Emission factor establishment for palm oil mill boiler
A study to establish the total particulate emission factor (EFs) from boiler of a palm oil mill plant equipped with a multi-cyclones particulate arrestor was performed and reported in this research. The mill employs a 500 kg steam/ h capacity of water-tube typed boiler and processes 60 tonnes per ho...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor's University
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/54973/1/NurHHanafi2016_EmissionFactorEstablishmentforPalmOil.pdf http://eprints.utm.my/id/eprint/54973/ https://www.scopus.com/record/display.uri?eid=2-s2.0-84988422231&origin=inward&txGid=dc6871be5549c1c61052f63e44d1b63a |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.54973 |
---|---|
record_format |
eprints |
spelling |
my.utm.549732017-11-21T00:37:00Z http://eprints.utm.my/id/eprint/54973/ Emission factor establishment for palm oil mill boiler Hanafi, Nur H. Hassim, Mimi Haryani Yusuf, Mohd. R. M. TP Chemical technology A study to establish the total particulate emission factor (EFs) from boiler of a palm oil mill plant equipped with a multi-cyclones particulate arrestor was performed and reported in this research. The mill employs a 500 kg steam/ h capacity of water-tube typed boiler and processes 60 tonnes per hour of fresh fruit bunch (FFB). The samples of the dust were collected iso-kinetically using the USEPA method 17 sampling train through a sampling port located after a multidust cyclone unit. Results showed that the total dust generated from the boiler is 62.15 g/s and the calculated total dust emission factor based on the boiler capacity is 7.46 g/kg. Poor combustion process is among the main factor that leads to the high particulate emission. EFs data allows for early prediction of pollutants emission, which subsequently will assist in determining the degree of control and the air pollution control system needed, besides evaluating the effectiveness of the existing pollution control strategies. The establishment of EFs for palm oil mills will definitely bring benefits for a better management of health and safety risks in palm oil mills, now and in the future. Taylor's University 2015 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/54973/1/NurHHanafi2016_EmissionFactorEstablishmentforPalmOil.pdf Hanafi, Nur H. and Hassim, Mimi Haryani and Yusuf, Mohd. R. M. (2015) Emission factor establishment for palm oil mill boiler. Journal of Engineering Science and Technology, 10 (4). pp. 50-60. ISSN 1823-4690 https://www.scopus.com/record/display.uri?eid=2-s2.0-84988422231&origin=inward&txGid=dc6871be5549c1c61052f63e44d1b63a |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TP Chemical technology |
spellingShingle |
TP Chemical technology Hanafi, Nur H. Hassim, Mimi Haryani Yusuf, Mohd. R. M. Emission factor establishment for palm oil mill boiler |
description |
A study to establish the total particulate emission factor (EFs) from boiler of a palm oil mill plant equipped with a multi-cyclones particulate arrestor was performed and reported in this research. The mill employs a 500 kg steam/ h capacity of water-tube typed boiler and processes 60 tonnes per hour of fresh fruit bunch (FFB). The samples of the dust were collected iso-kinetically using the USEPA method 17 sampling train through a sampling port located after a multidust cyclone unit. Results showed that the total dust generated from the boiler is 62.15 g/s and the calculated total dust emission factor based on the boiler capacity is 7.46 g/kg. Poor combustion process is among the main factor that leads to the high particulate emission. EFs data allows for early prediction of pollutants emission, which subsequently will assist in determining the degree of control and the air pollution control system needed, besides evaluating the effectiveness of the existing pollution control strategies. The establishment of EFs for palm oil mills will definitely bring benefits for a better management of health and safety risks in palm oil mills, now and in the future. |
format |
Article |
author |
Hanafi, Nur H. Hassim, Mimi Haryani Yusuf, Mohd. R. M. |
author_facet |
Hanafi, Nur H. Hassim, Mimi Haryani Yusuf, Mohd. R. M. |
author_sort |
Hanafi, Nur H. |
title |
Emission factor establishment for palm oil mill boiler |
title_short |
Emission factor establishment for palm oil mill boiler |
title_full |
Emission factor establishment for palm oil mill boiler |
title_fullStr |
Emission factor establishment for palm oil mill boiler |
title_full_unstemmed |
Emission factor establishment for palm oil mill boiler |
title_sort |
emission factor establishment for palm oil mill boiler |