Characterization of total particulate emission for palm oil mill boiler
In Malaysia, more than four million hectares of land is used for oil palm cultivation. Malaysia palm oil industry has grown to become a very important biomass-based industry. This study investigates the emission from a palm waste biomass fired boiler of two studied palm oil mill plants - named as Pl...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Italian Association of Chemical Engineering - AIDIC
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/58041/ http://dx.doi.org/10.3303/CET1545243 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.58041 |
---|---|
record_format |
eprints |
spelling |
my.utm.580412022-04-05T07:11:14Z http://eprints.utm.my/id/eprint/58041/ Characterization of total particulate emission for palm oil mill boiler Hanafi, Nur H. Hassim, Mimi Haryani Mokhtar, Mutahharah M. Yusuf, Mohd. R. M. TP Chemical technology In Malaysia, more than four million hectares of land is used for oil palm cultivation. Malaysia palm oil industry has grown to become a very important biomass-based industry. This study investigates the emission from a palm waste biomass fired boiler of two studied palm oil mill plants - named as Plant A and Plant B. The finding shows that the total particulate emission of Plant A is 4,242 mg/Nm3-exceeding the emission limit specified by the Department of Environment Malaysia (DOE) by 960 %, while the average total particulate emission of Plant B was 851 mg/Nm3 (exceeds the limit by 113 %). This study also performed more detailed measurements on the emissions of PM10 and PM2.5 in Plant B. It was found that the emitted PM10 and PM2.5 is not significant compared to the total particulate emission in this plant, since both are less than 20 % of the total particulate emission. Italian Association of Chemical Engineering - AIDIC 2015 Article PeerReviewed Hanafi, Nur H. and Hassim, Mimi Haryani and Mokhtar, Mutahharah M. and Yusuf, Mohd. R. M. (2015) Characterization of total particulate emission for palm oil mill boiler. Chemical Engineering Transactions, 45 . pp. 1453-1458. ISSN 2283-9216 http://dx.doi.org/10.3303/CET1545243 DOI:10.3303/CET1545243 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TP Chemical technology |
spellingShingle |
TP Chemical technology Hanafi, Nur H. Hassim, Mimi Haryani Mokhtar, Mutahharah M. Yusuf, Mohd. R. M. Characterization of total particulate emission for palm oil mill boiler |
description |
In Malaysia, more than four million hectares of land is used for oil palm cultivation. Malaysia palm oil industry has grown to become a very important biomass-based industry. This study investigates the emission from a palm waste biomass fired boiler of two studied palm oil mill plants - named as Plant A and Plant B. The finding shows that the total particulate emission of Plant A is 4,242 mg/Nm3-exceeding the emission limit specified by the Department of Environment Malaysia (DOE) by 960 %, while the average total particulate emission of Plant B was 851 mg/Nm3 (exceeds the limit by 113 %). This study also performed more detailed measurements on the emissions of PM10 and PM2.5 in Plant B. It was found that the emitted PM10 and PM2.5 is not significant compared to the total particulate emission in this plant, since both are less than 20 % of the total particulate emission. |
format |
Article |
author |
Hanafi, Nur H. Hassim, Mimi Haryani Mokhtar, Mutahharah M. Yusuf, Mohd. R. M. |
author_facet |
Hanafi, Nur H. Hassim, Mimi Haryani Mokhtar, Mutahharah M. Yusuf, Mohd. R. M. |
author_sort |
Hanafi, Nur H. |
title |
Characterization of total particulate emission for palm oil mill boiler |
title_short |
Characterization of total particulate emission for palm oil mill boiler |
title_full |
Characterization of total particulate emission for palm oil mill boiler |
title_fullStr |
Characterization of total particulate emission for palm oil mill boiler |
title_full_unstemmed |
Characterization of total particulate emission for palm oil mill boiler |
title_sort |
characterization of total particulate emission for palm oil mill boiler |
publisher |
Italian Association of Chemical Engineering - AIDIC |
publishDate |
2015 |
url |
http://eprints.utm.my/id/eprint/58041/ http://dx.doi.org/10.3303/CET1545243 |