Study of wear prediction on total ankle replacement

Pre-clinical experimental wear testing is very effective to evaluate new ankle replacement in the aspect of design and material used. However, both cost and time can be one of the constraints factors, particularly in the early stage of design or analysis. Numerical method has been addressed as an al...

Full description

Saved in:
Bibliographic Details
Main Authors: Md. Saad, Amir Putra, Harun, Muhamad Noor, Syahrom, Ardiyansyah
Format: Article
Published: Trans Tech 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/62715/
http://dx.doi.org/10.4028/www.scientific.net/AMR.845.311
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.62715
record_format eprints
spelling my.utm.627152017-06-05T02:27:27Z http://eprints.utm.my/id/eprint/62715/ Study of wear prediction on total ankle replacement Md. Saad, Amir Putra Harun, Muhamad Noor Syahrom, Ardiyansyah TJ Mechanical engineering and machinery Pre-clinical experimental wear testing is very effective to evaluate new ankle replacement in the aspect of design and material used. However, both cost and time can be one of the constraints factors, particularly in the early stage of design or analysis. Numerical method has been addressed as an alternative to predict wear on ankle replacement. The computational wear simulation has been widely used on the hip and knee but very less found in study related to wear analysis of the ankle. The purpose of this research is to develop computational simulation to predict wear on total ankle replacement (TAR). Three dimensional (3D) models of the right ankle TAR were developed using BOX total ankle replacement model. Mobile bearing device was developed consisting of three components tibial, bearing and talar. Each component has different design and purposes representing its physiological behaviour of the ankle. The ankle load applied was based on the joint reaction force profile at the ankle joint. This is to determine the distribution of contact stress on the meniscal bearing surfaces contact with talar component for 25 discrete instant during stance phase of gait cycle. The sliding distance was obtained from predominates motion of plantar/dorsi flexion. The computed linear wear depth and cumulative volumetric wear were 0.01614 mm per million cycles and 30.5 mm3, respectively. The values obtained were proven to be consistent with the previous in vitro result. Trans Tech 2014 Article PeerReviewed Md. Saad, Amir Putra and Harun, Muhamad Noor and Syahrom, Ardiyansyah (2014) Study of wear prediction on total ankle replacement. Advanced Materials Research, 845 . pp. 311-315. ISSN 1022-6680 http://dx.doi.org/10.4028/www.scientific.net/AMR.845.311 DOI:10.4028/www.scientific.net/AMR.845.311
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Md. Saad, Amir Putra
Harun, Muhamad Noor
Syahrom, Ardiyansyah
Study of wear prediction on total ankle replacement
description Pre-clinical experimental wear testing is very effective to evaluate new ankle replacement in the aspect of design and material used. However, both cost and time can be one of the constraints factors, particularly in the early stage of design or analysis. Numerical method has been addressed as an alternative to predict wear on ankle replacement. The computational wear simulation has been widely used on the hip and knee but very less found in study related to wear analysis of the ankle. The purpose of this research is to develop computational simulation to predict wear on total ankle replacement (TAR). Three dimensional (3D) models of the right ankle TAR were developed using BOX total ankle replacement model. Mobile bearing device was developed consisting of three components tibial, bearing and talar. Each component has different design and purposes representing its physiological behaviour of the ankle. The ankle load applied was based on the joint reaction force profile at the ankle joint. This is to determine the distribution of contact stress on the meniscal bearing surfaces contact with talar component for 25 discrete instant during stance phase of gait cycle. The sliding distance was obtained from predominates motion of plantar/dorsi flexion. The computed linear wear depth and cumulative volumetric wear were 0.01614 mm per million cycles and 30.5 mm3, respectively. The values obtained were proven to be consistent with the previous in vitro result.
format Article
author Md. Saad, Amir Putra
Harun, Muhamad Noor
Syahrom, Ardiyansyah
author_facet Md. Saad, Amir Putra
Harun, Muhamad Noor
Syahrom, Ardiyansyah
author_sort Md. Saad, Amir Putra
title Study of wear prediction on total ankle replacement
title_short Study of wear prediction on total ankle replacement
title_full Study of wear prediction on total ankle replacement
title_fullStr Study of wear prediction on total ankle replacement
title_full_unstemmed Study of wear prediction on total ankle replacement
title_sort study of wear prediction on total ankle replacement
publisher Trans Tech
publishDate 2014
url http://eprints.utm.my/id/eprint/62715/
http://dx.doi.org/10.4028/www.scientific.net/AMR.845.311
_version_ 1643655501647446016