Optimization of the paper permeability tester using Robust design
This paper is using practical case study of robust design engineering. Effect of control factors and optimum condition is studied to design a more robust Paper Permeability Tester. In this study, robustness means decreasing uncertainty that is validity of measurement results with the Tester. Robustn...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM
2014
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/54377/1/RozzetaDolah2014_Optimizationofthepaperpermeability.pdf http://eprints.utm.my/id/eprint/54377/ http://dx.doi.org/10.11113/jt.v68.3004 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.54377 |
---|---|
record_format |
eprints |
spelling |
my.utm.543772018-08-12T03:49:27Z http://eprints.utm.my/id/eprint/54377/ Optimization of the paper permeability tester using Robust design Watanabe, Kazunori Miyagi, Zenichi Dolah, Rozzeta Takahashi, K. T Technology This paper is using practical case study of robust design engineering. Effect of control factors and optimum condition is studied to design a more robust Paper Permeability Tester. In this study, robustness means decreasing uncertainty that is validity of measurement results with the Tester. Robustness is required to ensure the reliabilityfor the measurement results in the field of the measurement tester. Thus, orthogonal array L18 is employed and the optimum condition was obtained for decreasing the measurement dispersion. Experiment reproducibility of Signal-to-Noise Ratio and sensitivity were confirmed within 20%. SNR value is linearly depends on air permeance value. When the value of air permeance is small, it tends to provide small SNR. Flow rate in nozzle was considered as a major cause. Stability of flow in the nozzle is significant to design the Tester to be more robustness.In a case of a flow under the rapidly, SNR is small due unstable flow. Sensitivity with nozzle diameter was dramatically large. Nozzle specification tolerance wasfound to have strong influence on measurement result Penerbit UTM 2014 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/54377/1/RozzetaDolah2014_Optimizationofthepaperpermeability.pdf Watanabe, Kazunori and Miyagi, Zenichi and Dolah, Rozzeta and Takahashi, K. (2014) Optimization of the paper permeability tester using Robust design. Jurnal Teknologi (Sciences and Engineering), 68 (4). pp. 91-96. ISSN 0127-9696 http://dx.doi.org/10.11113/jt.v68.3004 DOI: 10.11113/jt.v68.3004 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
T Technology |
spellingShingle |
T Technology Watanabe, Kazunori Miyagi, Zenichi Dolah, Rozzeta Takahashi, K. Optimization of the paper permeability tester using Robust design |
description |
This paper is using practical case study of robust design engineering. Effect of control factors and optimum condition is studied to design a more robust Paper Permeability Tester. In this study, robustness means decreasing uncertainty that is validity of measurement results with the Tester. Robustness is required to ensure the reliabilityfor the measurement results in the field of the measurement tester. Thus, orthogonal array L18 is employed and the optimum condition was obtained for decreasing the measurement dispersion. Experiment reproducibility of Signal-to-Noise Ratio and sensitivity were confirmed within 20%. SNR value is linearly depends on air permeance value. When the value of air permeance is small, it tends to provide small SNR. Flow rate in nozzle was considered as a major cause. Stability of flow in the nozzle is significant to design the Tester to be more robustness.In a case of a flow under the rapidly, SNR is small due unstable flow. Sensitivity with nozzle diameter was dramatically large. Nozzle specification tolerance wasfound to have strong influence on measurement result |
format |
Article |
author |
Watanabe, Kazunori Miyagi, Zenichi Dolah, Rozzeta Takahashi, K. |
author_facet |
Watanabe, Kazunori Miyagi, Zenichi Dolah, Rozzeta Takahashi, K. |
author_sort |
Watanabe, Kazunori |
title |
Optimization of the paper permeability tester using Robust design |
title_short |
Optimization of the paper permeability tester using Robust design |
title_full |
Optimization of the paper permeability tester using Robust design |
title_fullStr |
Optimization of the paper permeability tester using Robust design |
title_full_unstemmed |
Optimization of the paper permeability tester using Robust design |
title_sort |
optimization of the paper permeability tester using robust design |
publisher |
Penerbit UTM |
publishDate |
2014 |
url |
http://eprints.utm.my/id/eprint/54377/1/RozzetaDolah2014_Optimizationofthepaperpermeability.pdf http://eprints.utm.my/id/eprint/54377/ http://dx.doi.org/10.11113/jt.v68.3004 |
_version_ |
1643653515289034752 |