Eccentrically loaded externally confined HSC columns
The application of steel-straps confinement has been proven to be effective in increasing the strength and ductility of High-Strength Concrete (HSC) column comparable to Fiber-Reinforced Polymer. However, most of the research of confined HSC column has mainly concentrated on concentric loading. In a...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2013
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/39191/ https://www.researchgate.net/publication/259497224_Eccentrically_Loaded_Externally_Confined_HSC_Columns |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.39191 |
---|---|
record_format |
eprints |
spelling |
my.utm.391912017-09-28T03:36:30Z http://eprints.utm.my/id/eprint/39191/ Eccentrically loaded externally confined HSC columns Ma, Chow Khun Awang, Abdullah Zawawi Omar, Wahid TA Engineering (General). Civil engineering (General) The application of steel-straps confinement has been proven to be effective in increasing the strength and ductility of High-Strength Concrete (HSC) column comparable to Fiber-Reinforced Polymer. However, most of the research of confined HSC column has mainly concentrated on concentric loading. In actual practical condition, most of the columns are subjected to eccentric loading. The scarcity of the experimental data for eccentric loaded confined HSC column has prevented the potential use of this type of structure element. In this paper, five short HSC columns were tested. The specimens were confined with steel-straps and tested with 25mm and 50 mm eccentric loading. The results show that steel-straps confinement increases the strength and deformability of high-strength concrete column, although the confinement effects in eccentrically loaded columns are not as pronounces as concentrically loaded column. 2013 Conference or Workshop Item PeerReviewed Ma, Chow Khun and Awang, Abdullah Zawawi and Omar, Wahid (2013) Eccentrically loaded externally confined HSC columns. In: GEOCON 2013, 2013. https://www.researchgate.net/publication/259497224_Eccentrically_Loaded_Externally_Confined_HSC_Columns |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Ma, Chow Khun Awang, Abdullah Zawawi Omar, Wahid Eccentrically loaded externally confined HSC columns |
description |
The application of steel-straps confinement has been proven to be effective in increasing the strength and ductility of High-Strength Concrete (HSC) column comparable to Fiber-Reinforced Polymer. However, most of the research of confined HSC column has mainly concentrated on concentric loading. In actual practical condition, most of the columns are subjected to eccentric loading. The scarcity of the experimental data for eccentric loaded confined HSC column has prevented the potential use of this type of structure element. In this paper, five short HSC columns were tested. The specimens were confined with steel-straps and tested with 25mm and 50 mm eccentric loading. The results show that steel-straps confinement increases the strength and deformability of high-strength concrete column, although the confinement effects in eccentrically loaded columns are not as pronounces as concentrically loaded column. |
format |
Conference or Workshop Item |
author |
Ma, Chow Khun Awang, Abdullah Zawawi Omar, Wahid |
author_facet |
Ma, Chow Khun Awang, Abdullah Zawawi Omar, Wahid |
author_sort |
Ma, Chow Khun |
title |
Eccentrically loaded externally confined HSC columns |
title_short |
Eccentrically loaded externally confined HSC columns |
title_full |
Eccentrically loaded externally confined HSC columns |
title_fullStr |
Eccentrically loaded externally confined HSC columns |
title_full_unstemmed |
Eccentrically loaded externally confined HSC columns |
title_sort |
eccentrically loaded externally confined hsc columns |
publishDate |
2013 |
url |
http://eprints.utm.my/id/eprint/39191/ https://www.researchgate.net/publication/259497224_Eccentrically_Loaded_Externally_Confined_HSC_Columns |
_version_ |
1643650313164423168 |