Gas hold-up profiles determination by means of ultrasonic transducer
This paper details a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic transducer. The gas hold-up profiles from 1.85 mm to 7.7 mm diameter are of interest in this investigation. The measurement setup consist of ultrasonic transducer, an experimental colu...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM
2014
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/52958/1/RuzairiAbdulRahim2014_Gashold-upprofilesdetermination.pdf http://eprints.utm.my/id/eprint/52958/ http://dx.doi.org/10.11113/jt.v69.3300 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.52958 |
---|---|
record_format |
eprints |
spelling |
my.utm.529582018-07-19T07:22:25Z http://eprints.utm.my/id/eprint/52958/ Gas hold-up profiles determination by means of ultrasonic transducer Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi Abdul Rahim, Herlina Zakaria, Zulkarnay Pusppanathan, Muhammad Jaysuman Loon, Goh Chiew Ahmad, Nasarudin Wahab, Yasmin Abdul Rahman, Fazlul TK Electrical engineering. Electronics Nuclear engineering This paper details a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic transducer. The gas hold-up profiles from 1.85 mm to 7.7 mm diameter are of interest in this investigation. The measurement setup consist of ultrasonic transducer, an experimental column, signal conditioning circuit, and a digital storage oscilloscope. The experiment was conducted using several gas hold-up profiles and the relationship between the ultrasonic amplitude and the profile were deduced. A finite element analysis was carried out to further verify the results. This paper explains how one could use ultrasonic transducer to estimate the gas hold-up profiles in a liquid column. Penerbit UTM 2014 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/52958/1/RuzairiAbdulRahim2014_Gashold-upprofilesdetermination.pdf Fazalul Rahiman, Mohd. Hafiz and Abdul Rahim, Ruzairi and Abdul Rahim, Herlina and Zakaria, Zulkarnay and Pusppanathan, Muhammad Jaysuman and Loon, Goh Chiew and Ahmad, Nasarudin and Wahab, Yasmin Abdul and Rahman, Fazlul (2014) Gas hold-up profiles determination by means of ultrasonic transducer. Jurnal Teknologi (Sciences and Engineering), 69 (8). pp. 81-84. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v69.3300 DOI: 10.11113/jt.v69.3300 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi Abdul Rahim, Herlina Zakaria, Zulkarnay Pusppanathan, Muhammad Jaysuman Loon, Goh Chiew Ahmad, Nasarudin Wahab, Yasmin Abdul Rahman, Fazlul Gas hold-up profiles determination by means of ultrasonic transducer |
description |
This paper details a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic transducer. The gas hold-up profiles from 1.85 mm to 7.7 mm diameter are of interest in this investigation. The measurement setup consist of ultrasonic transducer, an experimental column, signal conditioning circuit, and a digital storage oscilloscope. The experiment was conducted using several gas hold-up profiles and the relationship between the ultrasonic amplitude and the profile were deduced. A finite element analysis was carried out to further verify the results. This paper explains how one could use ultrasonic transducer to estimate the gas hold-up profiles in a liquid column. |
format |
Article |
author |
Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi Abdul Rahim, Herlina Zakaria, Zulkarnay Pusppanathan, Muhammad Jaysuman Loon, Goh Chiew Ahmad, Nasarudin Wahab, Yasmin Abdul Rahman, Fazlul |
author_facet |
Fazalul Rahiman, Mohd. Hafiz Abdul Rahim, Ruzairi Abdul Rahim, Herlina Zakaria, Zulkarnay Pusppanathan, Muhammad Jaysuman Loon, Goh Chiew Ahmad, Nasarudin Wahab, Yasmin Abdul Rahman, Fazlul |
author_sort |
Fazalul Rahiman, Mohd. Hafiz |
title |
Gas hold-up profiles determination by means of ultrasonic transducer |
title_short |
Gas hold-up profiles determination by means of ultrasonic transducer |
title_full |
Gas hold-up profiles determination by means of ultrasonic transducer |
title_fullStr |
Gas hold-up profiles determination by means of ultrasonic transducer |
title_full_unstemmed |
Gas hold-up profiles determination by means of ultrasonic transducer |
title_sort |
gas hold-up profiles determination by means of ultrasonic transducer |
publisher |
Penerbit UTM |
publishDate |
2014 |
url |
http://eprints.utm.my/id/eprint/52958/1/RuzairiAbdulRahim2014_Gashold-upprofilesdetermination.pdf http://eprints.utm.my/id/eprint/52958/ http://dx.doi.org/10.11113/jt.v69.3300 |
_version_ |
1643653288785084416 |