Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy

The long presence of metal implants such as titanium alloys in physiological environment will cause an expanded danger of local inflammation and the release of toxic metal ions into human body. So recently, absorbable biocompatible materials attract more attentions. Biodegradable Magnesium alloys du...

Full description

Saved in:
Bibliographic Details
Main Authors: Tafti, Atefeh Ayatollahi, Idris, Jamaliah
Format: Conference or Workshop Item
Published: INSTITUTE OF RESEARCH ENGINEERS AND DOCTORS 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/66649/
https://conferencealerts.com/show-event?id=164485
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.66649
record_format eprints
spelling my.utm.666492017-11-22T00:45:06Z http://eprints.utm.my/id/eprint/66649/ Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy Tafti, Atefeh Ayatollahi Idris, Jamaliah TJ Mechanical engineering and machinery The long presence of metal implants such as titanium alloys in physiological environment will cause an expanded danger of local inflammation and the release of toxic metal ions into human body. So recently, absorbable biocompatible materials attract more attentions. Biodegradable Magnesium alloys due to their excellent load - bearing properties and good biocompatibility became promising candidates to replace common metallic in temporary implants . However, because of unacceptably high degradation rate of Mg in a high chloride environment of the physiological systems a controllable absorbable rate is needed. One of the simplest ways to enhance the corrosion resistance of magnesium alloys is to apply a protective coating on the substrate by using a variety of methods . In this manner, late studies have concentrated on bioactive ceramic coatings, such as calcium phosphate coatings, which displayed great corrosion resistance and exceptional biocompatibility and bioactivity. It was proven that the microwave assisted coating can provide significant improvement in the corrosion resistance of magnesium alloy substrate. Also the irradiation time was important by its effect on crystallization and coating thickness. INSTITUTE OF RESEARCH ENGINEERS AND DOCTORS 2016-01-03 Conference or Workshop Item PeerReviewed Tafti, Atefeh Ayatollahi and Idris, Jamaliah (2016) Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy. In: Fourth International Conference on Advances in Civil, Structural and Mechanical Engineering - CSM, 2016, United Kingdom. https://conferencealerts.com/show-event?id=164485
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Tafti, Atefeh Ayatollahi
Idris, Jamaliah
Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy
description The long presence of metal implants such as titanium alloys in physiological environment will cause an expanded danger of local inflammation and the release of toxic metal ions into human body. So recently, absorbable biocompatible materials attract more attentions. Biodegradable Magnesium alloys due to their excellent load - bearing properties and good biocompatibility became promising candidates to replace common metallic in temporary implants . However, because of unacceptably high degradation rate of Mg in a high chloride environment of the physiological systems a controllable absorbable rate is needed. One of the simplest ways to enhance the corrosion resistance of magnesium alloys is to apply a protective coating on the substrate by using a variety of methods . In this manner, late studies have concentrated on bioactive ceramic coatings, such as calcium phosphate coatings, which displayed great corrosion resistance and exceptional biocompatibility and bioactivity. It was proven that the microwave assisted coating can provide significant improvement in the corrosion resistance of magnesium alloy substrate. Also the irradiation time was important by its effect on crystallization and coating thickness.
format Conference or Workshop Item
author Tafti, Atefeh Ayatollahi
Idris, Jamaliah
author_facet Tafti, Atefeh Ayatollahi
Idris, Jamaliah
author_sort Tafti, Atefeh Ayatollahi
title Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy
title_short Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy
title_full Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy
title_fullStr Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy
title_full_unstemmed Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy
title_sort microwave assisted hydroxyapatite deposition coating on az31 magnesium alloy
publisher INSTITUTE OF RESEARCH ENGINEERS AND DOCTORS
publishDate 2016
url http://eprints.utm.my/id/eprint/66649/
https://conferencealerts.com/show-event?id=164485
_version_ 1643655827556401152