Tracking performance and disturbance rejection of pneumatic actuator system

This paper investigates several control strategies that potential to perform well in regulating and tracking set point of pneumatic actuator system and able to reject disturbance. The system consists of 5-port proportional valve with the dead-band flow and double rod cylinders that exhibit significa...

Full description

Saved in:
Bibliographic Details
Main Authors: Salim, S. N. S., Ismail, Z. H., Rahmat, M. F., Faudzi, A. A. M., Sunar, N. H., Samsudin, S. I.
Format: Conference or Workshop Item
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/51377/
http://dx.doi.org/10.1109/ASCC.2013.6606083
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.51377
record_format eprints
spelling my.utm.513772017-09-18T01:52:32Z http://eprints.utm.my/id/eprint/51377/ Tracking performance and disturbance rejection of pneumatic actuator system Salim, S. N. S. Ismail, Z. H. Rahmat, M. F. Faudzi, A. A. M. Sunar, N. H. Samsudin, S. I. TK Electrical engineering. Electronics Nuclear engineering This paper investigates several control strategies that potential to perform well in regulating and tracking set point of pneumatic actuator system and able to reject disturbance. The system consists of 5-port proportional valve with the dead-band flow and double rod cylinders that exhibit significant friction. Two control strategies of PID and NPID controllers with four different configurations with and without dead-zone compensators (DZC) are simulated. Three different input signals including step, sinusoidal and random waveforms are used to evaluate the performance of the proposed techniques. The effectiveness of NPID+DZC has been successfully demonstrated and proved through simulation and experimental studies. 2013 Conference or Workshop Item PeerReviewed Salim, S. N. S. and Ismail, Z. H. and Rahmat, M. F. and Faudzi, A. A. M. and Sunar, N. H. and Samsudin, S. I. (2013) Tracking performance and disturbance rejection of pneumatic actuator system. In: 2013 9th Asian Control Conference, ASCC 2013. http://dx.doi.org/10.1109/ASCC.2013.6606083
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Salim, S. N. S.
Ismail, Z. H.
Rahmat, M. F.
Faudzi, A. A. M.
Sunar, N. H.
Samsudin, S. I.
Tracking performance and disturbance rejection of pneumatic actuator system
description This paper investigates several control strategies that potential to perform well in regulating and tracking set point of pneumatic actuator system and able to reject disturbance. The system consists of 5-port proportional valve with the dead-band flow and double rod cylinders that exhibit significant friction. Two control strategies of PID and NPID controllers with four different configurations with and without dead-zone compensators (DZC) are simulated. Three different input signals including step, sinusoidal and random waveforms are used to evaluate the performance of the proposed techniques. The effectiveness of NPID+DZC has been successfully demonstrated and proved through simulation and experimental studies.
format Conference or Workshop Item
author Salim, S. N. S.
Ismail, Z. H.
Rahmat, M. F.
Faudzi, A. A. M.
Sunar, N. H.
Samsudin, S. I.
author_facet Salim, S. N. S.
Ismail, Z. H.
Rahmat, M. F.
Faudzi, A. A. M.
Sunar, N. H.
Samsudin, S. I.
author_sort Salim, S. N. S.
title Tracking performance and disturbance rejection of pneumatic actuator system
title_short Tracking performance and disturbance rejection of pneumatic actuator system
title_full Tracking performance and disturbance rejection of pneumatic actuator system
title_fullStr Tracking performance and disturbance rejection of pneumatic actuator system
title_full_unstemmed Tracking performance and disturbance rejection of pneumatic actuator system
title_sort tracking performance and disturbance rejection of pneumatic actuator system
publishDate 2013
url http://eprints.utm.my/id/eprint/51377/
http://dx.doi.org/10.1109/ASCC.2013.6606083
_version_ 1643653022351360000