Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy
The long presence of metal implants such as titanium alloys in physiological environment will cause an expanded danger of local inflammation and the release of toxic metal ions into human body. So recently, absorbable biocompatible materials attract more attentions. Biodegradable Magnesium alloys du...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Published: |
INSTITUTE OF RESEARCH ENGINEERS AND DOCTORS
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/66649/ https://conferencealerts.com/show-event?id=164485 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.66649 |
---|---|
record_format |
eprints |
spelling |
my.utm.666492017-11-22T00:45:06Z http://eprints.utm.my/id/eprint/66649/ Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy Tafti, Atefeh Ayatollahi Idris, Jamaliah TJ Mechanical engineering and machinery The long presence of metal implants such as titanium alloys in physiological environment will cause an expanded danger of local inflammation and the release of toxic metal ions into human body. So recently, absorbable biocompatible materials attract more attentions. Biodegradable Magnesium alloys due to their excellent load - bearing properties and good biocompatibility became promising candidates to replace common metallic in temporary implants . However, because of unacceptably high degradation rate of Mg in a high chloride environment of the physiological systems a controllable absorbable rate is needed. One of the simplest ways to enhance the corrosion resistance of magnesium alloys is to apply a protective coating on the substrate by using a variety of methods . In this manner, late studies have concentrated on bioactive ceramic coatings, such as calcium phosphate coatings, which displayed great corrosion resistance and exceptional biocompatibility and bioactivity. It was proven that the microwave assisted coating can provide significant improvement in the corrosion resistance of magnesium alloy substrate. Also the irradiation time was important by its effect on crystallization and coating thickness. INSTITUTE OF RESEARCH ENGINEERS AND DOCTORS 2016-01-03 Conference or Workshop Item PeerReviewed Tafti, Atefeh Ayatollahi and Idris, Jamaliah (2016) Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy. In: Fourth International Conference on Advances in Civil, Structural and Mechanical Engineering - CSM, 2016, United Kingdom. https://conferencealerts.com/show-event?id=164485 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TJ Mechanical engineering and machinery |
spellingShingle |
TJ Mechanical engineering and machinery Tafti, Atefeh Ayatollahi Idris, Jamaliah Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy |
description |
The long presence of metal implants such as titanium alloys in physiological environment will cause an expanded danger of local inflammation and the release of toxic metal ions into human body. So recently, absorbable biocompatible materials attract more attentions. Biodegradable Magnesium alloys due to their excellent load - bearing properties and good biocompatibility became promising candidates to replace common metallic in temporary implants . However, because of unacceptably high degradation rate of Mg in a high chloride environment of the physiological systems a controllable absorbable rate is needed. One of the simplest ways to enhance the corrosion resistance of magnesium alloys is to apply a protective coating on the substrate by using a variety of methods . In this manner, late studies have concentrated on bioactive ceramic coatings, such as calcium phosphate coatings, which displayed great corrosion resistance and exceptional biocompatibility and bioactivity. It was proven that the microwave assisted coating can provide significant improvement in the corrosion resistance of magnesium alloy substrate. Also the irradiation time was important by its effect on crystallization and coating thickness. |
format |
Conference or Workshop Item |
author |
Tafti, Atefeh Ayatollahi Idris, Jamaliah |
author_facet |
Tafti, Atefeh Ayatollahi Idris, Jamaliah |
author_sort |
Tafti, Atefeh Ayatollahi |
title |
Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy |
title_short |
Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy |
title_full |
Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy |
title_fullStr |
Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy |
title_full_unstemmed |
Microwave assisted hydroxyapatite deposition coating on AZ31 magnesium alloy |
title_sort |
microwave assisted hydroxyapatite deposition coating on az31 magnesium alloy |
publisher |
INSTITUTE OF RESEARCH ENGINEERS AND DOCTORS |
publishDate |
2016 |
url |
http://eprints.utm.my/id/eprint/66649/ https://conferencealerts.com/show-event?id=164485 |
_version_ |
1643655827556401152 |