Total site heat integration incorporating the water sensible heat

Analysis of steam and water losses in the Total Site (TS) utility system is critical in process industry. Makeup water plays an important role in maintaining the water balance in the steam and condensate systems. Total Site Heat Integration (TSHI) offers a solution to increase energy savings as well...

Full description

Saved in:
Bibliographic Details
Main Authors: Liew, Peng Yen, Wan Alwi, Sharifah Rafidah, Lim, Jeng Shiun, Varbanov, Petar Sabev
Format: Article
Published: Elsevier 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/63101/
http://dx.doi.org/10.1016/j.jclepro.2013.12.047
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.63101
record_format eprints
spelling my.utm.631012017-06-14T03:20:27Z http://eprints.utm.my/id/eprint/63101/ Total site heat integration incorporating the water sensible heat Liew, Peng Yen Wan Alwi, Sharifah Rafidah Lim, Jeng Shiun Varbanov, Petar Sabev TP Chemical technology Analysis of steam and water losses in the Total Site (TS) utility system is critical in process industry. Makeup water plays an important role in maintaining the water balance in the steam and condensate systems. Total Site Heat Integration (TSHI) offers a solution to increase energy savings as well as energy efficiency and consequently, to promote sustainability. However, so far most studies on TSHI have not considered the water sensible heat in TS targeting; e.g. for Boiler Feed Water (BFW) preheating and steam superheating during steam generation. In this work, an extended methodology is developed to target the minimum utility requirements in a steam system that considers the water sensible heat. The Extended Total Site Problem Table Algorithm (TS-PTA) is proposed as a systematic numerical tool to consider the sensible heat while targeting the Total Site utility requirements. The Extended Site Composite Curves (ESCC) are developed as a visualisation tool for the Extended TS-PTA. Illustrative and industrial case studies are used to verify the methodology. The results demonstrate the significance of considering the sensible heat of water on the TS utility targets. Elsevier 2014 Article PeerReviewed Liew, Peng Yen and Wan Alwi, Sharifah Rafidah and Lim, Jeng Shiun and Varbanov, Petar Sabev (2014) Total site heat integration incorporating the water sensible heat. Journal of Cleaner Production, 77 . pp. 94-104. ISSN 0959-6526 http://dx.doi.org/10.1016/j.jclepro.2013.12.047 DOI:10.1016/j.jclepro.2013.12.047
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Liew, Peng Yen
Wan Alwi, Sharifah Rafidah
Lim, Jeng Shiun
Varbanov, Petar Sabev
Total site heat integration incorporating the water sensible heat
description Analysis of steam and water losses in the Total Site (TS) utility system is critical in process industry. Makeup water plays an important role in maintaining the water balance in the steam and condensate systems. Total Site Heat Integration (TSHI) offers a solution to increase energy savings as well as energy efficiency and consequently, to promote sustainability. However, so far most studies on TSHI have not considered the water sensible heat in TS targeting; e.g. for Boiler Feed Water (BFW) preheating and steam superheating during steam generation. In this work, an extended methodology is developed to target the minimum utility requirements in a steam system that considers the water sensible heat. The Extended Total Site Problem Table Algorithm (TS-PTA) is proposed as a systematic numerical tool to consider the sensible heat while targeting the Total Site utility requirements. The Extended Site Composite Curves (ESCC) are developed as a visualisation tool for the Extended TS-PTA. Illustrative and industrial case studies are used to verify the methodology. The results demonstrate the significance of considering the sensible heat of water on the TS utility targets.
format Article
author Liew, Peng Yen
Wan Alwi, Sharifah Rafidah
Lim, Jeng Shiun
Varbanov, Petar Sabev
author_facet Liew, Peng Yen
Wan Alwi, Sharifah Rafidah
Lim, Jeng Shiun
Varbanov, Petar Sabev
author_sort Liew, Peng Yen
title Total site heat integration incorporating the water sensible heat
title_short Total site heat integration incorporating the water sensible heat
title_full Total site heat integration incorporating the water sensible heat
title_fullStr Total site heat integration incorporating the water sensible heat
title_full_unstemmed Total site heat integration incorporating the water sensible heat
title_sort total site heat integration incorporating the water sensible heat
publisher Elsevier
publishDate 2014
url http://eprints.utm.my/id/eprint/63101/
http://dx.doi.org/10.1016/j.jclepro.2013.12.047
_version_ 1643655619167649792