Radiation doses from computed tomography practice in Johor Bahru, Malaysia

Radiation doses for Computed Tomography (CT) procedures have been reported, encompassing a total of 376 CT examinations conducted in one oncology centre (Hospital Sultan Ismail) and three diagnostic imaging departments (Hospital Sultanah Aminah, Hospital Permai and Hospital Sultan Ismail) at Johor h...

Full description

Saved in:
Bibliographic Details
Main Authors: Karim, M. K. A., Hashim, S., Bradley, D. A., Bakar, K. A., Haron, M. R., Kayun, Z.
Format: Article
Published: Elsevier Ltd 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/73707/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84951750989&doi=10.1016%2fj.radphyschem.2015.12.020&partnerID=40&md5=78f1a8e99eacb1e92855dad03cbb810f
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.73707
record_format eprints
spelling my.utm.737072017-11-18T00:43:57Z http://eprints.utm.my/id/eprint/73707/ Radiation doses from computed tomography practice in Johor Bahru, Malaysia Karim, M. K. A. Hashim, S. Bradley, D. A. Bakar, K. A. Haron, M. R. Kayun, Z. QC Physics Radiation doses for Computed Tomography (CT) procedures have been reported, encompassing a total of 376 CT examinations conducted in one oncology centre (Hospital Sultan Ismail) and three diagnostic imaging departments (Hospital Sultanah Aminah, Hospital Permai and Hospital Sultan Ismail) at Johor hospital's. In each case, dose evaluations were supported by data from patient questionnaires. Each CT examination and radiation doses were verified using the CT EXPO (Ver. 2.3.1, Germany) simulation software. Results are presented in terms of the weighted computed tomography dose index (CTDIw), dose length product (DLP) and effective dose (E). The mean values of CTDIw, DLP and E were ranged between 7.6±0.1 to 64.8±16.5mGy, 170.2±79.2 to 943.3±202.3mGycm and 1.6±0.7 to 11.2±6.5 mSv, respectively. Optimization techniques in CT are suggested to remain necessary, with well-trained radiology personnel remaining at the forefront of such efforts. Elsevier Ltd 2016 Article PeerReviewed Karim, M. K. A. and Hashim, S. and Bradley, D. A. and Bakar, K. A. and Haron, M. R. and Kayun, Z. (2016) Radiation doses from computed tomography practice in Johor Bahru, Malaysia. Radiation Physics and Chemistry, 121 . pp. 69-74. ISSN 0969-806X https://www.scopus.com/inward/record.uri?eid=2-s2.0-84951750989&doi=10.1016%2fj.radphyschem.2015.12.020&partnerID=40&md5=78f1a8e99eacb1e92855dad03cbb810f
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QC Physics
spellingShingle QC Physics
Karim, M. K. A.
Hashim, S.
Bradley, D. A.
Bakar, K. A.
Haron, M. R.
Kayun, Z.
Radiation doses from computed tomography practice in Johor Bahru, Malaysia
description Radiation doses for Computed Tomography (CT) procedures have been reported, encompassing a total of 376 CT examinations conducted in one oncology centre (Hospital Sultan Ismail) and three diagnostic imaging departments (Hospital Sultanah Aminah, Hospital Permai and Hospital Sultan Ismail) at Johor hospital's. In each case, dose evaluations were supported by data from patient questionnaires. Each CT examination and radiation doses were verified using the CT EXPO (Ver. 2.3.1, Germany) simulation software. Results are presented in terms of the weighted computed tomography dose index (CTDIw), dose length product (DLP) and effective dose (E). The mean values of CTDIw, DLP and E were ranged between 7.6±0.1 to 64.8±16.5mGy, 170.2±79.2 to 943.3±202.3mGycm and 1.6±0.7 to 11.2±6.5 mSv, respectively. Optimization techniques in CT are suggested to remain necessary, with well-trained radiology personnel remaining at the forefront of such efforts.
format Article
author Karim, M. K. A.
Hashim, S.
Bradley, D. A.
Bakar, K. A.
Haron, M. R.
Kayun, Z.
author_facet Karim, M. K. A.
Hashim, S.
Bradley, D. A.
Bakar, K. A.
Haron, M. R.
Kayun, Z.
author_sort Karim, M. K. A.
title Radiation doses from computed tomography practice in Johor Bahru, Malaysia
title_short Radiation doses from computed tomography practice in Johor Bahru, Malaysia
title_full Radiation doses from computed tomography practice in Johor Bahru, Malaysia
title_fullStr Radiation doses from computed tomography practice in Johor Bahru, Malaysia
title_full_unstemmed Radiation doses from computed tomography practice in Johor Bahru, Malaysia
title_sort radiation doses from computed tomography practice in johor bahru, malaysia
publisher Elsevier Ltd
publishDate 2016
url http://eprints.utm.my/id/eprint/73707/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84951750989&doi=10.1016%2fj.radphyschem.2015.12.020&partnerID=40&md5=78f1a8e99eacb1e92855dad03cbb810f
_version_ 1643656725520187392