Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor
Surface plasmon resonance (SPR)-based biosensing is an accurate and sensitive technique used to evaluate the biomolecular interactions in real time in a label-free environment. Several new approaches have been proposed to improve the sensitivity of SPR sensors. The development of sensing surfaces ca...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Springer New York LLC
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/77041/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85004072314&doi=10.1007%2fs11468-016-0472-2&partnerID=40&md5=3546f05f041ef71105e20acbdb3a11d8 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.77041 |
---|---|
record_format |
eprints |
spelling |
my.utm.770412018-04-30T14:36:32Z http://eprints.utm.my/id/eprint/77041/ Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor Meshginqalam, B. Ahmadi, M. T. Ismail, R. Sabatyan, A. TK Electrical engineering. Electronics Nuclear engineering Surface plasmon resonance (SPR)-based biosensing is an accurate and sensitive technique used to evaluate the biomolecular interactions in real time in a label-free environment. Several new approaches have been proposed to improve the sensitivity of SPR sensors. The development of sensing surfaces can significantly improve the performance of biosensors; graphene and graphene oxide (GO) offer several advantages due to their extraordinary optical and structural properties. In this paper, the SPR biosensor structure based on graphene and GO linking layers are suggested. For proposed configurations, the features and characteristics such as reflectivity and sensitivity using the finite element analysis (FEA) model are discussed and compared with results from N-layer model. The effect of cap layer thickness in the sensitivity of the SPR biosensor has been calculated. Computational results show that the proposed graphene and GO-based SPR biosensor have more than two and four times greater sensitivity than the conventional gold film-based SPR sensor respectively due to their better adsorption of biomolecules. Springer New York LLC 2017 Article PeerReviewed Meshginqalam, B. and Ahmadi, M. T. and Ismail, R. and Sabatyan, A. (2017) Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor. Plasmonics, 12 (6). pp. 1991-1997. ISSN 1557-1955 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85004072314&doi=10.1007%2fs11468-016-0472-2&partnerID=40&md5=3546f05f041ef71105e20acbdb3a11d8 DOI:10.1007/s11468-016-0472-2 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Meshginqalam, B. Ahmadi, M. T. Ismail, R. Sabatyan, A. Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor |
description |
Surface plasmon resonance (SPR)-based biosensing is an accurate and sensitive technique used to evaluate the biomolecular interactions in real time in a label-free environment. Several new approaches have been proposed to improve the sensitivity of SPR sensors. The development of sensing surfaces can significantly improve the performance of biosensors; graphene and graphene oxide (GO) offer several advantages due to their extraordinary optical and structural properties. In this paper, the SPR biosensor structure based on graphene and GO linking layers are suggested. For proposed configurations, the features and characteristics such as reflectivity and sensitivity using the finite element analysis (FEA) model are discussed and compared with results from N-layer model. The effect of cap layer thickness in the sensitivity of the SPR biosensor has been calculated. Computational results show that the proposed graphene and GO-based SPR biosensor have more than two and four times greater sensitivity than the conventional gold film-based SPR sensor respectively due to their better adsorption of biomolecules. |
format |
Article |
author |
Meshginqalam, B. Ahmadi, M. T. Ismail, R. Sabatyan, A. |
author_facet |
Meshginqalam, B. Ahmadi, M. T. Ismail, R. Sabatyan, A. |
author_sort |
Meshginqalam, B. |
title |
Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor |
title_short |
Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor |
title_full |
Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor |
title_fullStr |
Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor |
title_full_unstemmed |
Graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor |
title_sort |
graphene/graphene oxide-based ultrasensitive surface plasmon resonance biosensor |
publisher |
Springer New York LLC |
publishDate |
2017 |
url |
http://eprints.utm.my/id/eprint/77041/ https://www.scopus.com/inward/record.uri?eid=2-s2.0-85004072314&doi=10.1007%2fs11468-016-0472-2&partnerID=40&md5=3546f05f041ef71105e20acbdb3a11d8 |
_version_ |
1643657480675262464 |