor measurement unit
title_fullStr Fault location on overhead transmission line using phasor measurement unit
title_full_unstemmed Fault location on overhead transmission line using phasor measurement unit
title_sort fault location on overhead transmission line using phasor measurement unit
publishDate 2012
url http://eprints.utm.my/id/eprint/32087/5/MuhammadFaizulIdrisMFKE2012.pdf
http://eprints.utm.my/id/eprint/32087/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:69789?site_name=Restricted Repository
_version_ 1643648937085632512