Characterization of sensing chamber design for E-nose applications

An electronic nose (e-nose) is a device that mimics the function of the human nose and is able to recognize odours using gas sensors. The e-nose consists of a sampling system, a sensor array (in the detection system), with data acquisition and pattern recognition algorithm for computing system. The...

Full description

Saved in:
Bibliographic Details
Main Authors: Samiyan, N. S., Mohd. Addi, M.
Format: Article
Published: Universiti Teknikal Malaysia Melaka 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/76616/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041922881&partnerID=40&md5=1bcb3ebf6604063dc618e2a195154f3a
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.76616
record_format eprints
spelling my.utm.766162018-04-30T13:44:55Z http://eprints.utm.my/id/eprint/76616/ Characterization of sensing chamber design for E-nose applications Samiyan, N. S. Mohd. Addi, M. TK Electrical engineering. Electronics Nuclear engineering An electronic nose (e-nose) is a device that mimics the function of the human nose and is able to recognize odours using gas sensors. The e-nose consists of a sampling system, a sensor array (in the detection system), with data acquisition and pattern recognition algorithm for computing system. The sensing chamber in an e-nose plays an important role in the detection system for any types of application. The design of the sensing chambers will determine several performance characteristics of the sensor's response signals which include the response time, stagnant region and gas to the sensor contact area. Several sensing chambers (rectangular, hemisphere & cylindrical) were designed using SolidWorks and printed (in 3-dimensional (3D)) to characterize and determine the design which is able to provide the optimum performance. Data analysis of the response time and parameters such as concentration and pressure were analyzed using NI LabView. Results show that the hemisphere shaped sensing chamber displayed the best performance in terms of a small stagnant region and a large gas to the sensor contact area even though the time response between sensing chambers is almost the same. The performance was due to the flow of the gas from the inlet to the outlet and the volume of the sensing chamber. Universiti Teknikal Malaysia Melaka 2017 Article PeerReviewed Samiyan, N. S. and Mohd. Addi, M. (2017) Characterization of sensing chamber design for E-nose applications. Journal of Telecommunication, Electronic and Computer Engineering, 9 (3-9). pp. 123-127. ISSN 2180-1843 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041922881&partnerID=40&md5=1bcb3ebf6604063dc618e2a195154f3a
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Samiyan, N. S.
Mohd. Addi, M.
Characterization of sensing chamber design for E-nose applications
description An electronic nose (e-nose) is a device that mimics the function of the human nose and is able to recognize odours using gas sensors. The e-nose consists of a sampling system, a sensor array (in the detection system), with data acquisition and pattern recognition algorithm for computing system. The sensing chamber in an e-nose plays an important role in the detection system for any types of application. The design of the sensing chambers will determine several performance characteristics of the sensor's response signals which include the response time, stagnant region and gas to the sensor contact area. Several sensing chambers (rectangular, hemisphere & cylindrical) were designed using SolidWorks and printed (in 3-dimensional (3D)) to characterize and determine the design which is able to provide the optimum performance. Data analysis of the response time and parameters such as concentration and pressure were analyzed using NI LabView. Results show that the hemisphere shaped sensing chamber displayed the best performance in terms of a small stagnant region and a large gas to the sensor contact area even though the time response between sensing chambers is almost the same. The performance was due to the flow of the gas from the inlet to the outlet and the volume of the sensing chamber.
format Article
author Samiyan, N. S.
Mohd. Addi, M.
author_facet Samiyan, N. S.
Mohd. Addi, M.
author_sort Samiyan, N. S.
title Characterization of sensing chamber design for E-nose applications
title_short Characterization of sensing chamber design for E-nose applications
title_full Characterization of sensing chamber design for E-nose applications
title_fullStr Characterization of sensing chamber design for E-nose applications
title_full_unstemmed Characterization of sensing chamber design for E-nose applications
title_sort characterization of sensing chamber design for e-nose applications
publisher Universiti Teknikal Malaysia Melaka
publishDate 2017
url http://eprints.utm.my/id/eprint/76616/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85041922881&partnerID=40&md5=1bcb3ebf6604063dc618e2a195154f3a
_version_ 1643657361564368896