Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature

Throughout this work the thermal behavior of an adsorptive natural gas (ANG) storage under dynamic discharge conditions at room temperature of 27 C was studied. The work was conducted in a gravimetrically built experimental unit where the storage chamber was equipped with axial and radial distribute...

Full description

Saved in:
Bibliographic Details
Main Authors: Ridha, Firas Noori, M. Yunus, Rosli, Rashid, Mohd., Ismail, Ahmad Fauzi
Format: Article
Published: Elsevier Ltd 2007
Subjects:
Online Access:http://eprints.utm.my/id/eprint/7196/
http://doi.dx.org/10.1016/j.applthermaleng.2006.05.017
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.7196
record_format eprints
spelling my.utm.71962017-10-22T08:36:08Z http://eprints.utm.my/id/eprint/7196/ Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature Ridha, Firas Noori M. Yunus, Rosli Rashid, Mohd. Ismail, Ahmad Fauzi TP Chemical technology Throughout this work the thermal behavior of an adsorptive natural gas (ANG) storage under dynamic discharge conditions at room temperature of 27 C was studied. The work was conducted in a gravimetrically built experimental unit where the storage chamber was equipped with axial and radial distributed thermocouples and the storage was discharged at different discharge rates. The results demonstrated that maximum methane discharge rate of 5 L min1 in activated carbon/methane system resulted in the severest temperature drop corresponding to further drop of about 40% compared to that at 1 L min-1. This extreme thermal condition claimed a reduction of 15.2% in methane dynamic delivery capacity with respect to the isothermal delivery capacity. Ethane and propane have high enthalpies of desorption, and hence high portions of these gases may influence the performance of ANG storages through their thermal impact. A gas mixture with 14.98% and 14.54% volumes of ethane and propane resulted in higher temperature drop than methane claiming a reduction of 19.4% in the dynamic delivery capacity comparing with methane delivery capacity Elsevier Ltd 2007 Article PeerReviewed Ridha, Firas Noori and M. Yunus, Rosli and Rashid, Mohd. and Ismail, Ahmad Fauzi (2007) Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature. Applied Thermal Engineering, 27 (1). pp. 55-62. ISSN 1359-4311 http://doi.dx.org/10.1016/j.applthermaleng.2006.05.017 10.1016/j.applthermaleng.2006.05.017
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Ridha, Firas Noori
M. Yunus, Rosli
Rashid, Mohd.
Ismail, Ahmad Fauzi
Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature
description Throughout this work the thermal behavior of an adsorptive natural gas (ANG) storage under dynamic discharge conditions at room temperature of 27 C was studied. The work was conducted in a gravimetrically built experimental unit where the storage chamber was equipped with axial and radial distributed thermocouples and the storage was discharged at different discharge rates. The results demonstrated that maximum methane discharge rate of 5 L min1 in activated carbon/methane system resulted in the severest temperature drop corresponding to further drop of about 40% compared to that at 1 L min-1. This extreme thermal condition claimed a reduction of 15.2% in methane dynamic delivery capacity with respect to the isothermal delivery capacity. Ethane and propane have high enthalpies of desorption, and hence high portions of these gases may influence the performance of ANG storages through their thermal impact. A gas mixture with 14.98% and 14.54% volumes of ethane and propane resulted in higher temperature drop than methane claiming a reduction of 19.4% in the dynamic delivery capacity comparing with methane delivery capacity
format Article
author Ridha, Firas Noori
M. Yunus, Rosli
Rashid, Mohd.
Ismail, Ahmad Fauzi
author_facet Ridha, Firas Noori
M. Yunus, Rosli
Rashid, Mohd.
Ismail, Ahmad Fauzi
author_sort Ridha, Firas Noori
title Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature
title_short Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature
title_full Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature
title_fullStr Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature
title_full_unstemmed Thermal transient behavior of an ANG storage during dynamic discharge phase at room temperature
title_sort thermal transient behavior of an ang storage during dynamic discharge phase at room temperature
publisher Elsevier Ltd
publishDate 2007
url http://eprints.utm.my/id/eprint/7196/
http://doi.dx.org/10.1016/j.applthermaleng.2006.05.017
_version_ 1643644721481908224