Peak-to-peak tracking method for measurement of optical path difference: Revisited

This paper reports on the measurement of optical path difference of spectral interference signal by using the peak-to-peak tracking method in the wavelength domain. Numerical simulations are performed to produce the interference spectrum based on an all fibre Mach-Zehnder interferometer with a white...

Full description

Saved in:
Bibliographic Details
Main Authors: Ley, H. H., Yahaya, A., Munajat, Y.
Format: Article
Published: Elsevier GmbH 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/58768/
http://www.dx.doi.org/10.1016/j.ijleo.2015.09.070
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.58768
record_format eprints
spelling my.utm.587682021-08-30T16:29:31Z http://eprints.utm.my/id/eprint/58768/ Peak-to-peak tracking method for measurement of optical path difference: Revisited Ley, H. H. Yahaya, A. Munajat, Y. QC Physics This paper reports on the measurement of optical path difference of spectral interference signal by using the peak-to-peak tracking method in the wavelength domain. Numerical simulations are performed to produce the interference spectrum based on an all fibre Mach-Zehnder interferometer with a white light source. The peak-to-peak tracking method is improvised by measuring the wavelength value corresponding to bright fringes from the phase plot for determination of the optical path difference. The results are compared to the conventional peak-to-peak tracking method and measurement of the slope of phase against wavenumber plot. Optical path difference determined from the improvised method yields higher accuracy with lower uncertainty. Elsevier GmbH 2015 Article PeerReviewed Ley, H. H. and Yahaya, A. and Munajat, Y. (2015) Peak-to-peak tracking method for measurement of optical path difference: Revisited. Optik, 126 (24). pp. 5420-5422. ISSN 3040-26 http://www.dx.doi.org/10.1016/j.ijleo.2015.09.070 DOI: 10.1016/j.ijleo.2015.09.070
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QC Physics
spellingShingle QC Physics
Ley, H. H.
Yahaya, A.
Munajat, Y.
Peak-to-peak tracking method for measurement of optical path difference: Revisited
description This paper reports on the measurement of optical path difference of spectral interference signal by using the peak-to-peak tracking method in the wavelength domain. Numerical simulations are performed to produce the interference spectrum based on an all fibre Mach-Zehnder interferometer with a white light source. The peak-to-peak tracking method is improvised by measuring the wavelength value corresponding to bright fringes from the phase plot for determination of the optical path difference. The results are compared to the conventional peak-to-peak tracking method and measurement of the slope of phase against wavenumber plot. Optical path difference determined from the improvised method yields higher accuracy with lower uncertainty.
format Article
author Ley, H. H.
Yahaya, A.
Munajat, Y.
author_facet Ley, H. H.
Yahaya, A.
Munajat, Y.
author_sort Ley, H. H.
title Peak-to-peak tracking method for measurement of optical path difference: Revisited
title_short Peak-to-peak tracking method for measurement of optical path difference: Revisited
title_full Peak-to-peak tracking method for measurement of optical path difference: Revisited
title_fullStr Peak-to-peak tracking method for measurement of optical path difference: Revisited
title_full_unstemmed Peak-to-peak tracking method for measurement of optical path difference: Revisited
title_sort peak-to-peak tracking method for measurement of optical path difference: revisited
publisher Elsevier GmbH
publishDate 2015
url http://eprints.utm.my/id/eprint/58768/
http://www.dx.doi.org/10.1016/j.ijleo.2015.09.070
_version_ 1712285043042287616