Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor

Surface plasmon resonance (SPR)-based biosensing is an accurate and sensitive technique used to evaluate the biomolecular interactions in real time in a label-free environment. Several new approaches have been proposed to improve the sensitivity of SPR sensors. The development of sensing surfaces ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Meshginqalam, B., Ahmadi, M. T., Ismail, R., Sabatyan, A.
Format: Article
Published: Springer New York LLC 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/77041/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85004072314&doi=10.1007%2fs11468-016-0472-2&partnerID=40&md5=3546f05f041ef71105e20acbdb3a11d8
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.77041
record_format eprints
spelling my.utm.770412018-04-30T14:36:32Z http://eprints.utm.my/id/eprint/77041/ Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor Meshginqalam, B. Ahmadi, M. T. Ismail, R. Sabatyan, A. TK Electrical engineering. Electronics Nuclear engineering Surface plasmon resonance (SPR)-based biosensing is an accurate and sensitive technique used to evaluate the biomolecular interactions in real time in a label-free environment. Several new approaches have been proposed to improve the sensitivity of SPR sensors. The development of sensing surfaces can significantly improve the performance of biosensors; graphene and graphene oxide (GO) offer several advantages due to their extraordinary optical and structural properties. In this paper, the SPR biosensor structure based on graphene and GO linking layers are suggested. For proposed configurations, the features and characteristics such as reflectivity and sensitivity using the finite element analysis (FEA) model are discussed and compared with results from N-layer model. The effect of cap layer thickness in the sensitivity of the SPR biosensor has been calculated. Computational results show that the proposed graphene and GO-based SPR biosensor have more than two and four times greater sensitivity than the conventional gold film-based SPR sensor respectively due to their better adsorption of biomolecules. Springer New York LLC 2017 Article PeerReviewed Meshginqalam, B. and Ahmadi, M. T. and Ismail, R. and Sabatyan, A. (2017) Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor. Plasmonics, 12 (6). pp. 1991-1997. ISSN 1557-1955 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85004072314&doi=10.1007%2fs11468-016-0472-2&partnerID=40&md5=3546f05f041ef71105e20acbdb3a11d8 DOI:10.1007/s11468-016-0472-2
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Meshginqalam, B.
Ahmadi, M. T.
Ismail, R.
Sabatyan, A.
Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
description Surface plasmon resonance (SPR)-based biosensing is an accurate and sensitive technique used to evaluate the biomolecular interactions in real time in a label-free environment. Several new approaches have been proposed to improve the sensitivity of SPR sensors. The development of sensing surfaces can significantly improve the performance of biosensors; graphene and graphene oxide (GO) offer several advantages due to their extraordinary optical and structural properties. In this paper, the SPR biosensor structure based on graphene and GO linking layers are suggested. For proposed configurations, the features and characteristics such as reflectivity and sensitivity using the finite element analysis (FEA) model are discussed and compared with results from N-layer model. The effect of cap layer thickness in the sensitivity of the SPR biosensor has been calculated. Computational results show that the proposed graphene and GO-based SPR biosensor have more than two and four times greater sensitivity than the conventional gold film-based SPR sensor respectively due to their better adsorption of biomolecules.
format Article
author Meshginqalam, B.
Ahmadi, M. T.
Ismail, R.
Sabatyan, A.
author_facet Meshginqalam, B.
Ahmadi, M. T.
Ismail, R.
Sabatyan, A.
author_sort Meshginqalam, B.
title Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
title_short Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
title_full Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
title_fullStr Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
title_full_unstemmed Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
title_sort graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
publisher Springer New York LLC
publishDate 2017
url http://eprints.utm.my/id/eprint/77041/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85004072314&doi=10.1007%2fs11468-016-0472-2&partnerID=40&md5=3546f05f041ef71105e20acbdb3a11d8
_version_ 1643657480675262464