Push tests on innovative shear connector for composite beam with cold-formed steel section
In this study, experimental tests were conducted to investigate the ductility and strength capacity of new shear connector. Push test specimens were prepared and tested according to EN1994-1-1 standard. The push test specimen consists of two cold-formed steel lipped channel sections oriented back-to...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
2012
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/47432/ http://scholarsmine.mst.edu/cgi/viewcontent.cgi?article=1840&context=isccss |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Summary: | In this study, experimental tests were conducted to investigate the ductility and strength capacity of new shear connector. Push test specimens were prepared and tested according to EN1994-1-1 standard. The push test specimen consists of two cold-formed steel lipped channel sections oriented back-to-back to form an I-section beam, transverse metal deck and normal concrete slabs grade C25/30. Angle brackets were obtained from the same section of the beam and fastened to the web of steel beam to provide the shear connection. Two shear connectors were tested namely; “SC1” and “SC2” shear connectors. Both shear connectors showed a ductile behavior and had satisfied the ductility requirements of EN1994-1-1 standard. It was concluded that the ductile behavior of shear connectors could enhance the design of composite beam. |
---|