Effects of spiral on the bond stress-slip relationship in the splice sleeve connector

Connections are defined as the system to transmit the forces among the precast element and provide the strength and ductility. Therefore, the connection system of the precast concrete structure must be designed in such way that its structural performance is equivalent to that of a monolithic concret...

Full description

Saved in:
Bibliographic Details
Main Author: Aldin Hosseini, Seyed Jamal
Format: Thesis
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/37965/5/SeyedJamalAldinMFKA2012.pdf
http://eprints.utm.my/id/eprint/37965/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.37965
record_format eprints
spelling my.utm.379652018-05-27T08:16:38Z http://eprints.utm.my/id/eprint/37965/ Effects of spiral on the bond stress-slip relationship in the splice sleeve connector Aldin Hosseini, Seyed Jamal TA Engineering (General). Civil engineering (General) Connections are defined as the system to transmit the forces among the precast element and provide the strength and ductility. Therefore, the connection system of the precast concrete structure must be designed in such way that its structural performance is equivalent to that of a monolithic concrete structure. Connections can exactly be as the critical points of a precast concrete structure especially when it involves in the aspect of bonding between reinforcement and concrete. Current study evaluates the relationship of the bond stress-slip of reinforcing bar joined by spliced sleeve connectors. Twenty one specimens in which three of them were control specimen with different variables such as pitch distance and spiral diameter. Those splice sleeve connectors utilized mild steel pipe, spiral surrounding the main bar and four steel bars as a shear keys that were welded into the inner surface of steel pipe. All the specimens were filled with Sika grout 215 and tested under incrementally tensile load. The experimental tests examined the bond stress, slip and failure modes. The results suggest that reducing the pitch distance and spiral diameter of spiral lead to higher ultimate bond stress. Also, the splice sleeve connector with pitch distance of 25mm contributed to the ultimate bond stress with lower amplitude of slip. It means that the pitch distance of 25mm has the main role to control the range of slip in comparison with the others. Thus, using the spiral with a smaller pitch distance will give the best performance of the splices sleeve connector. 2012-01 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/37965/5/SeyedJamalAldinMFKA2012.pdf Aldin Hosseini, Seyed Jamal (2012) Effects of spiral on the bond stress-slip relationship in the splice sleeve connector. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Aldin Hosseini, Seyed Jamal
Effects of spiral on the bond stress-slip relationship in the splice sleeve connector
description Connections are defined as the system to transmit the forces among the precast element and provide the strength and ductility. Therefore, the connection system of the precast concrete structure must be designed in such way that its structural performance is equivalent to that of a monolithic concrete structure. Connections can exactly be as the critical points of a precast concrete structure especially when it involves in the aspect of bonding between reinforcement and concrete. Current study evaluates the relationship of the bond stress-slip of reinforcing bar joined by spliced sleeve connectors. Twenty one specimens in which three of them were control specimen with different variables such as pitch distance and spiral diameter. Those splice sleeve connectors utilized mild steel pipe, spiral surrounding the main bar and four steel bars as a shear keys that were welded into the inner surface of steel pipe. All the specimens were filled with Sika grout 215 and tested under incrementally tensile load. The experimental tests examined the bond stress, slip and failure modes. The results suggest that reducing the pitch distance and spiral diameter of spiral lead to higher ultimate bond stress. Also, the splice sleeve connector with pitch distance of 25mm contributed to the ultimate bond stress with lower amplitude of slip. It means that the pitch distance of 25mm has the main role to control the range of slip in comparison with the others. Thus, using the spiral with a smaller pitch distance will give the best performance of the splices sleeve connector.
format Thesis
author Aldin Hosseini, Seyed Jamal
author_facet Aldin Hosseini, Seyed Jamal
author_sort Aldin Hosseini, Seyed Jamal
title Effects of spiral on the bond stress-slip relationship in the splice sleeve connector
title_short Effects of spiral on the bond stress-slip relationship in the splice sleeve connector
title_full Effects of spiral on the bond stress-slip relationship in the splice sleeve connector
title_fullStr Effects of spiral on the bond stress-slip relationship in the splice sleeve connector
title_full_unstemmed Effects of spiral on the bond stress-slip relationship in the splice sleeve connector
title_sort effects of spiral on the bond stress-slip relationship in the splice sleeve connector
publishDate 2012
url http://eprints.utm.my/id/eprint/37965/5/SeyedJamalAldinMFKA2012.pdf
http://eprints.utm.my/id/eprint/37965/
_version_ 1643650196379271168