Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru

The design of the sanitary sewer or a treatment plant needs the assessment of the extent of extraneous water that seeps into the system. The study provides the appropriateness of some of the design parameters used by the local engineers. Particular attention is also given to the variation of inflow...

Full description

Saved in:
Bibliographic Details
Main Author: Kamran, Kamran
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/id/eprint/3801/1/KamranMFKA2005.pdf
http://eprints.utm.my/id/eprint/3801/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.3801
record_format eprints
spelling my.utm.38012018-01-10T07:37:11Z http://eprints.utm.my/id/eprint/3801/ Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru Kamran, Kamran TA Engineering (General). Civil engineering (General) The design of the sanitary sewer or a treatment plant needs the assessment of the extent of extraneous water that seeps into the system. The study provides the appropriateness of some of the design parameters used by the local engineers. Particular attention is also given to the variation of inflow / infiltration with respect to rainfall occurrence which is found to be very large. The data used in making the evaluation is obtained using the flow-meters for directly measuring the flow in a running sewer line in two different residential areas in ten phases which include both weekdays and weekends, collecting and measuring the amount of water trapped in an abandoned sewer line (field model) continuously for nearly eight months which include both dry and wet periods and also by performing infiltration tests on a laboratory model under saturated and unsaturated conditions to obtain the results in controlled environment. The rainfall is measured using automatic rain-gauge. The results show that the infiltration into the sewers much higher than allowable under Malaysian Standards and infiltration as high as 275.46 liters/day/km-length/mmdiameter is found during wet period. Laboratory tests show results within allowable limits. Based on site study, the design parameters of per capita flow contribution and peak flow factor are found lower than the Malaysian Standard. The results thus obtained are going to be helpful for the municipal agencies and their consulting engineers quantify and simulate rainfall derived infiltration and inflow that affects the sewer systems they design, operate and manage. 2005-10 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/3801/1/KamranMFKA2005.pdf Kamran, Kamran (2005) Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Kamran, Kamran
Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru
description The design of the sanitary sewer or a treatment plant needs the assessment of the extent of extraneous water that seeps into the system. The study provides the appropriateness of some of the design parameters used by the local engineers. Particular attention is also given to the variation of inflow / infiltration with respect to rainfall occurrence which is found to be very large. The data used in making the evaluation is obtained using the flow-meters for directly measuring the flow in a running sewer line in two different residential areas in ten phases which include both weekdays and weekends, collecting and measuring the amount of water trapped in an abandoned sewer line (field model) continuously for nearly eight months which include both dry and wet periods and also by performing infiltration tests on a laboratory model under saturated and unsaturated conditions to obtain the results in controlled environment. The rainfall is measured using automatic rain-gauge. The results show that the infiltration into the sewers much higher than allowable under Malaysian Standards and infiltration as high as 275.46 liters/day/km-length/mmdiameter is found during wet period. Laboratory tests show results within allowable limits. Based on site study, the design parameters of per capita flow contribution and peak flow factor are found lower than the Malaysian Standard. The results thus obtained are going to be helpful for the municipal agencies and their consulting engineers quantify and simulate rainfall derived infiltration and inflow that affects the sewer systems they design, operate and manage.
format Thesis
author Kamran, Kamran
author_facet Kamran, Kamran
author_sort Kamran, Kamran
title Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru
title_short Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru
title_full Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru
title_fullStr Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru
title_full_unstemmed Evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in Skudai, Johor Bahru
title_sort evaluation of inflow/infiltration and flow characteristics for design of sanitary sewers in skudai, johor bahru
publishDate 2005
url http://eprints.utm.my/id/eprint/3801/1/KamranMFKA2005.pdf
http://eprints.utm.my/id/eprint/3801/
_version_ 1643643894479454208