Building façade design for daylighting quality in typical government office building

Daylighting is one of the potential passive strategies to improve energy performance and users' visual comfort in existing offices without expensive installation and operational cost. For the first time, empirical study of daylighting performance was conducted for an existing typical government...

Full description

Saved in:
Bibliographic Details
Main Authors: Lim , Yaik Wah, Kandar, Mohd. Zin, Ahmad, Mohd. Hamdan, Ossen, Dilshan Remaz
Format: Article
Published: Elsevier Ltd. 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/37044/
http://dx.doi.org/10.1016/j.buildenv.2012.04.015
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.37044
record_format eprints
spelling my.utm.370442017-02-15T00:36:15Z http://eprints.utm.my/id/eprint/37044/ Building façade design for daylighting quality in typical government office building Lim , Yaik Wah Kandar, Mohd. Zin Ahmad, Mohd. Hamdan Ossen, Dilshan Remaz NA Architecture Daylighting is one of the potential passive strategies to improve energy performance and users' visual comfort in existing offices without expensive installation and operational cost. For the first time, empirical study of daylighting performance was conducted for an existing typical government office building designed by Public Work Department (PWD) in Malaysia. Daylight field measurement of external illuminance and internal work plane illuminance was carried out. The findings demonstrated that internal daylight level in the building was insufficient despite the abundance of external daylight availability in the tropics which can achieve as high as 130 klx. Validation of simulation using Radiance-based software against the measurement under actual tropical sky indicated significant Pearson correlation of 0.709. Then, modification of window glazing and shading devices was experimented with simulation. The findings evidenced that light shelf increased daylight distribution uniformity, but failed to reduce glare on vertical plane when direct sunlight patches occurred. Integration of light shelf with partial blinds tilted at 45° showed improved performances of mean Guth Visual Comfort Probability (VCP) and CIE Glare Index. This paper concludes that simple modification of window glazing and shading device is able to provide significant improvement in tropical daylighting quantity and quality for visual comfort. Elsevier Ltd. 2012 Article PeerReviewed Lim , Yaik Wah and Kandar, Mohd. Zin and Ahmad, Mohd. Hamdan and Ossen, Dilshan Remaz (2012) Building façade design for daylighting quality in typical government office building. Building and Environment, 57 (2012). pp. 194-204. ISSN 0360-1323 http://dx.doi.org/10.1016/j.buildenv.2012.04.015 DOI:10.1016/j.buildenv.2012.04.015
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic NA Architecture
spellingShingle NA Architecture
Lim , Yaik Wah
Kandar, Mohd. Zin
Ahmad, Mohd. Hamdan
Ossen, Dilshan Remaz
Building façade design for daylighting quality in typical government office building
description Daylighting is one of the potential passive strategies to improve energy performance and users' visual comfort in existing offices without expensive installation and operational cost. For the first time, empirical study of daylighting performance was conducted for an existing typical government office building designed by Public Work Department (PWD) in Malaysia. Daylight field measurement of external illuminance and internal work plane illuminance was carried out. The findings demonstrated that internal daylight level in the building was insufficient despite the abundance of external daylight availability in the tropics which can achieve as high as 130 klx. Validation of simulation using Radiance-based software against the measurement under actual tropical sky indicated significant Pearson correlation of 0.709. Then, modification of window glazing and shading devices was experimented with simulation. The findings evidenced that light shelf increased daylight distribution uniformity, but failed to reduce glare on vertical plane when direct sunlight patches occurred. Integration of light shelf with partial blinds tilted at 45° showed improved performances of mean Guth Visual Comfort Probability (VCP) and CIE Glare Index. This paper concludes that simple modification of window glazing and shading device is able to provide significant improvement in tropical daylighting quantity and quality for visual comfort.
format Article
author Lim , Yaik Wah
Kandar, Mohd. Zin
Ahmad, Mohd. Hamdan
Ossen, Dilshan Remaz
author_facet Lim , Yaik Wah
Kandar, Mohd. Zin
Ahmad, Mohd. Hamdan
Ossen, Dilshan Remaz
author_sort Lim , Yaik Wah
title Building façade design for daylighting quality in typical government office building
title_short Building façade design for daylighting quality in typical government office building
title_full Building façade design for daylighting quality in typical government office building
title_fullStr Building façade design for daylighting quality in typical government office building
title_full_unstemmed Building façade design for daylighting quality in typical government office building
title_sort building façade design for daylighting quality in typical government office building
publisher Elsevier Ltd.
publishDate 2012
url http://eprints.utm.my/id/eprint/37044/
http://dx.doi.org/10.1016/j.buildenv.2012.04.015
_version_ 1643650069584412672