Degradation assessment of nuclear power plant extraction steam piping after long term service
Degradation due to ageing in a Nuclear Power Plant’s Extraction Steam Piping has been assessed. Samples of twelve years old seamless carbon steel SA 106B pipe have been taken and subjected to metallographic examination, hardness testing, radiographic examination and ultrasonic thickness measurement...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/69135/1/M.A.Khattak2016_Degradationassessmentofnuclearpower.pdf http://eprints.utm.my/id/eprint/69135/ http://dx.doi.org/10.11113/jt.v78.7652 |