Characterization of a low NOx flameless combustion burner using natural gas

Flameless combustion is a method that has a great potential in reducing pollutant emission from combustion process. In this work, the operation and emission of a laboratory scale furnace under the flameless combustion regime using natural gas as a fuel was examined. In the experimental setup, the co...

Full description

Saved in:
Bibliographic Details
Main Authors: Abuelnuor, Abdeen Ali, Abdul Wahid, Mazlan, Saat, Aminuddin, Osman, Mai A. R.
Format: Article
Language:English
Published: Penerbit UTM 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/52096/1/AbdeenAliAbuelnuor2014_Characterizationofalow.pdf
http://eprints.utm.my/id/eprint/52096/
http://dx.doi.org/10.11113/jt.v66.2497
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.52096
record_format eprints
spelling my.utm.520962018-09-17T03:47:11Z http://eprints.utm.my/id/eprint/52096/ Characterization of a low NOx flameless combustion burner using natural gas Abuelnuor, Abdeen Ali Abdul Wahid, Mazlan Saat, Aminuddin Osman, Mai A. R. TJ Mechanical engineering and machinery Flameless combustion is a method that has a great potential in reducing pollutant emission from combustion process. In this work, the operation and emission of a laboratory scale furnace under the flameless combustion regime using natural gas as a fuel was examined. In the experimental setup, the combustor was equipped with parallel jet burner systems with controlled gas fuel and oxidizer. Several ports have been integrated in the combustor to allow for temperature and combustion emission measurement. In the study, a comparison between flameless combustion with and without preheated combustion air has been made. The atmospheric air was heated to near the auto ignition temperature by a coil placed within the furnace assembly. The results show that flameless combustion mode could be obtained with and without preheated combustion air. The results also revealed that the laboratory scale furnace could successfully operate in flameless combustion regime using natural gas as fuel. In terms of emission, it was found that flameless combustion was more effective than the conventional combustion in reducing the rate of NOX emission Penerbit UTM 2014 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/52096/1/AbdeenAliAbuelnuor2014_Characterizationofalow.pdf Abuelnuor, Abdeen Ali and Abdul Wahid, Mazlan and Saat, Aminuddin and Osman, Mai A. R. (2014) Characterization of a low NOx flameless combustion burner using natural gas. Jurnal Teknologi (Sciences and Engineering), 66 (2). pp. 121-125. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v66.2497 DOI: 10.11113/jt.v66.2497
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Abuelnuor, Abdeen Ali
Abdul Wahid, Mazlan
Saat, Aminuddin
Osman, Mai A. R.
Characterization of a low NOx flameless combustion burner using natural gas
description Flameless combustion is a method that has a great potential in reducing pollutant emission from combustion process. In this work, the operation and emission of a laboratory scale furnace under the flameless combustion regime using natural gas as a fuel was examined. In the experimental setup, the combustor was equipped with parallel jet burner systems with controlled gas fuel and oxidizer. Several ports have been integrated in the combustor to allow for temperature and combustion emission measurement. In the study, a comparison between flameless combustion with and without preheated combustion air has been made. The atmospheric air was heated to near the auto ignition temperature by a coil placed within the furnace assembly. The results show that flameless combustion mode could be obtained with and without preheated combustion air. The results also revealed that the laboratory scale furnace could successfully operate in flameless combustion regime using natural gas as fuel. In terms of emission, it was found that flameless combustion was more effective than the conventional combustion in reducing the rate of NOX emission
format Article
author Abuelnuor, Abdeen Ali
Abdul Wahid, Mazlan
Saat, Aminuddin
Osman, Mai A. R.
author_facet Abuelnuor, Abdeen Ali
Abdul Wahid, Mazlan
Saat, Aminuddin
Osman, Mai A. R.
author_sort Abuelnuor, Abdeen Ali
title Characterization of a low NOx flameless combustion burner using natural gas
title_short Characterization of a low NOx flameless combustion burner using natural gas
title_full Characterization of a low NOx flameless combustion burner using natural gas
title_fullStr Characterization of a low NOx flameless combustion burner using natural gas
title_full_unstemmed Characterization of a low NOx flameless combustion burner using natural gas
title_sort characterization of a low nox flameless combustion burner using natural gas
publisher Penerbit UTM
publishDate 2014
url http://eprints.utm.my/id/eprint/52096/1/AbdeenAliAbuelnuor2014_Characterizationofalow.pdf
http://eprints.utm.my/id/eprint/52096/
http://dx.doi.org/10.11113/jt.v66.2497
_version_ 1643653151001149440