Hybrid inertial-manipulator based position tracking system for ultrasound imaging application
In medical field, ultrasound imaging is one of the imaging modalities that needs position tracking system (PTS) in enlarging field of view (FoV) of an image. The enlarged FoV will result easier scanning procedure, and produce more accurate and comprehensive results. To overcome the weakness of comme...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2017
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/78846/1/MuhaiminMohdFadzilMFKE2017.pdf http://eprints.utm.my/id/eprint/78846/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:109578 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.78846 |
---|---|
record_format |
eprints |
spelling |
my.utm.788462018-09-17T04:21:12Z http://eprints.utm.my/id/eprint/78846/ Hybrid inertial-manipulator based position tracking system for ultrasound imaging application Mohd. Fadzil, Muhaimin TK Electrical engineering. Electronics Nuclear engineering In medical field, ultrasound imaging is one of the imaging modalities that needs position tracking system (PTS) in enlarging field of view (FoV) of an image. The enlarged FoV will result easier scanning procedure, and produce more accurate and comprehensive results. To overcome the weakness of commercially available PTSs which suffer from interference and occlusion, many researchers proposed improved PTSs. However, the improved PTSs focused on the portability and compact design, neglecting the vertical scanning aspect which is also important in ultrasound imaging. Hence, this research presents the development of hybrid inertial-manipulator based PTS for 3-dimensional (3D) ultrasound imaging system which capable of measuring the horizontal and vertical scanning movements. The proposed PTS uses the combination of inertial measurement unit sensor and manipulator. The research involves design and evaluation processes for the PTS. Once the design process of the PTS is completed, forward kinematics is calculated using Denavit-Hartenberg conversion. The next step is to evaluate the accuracy and repeatability of the output of the designed PTS by comparing with five sets of reference trajectory of ABB robot. A comparison of the accuracy for the proposed PTS with three other available PTSs is done using the horizontal movement’s error. The experimental results showed high repeatability of position output reading of the designed PTS with standard deviation of 0.27 mm in all different movements and speeds. The proposed PTS is suitable to be used in ultrasound imaging as the error is less than 1.45 mm. Furthermore, the proposed PTS can measure the vertical scanning movement which is neglected in all the previous works, thus fulfilling the main objective of the research. 2017-11 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/78846/1/MuhaiminMohdFadzilMFKE2017.pdf Mohd. Fadzil, Muhaimin (2017) Hybrid inertial-manipulator based position tracking system for ultrasound imaging application. Masters thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:109578 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Mohd. Fadzil, Muhaimin Hybrid inertial-manipulator based position tracking system for ultrasound imaging application |
description |
In medical field, ultrasound imaging is one of the imaging modalities that needs position tracking system (PTS) in enlarging field of view (FoV) of an image. The enlarged FoV will result easier scanning procedure, and produce more accurate and comprehensive results. To overcome the weakness of commercially available PTSs which suffer from interference and occlusion, many researchers proposed improved PTSs. However, the improved PTSs focused on the portability and compact design, neglecting the vertical scanning aspect which is also important in ultrasound imaging. Hence, this research presents the development of hybrid inertial-manipulator based PTS for 3-dimensional (3D) ultrasound imaging system which capable of measuring the horizontal and vertical scanning movements. The proposed PTS uses the combination of inertial measurement unit sensor and manipulator. The research involves design and evaluation processes for the PTS. Once the design process of the PTS is completed, forward kinematics is calculated using Denavit-Hartenberg conversion. The next step is to evaluate the accuracy and repeatability of the output of the designed PTS by comparing with five sets of reference trajectory of ABB robot. A comparison of the accuracy for the proposed PTS with three other available PTSs is done using the horizontal movement’s error. The experimental results showed high repeatability of position output reading of the designed PTS with standard deviation of 0.27 mm in all different movements and speeds. The proposed PTS is suitable to be used in ultrasound imaging as the error is less than 1.45 mm. Furthermore, the proposed PTS can measure the vertical scanning movement which is neglected in all the previous works, thus fulfilling the main objective of the research. |
format |
Thesis |
author |
Mohd. Fadzil, Muhaimin |
author_facet |
Mohd. Fadzil, Muhaimin |
author_sort |
Mohd. Fadzil, Muhaimin |
title |
Hybrid inertial-manipulator based position tracking system for ultrasound imaging application |
title_short |
Hybrid inertial-manipulator based position tracking system for ultrasound imaging application |
title_full |
Hybrid inertial-manipulator based position tracking system for ultrasound imaging application |
title_fullStr |
Hybrid inertial-manipulator based position tracking system for ultrasound imaging application |
title_full_unstemmed |
Hybrid inertial-manipulator based position tracking system for ultrasound imaging application |
title_sort |
hybrid inertial-manipulator based position tracking system for ultrasound imaging application |
publishDate |
2017 |
url |
http://eprints.utm.my/id/eprint/78846/1/MuhaiminMohdFadzilMFKE2017.pdf http://eprints.utm.my/id/eprint/78846/ http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:109578 |
_version_ |
1643658022700974080 |