This paper presents the pullout performance of grouted splice connections made with steel pipes and double spirals in connecting high tensile steel deformed bars. The parameters studied were the steel bar embedded lengths, grout strength and diameter of the pipe in influencing the tensile performanc...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2015
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/60801/ http://www.academic.net/show-10-142-1.html |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Summary: | This paper presents the pullout performance of grouted splice connections made with steel pipes and double spirals in connecting high tensile steel deformed bars. The parameters studied were the steel bar embedded lengths, grout strength and diameter of the pipe in influencing the tensile performance of the splice connections. A total of nine proposed grouted spiral connections with double spirals were tested under increasing axial tension until failure. The results indicated that the use of double spiral combined with grout strength of at least 60 N/mm2 and main steel bar embedded length of 10 times bar diameter could provide adequate bond strength to form a satisfactory precast connection system. |
---|