Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane

In this work, a new variation of the electromembrane extraction (EME) approach employing a hollow polymer inclusion membrane (HPIM) was developed. In this method, a HPIM was prepared by casting a solution of the desired proportions of cellulose acetate (CTA), tris(2-ethylhexyl)phosphate (TEHP) and d...

Full description

Saved in:
Bibliographic Details
Main Authors: Mamat, Nor Akma, See, Hong Heng
Format: Article
Published: Elsevier 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/58277/
http://dx.doi.org/10.1016/j.chroma.2015.06.020
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.58277
record_format eprints
spelling my.utm.582772021-09-08T04:39:02Z http://eprints.utm.my/id/eprint/58277/ Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane Mamat, Nor Akma See, Hong Heng TP Chemical technology In this work, a new variation of the electromembrane extraction (EME) approach employing a hollow polymer inclusion membrane (HPIM) was developed. In this method, a HPIM was prepared by casting a solution of the desired proportions of cellulose acetate (CTA), tris(2-ethylhexyl)phosphate (TEHP) and di-(2-ethylhexyl)phosphoric acid (D2EHPA) in dichloromethane on glass capillary tubing. Three basic drugs namely amphetamine, methamphetamine, and 3,4-methylenedioxy- N-methylamphetamine (MDMA) were selected as model analytes to evaluate the extraction performance of this new approach. The drugs were extracted from human plasma samples, through a 20. µm thickness HPIM, to an aqueous acceptor solution inside the lumen of the hollow membrane. Parameters affecting the extraction efficiency were investigated in detail. Under the optimized conditions, enrichment factors in the range of 97-103-fold were obtained from 3. mL of sample solution with a 10. min extraction time and an applied voltage of 300. V across the HPIM. The detection limits of the method for the three drugs were in the range of 1.0-2.5. ng/mL (at a signal/noise ratio of three), with relative standard deviations of between 6.4% and 7.9%. When the method was applied to spiked plasma samples, the relative recoveries ranged from 99.2% to 100.8%. Enrichment factors of 103, 99 and 97 were obtained for amphetamine, methamphetamine, and MDMA, respectively. A comparison was also made between the newly developed approach and EME using supported liquid membranes (SLM) as well as standard sample preparation methods (liquid-liquid extraction) used by the Toxicology Unit, Department of Chemistry, Malaysia. Elsevier 2015 Article PeerReviewed Mamat, Nor Akma and See, Hong Heng (2015) Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane. Journal Of Chromatography A, 1406 . pp. 34-39. ISSN 0219-6352 http://dx.doi.org/10.1016/j.chroma.2015.06.020 DOI:10.1016/j.chroma.2015.06.020
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Mamat, Nor Akma
See, Hong Heng
Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
description In this work, a new variation of the electromembrane extraction (EME) approach employing a hollow polymer inclusion membrane (HPIM) was developed. In this method, a HPIM was prepared by casting a solution of the desired proportions of cellulose acetate (CTA), tris(2-ethylhexyl)phosphate (TEHP) and di-(2-ethylhexyl)phosphoric acid (D2EHPA) in dichloromethane on glass capillary tubing. Three basic drugs namely amphetamine, methamphetamine, and 3,4-methylenedioxy- N-methylamphetamine (MDMA) were selected as model analytes to evaluate the extraction performance of this new approach. The drugs were extracted from human plasma samples, through a 20. µm thickness HPIM, to an aqueous acceptor solution inside the lumen of the hollow membrane. Parameters affecting the extraction efficiency were investigated in detail. Under the optimized conditions, enrichment factors in the range of 97-103-fold were obtained from 3. mL of sample solution with a 10. min extraction time and an applied voltage of 300. V across the HPIM. The detection limits of the method for the three drugs were in the range of 1.0-2.5. ng/mL (at a signal/noise ratio of three), with relative standard deviations of between 6.4% and 7.9%. When the method was applied to spiked plasma samples, the relative recoveries ranged from 99.2% to 100.8%. Enrichment factors of 103, 99 and 97 were obtained for amphetamine, methamphetamine, and MDMA, respectively. A comparison was also made between the newly developed approach and EME using supported liquid membranes (SLM) as well as standard sample preparation methods (liquid-liquid extraction) used by the Toxicology Unit, Department of Chemistry, Malaysia.
format Article
author Mamat, Nor Akma
See, Hong Heng
author_facet Mamat, Nor Akma
See, Hong Heng
author_sort Mamat, Nor Akma
title Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
title_short Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
title_full Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
title_fullStr Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
title_full_unstemmed Development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
title_sort development and evaluation of electromembrane extraction across a hollow polymer inclusion membrane
publisher Elsevier
publishDate 2015
url http://eprints.utm.my/id/eprint/58277/
http://dx.doi.org/10.1016/j.chroma.2015.06.020