Assessment of harmonic penetration with embedded PV in Nigerian power system
Assessment of the depth of harmonic power penetration in the Nigerian power system with embedded PV is presented. The paper focuses on the investigation of harmonic voltage and current distortions that could be initiated in the Nigerian power system with distributed PV embedded generations. The harm...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2016
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/73281/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84973904791&doi=10.1109%2fPSC.2016.7462819&partnerID=40&md5=249fb76e0f94b3e7ace5df9f8f5c36f4 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.73281 |
---|---|
record_format |
eprints |
spelling |
my.utm.732812017-11-22T12:07:32Z http://eprints.utm.my/id/eprint/73281/ Assessment of harmonic penetration with embedded PV in Nigerian power system Amoo, A. L. Aliyu, U. O. Bakare, G. A. Dalila, M. S. TK Electrical engineering. Electronics Nuclear engineering Assessment of the depth of harmonic power penetration in the Nigerian power system with embedded PV is presented. The paper focuses on the investigation of harmonic voltage and current distortions that could be initiated in the Nigerian power system with distributed PV embedded generations. The harmonic power flow and frequency scan were executed on the network at buses of interest. A twenty-four (24) bus of the existing Nigerian grid has been interconnected with five radial feeders each separately terminated with PV generation. The impedance scan results revealed the level of vulnerability of the network to harmonic distortions with volt and current THDs obtained as 12.98% and 58.5% respectively. Finally, a 200kW embedded PV Grid connected system was implemented in MATLAB/SimPower environment to study the impact of the series reactor harmonic mitigating technique on available power transferred from the PV and was found to reduce by 5%. Institute of Electrical and Electronics Engineers Inc. 2016 Conference or Workshop Item PeerReviewed Amoo, A. L. and Aliyu, U. O. and Bakare, G. A. and Dalila, M. S. (2016) Assessment of harmonic penetration with embedded PV in Nigerian power system. In: Clemson University Power Systems Conference, PSC 2016, 8 March 2016 through 11 March 2016, United States. https://www.scopus.com/inward/record.uri?eid=2-s2.0-84973904791&doi=10.1109%2fPSC.2016.7462819&partnerID=40&md5=249fb76e0f94b3e7ace5df9f8f5c36f4 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Amoo, A. L. Aliyu, U. O. Bakare, G. A. Dalila, M. S. Assessment of harmonic penetration with embedded PV in Nigerian power system |
description |
Assessment of the depth of harmonic power penetration in the Nigerian power system with embedded PV is presented. The paper focuses on the investigation of harmonic voltage and current distortions that could be initiated in the Nigerian power system with distributed PV embedded generations. The harmonic power flow and frequency scan were executed on the network at buses of interest. A twenty-four (24) bus of the existing Nigerian grid has been interconnected with five radial feeders each separately terminated with PV generation. The impedance scan results revealed the level of vulnerability of the network to harmonic distortions with volt and current THDs obtained as 12.98% and 58.5% respectively. Finally, a 200kW embedded PV Grid connected system was implemented in MATLAB/SimPower environment to study the impact of the series reactor harmonic mitigating technique on available power transferred from the PV and was found to reduce by 5%. |
format |
Conference or Workshop Item |
author |
Amoo, A. L. Aliyu, U. O. Bakare, G. A. Dalila, M. S. |
author_facet |
Amoo, A. L. Aliyu, U. O. Bakare, G. A. Dalila, M. S. |
author_sort |
Amoo, A. L. |
title |
Assessment of harmonic penetration with embedded PV in Nigerian power system |
title_short |
Assessment of harmonic penetration with embedded PV in Nigerian power system |
title_full |
Assessment of harmonic penetration with embedded PV in Nigerian power system |
title_fullStr |
Assessment of harmonic penetration with embedded PV in Nigerian power system |
title_full_unstemmed |
Assessment of harmonic penetration with embedded PV in Nigerian power system |
title_sort |
assessment of harmonic penetration with embedded pv in nigerian power system |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2016 |
url |
http://eprints.utm.my/id/eprint/73281/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-84973904791&doi=10.1109%2fPSC.2016.7462819&partnerID=40&md5=249fb76e0f94b3e7ace5df9f8f5c36f4 |
_version_ |
1643656624525541376 |