Temperature sensor placement for multiple fault detection
Sensors play a very important role in all kind of industrial plant. Types of sensor can vary from level, flow, pressure and temperature. In an industrial plant, a huge quantity of sensors are being installed for monitoring purpose. These sensors involve complex installation architecture due to cable...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/48633/1/MatthewLeeHsienLoongMFKE2014.pdf http://eprints.utm.my/id/eprint/48633/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:81879?queryType=vitalDismax&query=Temperature+sensor+placement+for+multiple+fault+detection&public=true |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.48633 |
---|---|
record_format |
eprints |
spelling |
my.utm.486332020-03-04T08:19:44Z http://eprints.utm.my/id/eprint/48633/ Temperature sensor placement for multiple fault detection Lee, Matthew Hsien Loong TA Engineering (General). Civil engineering (General) Sensors play a very important role in all kind of industrial plant. Types of sensor can vary from level, flow, pressure and temperature. In an industrial plant, a huge quantity of sensors are being installed for monitoring purpose. These sensors involve complex installation architecture due to cable and installation cost. Each and every single sensor only detects a single fault. In industrial plant, pipeline plays a very important role in ferrying chemical fluids around and across the plant. In order to secure the quality, quantity and safety of the pipeline, all type of sensors are being installed to monitor the chemical fluids in the pipeline. This research paper aims to develop a desired simulation where the best location of sensor placement optimization for multiple faults detection using Fuzzy method. Fault will include vary problems such as temperature below or above limit at the inflow and outflow of the pipe and the pipe leakage. This will provide a fault detection and give a warning signal to the operator. From the above method being applied, the complexity architecture of the system and installation cost can be reduced in every industrial plant. It can also be environmental friendly as less resource is being used to establish the system for the industrial plant. 2014 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/48633/1/MatthewLeeHsienLoongMFKE2014.pdf Lee, Matthew Hsien Loong (2014) Temperature sensor placement for multiple fault detection. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:81879?queryType=vitalDismax&query=Temperature+sensor+placement+for+multiple+fault+detection&public=true |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Lee, Matthew Hsien Loong Temperature sensor placement for multiple fault detection |
description |
Sensors play a very important role in all kind of industrial plant. Types of sensor can vary from level, flow, pressure and temperature. In an industrial plant, a huge quantity of sensors are being installed for monitoring purpose. These sensors involve complex installation architecture due to cable and installation cost. Each and every single sensor only detects a single fault. In industrial plant, pipeline plays a very important role in ferrying chemical fluids around and across the plant. In order to secure the quality, quantity and safety of the pipeline, all type of sensors are being installed to monitor the chemical fluids in the pipeline. This research paper aims to develop a desired simulation where the best location of sensor placement optimization for multiple faults detection using Fuzzy method. Fault will include vary problems such as temperature below or above limit at the inflow and outflow of the pipe and the pipe leakage. This will provide a fault detection and give a warning signal to the operator. From the above method being applied, the complexity architecture of the system and installation cost can be reduced in every industrial plant. It can also be environmental friendly as less resource is being used to establish the system for the industrial plant. |
format |
Thesis |
author |
Lee, Matthew Hsien Loong |
author_facet |
Lee, Matthew Hsien Loong |
author_sort |
Lee, Matthew Hsien Loong |
title |
Temperature sensor placement for multiple fault detection |
title_short |
Temperature sensor placement for multiple fault detection |
title_full |
Temperature sensor placement for multiple fault detection |
title_fullStr |
Temperature sensor placement for multiple fault detection |
title_full_unstemmed |
Temperature sensor placement for multiple fault detection |
title_sort |
temperature sensor placement for multiple fault detection |
publishDate |
2014 |
url |
http://eprints.utm.my/id/eprint/48633/1/MatthewLeeHsienLoongMFKE2014.pdf http://eprints.utm.my/id/eprint/48633/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:81879?queryType=vitalDismax&query=Temperature+sensor+placement+for+multiple+fault+detection&public=true |
_version_ |
1662754262205071360 |