Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance
Researches on separation of multi-particles utilizing microfluidic have been flourishing in recent years with the aid from advancements in microfabrication design and technology. Generally, separation is beneficial for biomedical application especially involving heterogeneous samples. Due to inheren...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/74897/1/MohdRidzuanAhmad_TaperedMicrochannelforMultiParticles.pdf http://eprints.utm.my/id/eprint/74897/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016990298&doi=10.11591%2fijeecs.v5.i3.pp628-635&partnerID=40&md5=0802d2245e433148aa6b9c27d4cbebdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.74897 |
---|---|
record_format |
eprints |
spelling |
my.utm.748972018-03-22T10:55:57Z http://eprints.utm.my/id/eprint/74897/ Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance Ahmad, I. L. Ahmad, M. R. TK Electrical engineering. Electronics Nuclear engineering Researches on separation of multi-particles utilizing microfluidic have been flourishing in recent years with the aid from advancements in microfabrication design and technology. Generally, separation is beneficial for biomedical application especially involving heterogeneous samples. Due to inherent problems of samples isolation, a simple and efficient separation device is required. Here, we present a passive tapered microchannel for multi-particles separation using hydrodynamic principle. Our emphasis is on the effect of hydrodynamic resistance coupled with tapered microchannel design. In the experiment, successful multi-particles samples separation was observed. The results were further analyzed and were in agreement with the proposed concept. This method opens the route toward robust, low-cost and high-throughput, thus it may holds potential to be integrated as one functional module in Micro Total Analysis System (µTAS). Institute of Advanced Engineering and Science 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/74897/1/MohdRidzuanAhmad_TaperedMicrochannelforMultiParticles.pdf Ahmad, I. L. and Ahmad, M. R. (2017) Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance. Indonesian Journal of Electrical Engineering and Computer Science, 5 (3). pp. 628-635. ISSN 2502-4752 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016990298&doi=10.11591%2fijeecs.v5.i3.pp628-635&partnerID=40&md5=0802d2245e433148aa6b9c27d4cbebdf |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Ahmad, I. L. Ahmad, M. R. Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance |
description |
Researches on separation of multi-particles utilizing microfluidic have been flourishing in recent years with the aid from advancements in microfabrication design and technology. Generally, separation is beneficial for biomedical application especially involving heterogeneous samples. Due to inherent problems of samples isolation, a simple and efficient separation device is required. Here, we present a passive tapered microchannel for multi-particles separation using hydrodynamic principle. Our emphasis is on the effect of hydrodynamic resistance coupled with tapered microchannel design. In the experiment, successful multi-particles samples separation was observed. The results were further analyzed and were in agreement with the proposed concept. This method opens the route toward robust, low-cost and high-throughput, thus it may holds potential to be integrated as one functional module in Micro Total Analysis System (µTAS). |
format |
Article |
author |
Ahmad, I. L. Ahmad, M. R. |
author_facet |
Ahmad, I. L. Ahmad, M. R. |
author_sort |
Ahmad, I. L. |
title |
Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance |
title_short |
Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance |
title_full |
Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance |
title_fullStr |
Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance |
title_full_unstemmed |
Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance |
title_sort |
tapered microchannel for multi-particles passive separation based on hydrodynamic resistance |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2017 |
url |
http://eprints.utm.my/id/eprint/74897/1/MohdRidzuanAhmad_TaperedMicrochannelforMultiParticles.pdf http://eprints.utm.my/id/eprint/74897/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016990298&doi=10.11591%2fijeecs.v5.i3.pp628-635&partnerID=40&md5=0802d2245e433148aa6b9c27d4cbebdf |
_version_ |
1643656965089394688 |