Investigation of using potentiostats and microfluidic devices for continuous ions detection

In the light of the importance of the bedside patient monitoring system, a miniaturized, flexible, versatile, disposable and cost effective bedside patient continuous monitoring system is essential. Therefore, this research addresses the development of a cost effective and miniaturize continuous mon...

Full description

Saved in:
Bibliographic Details
Main Author: Noi, Sherrin
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79032/1/SherrinNoiMFBME2016.pdf
http://eprints.utm.my/id/eprint/79032/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:110540
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.79032
record_format eprints
spelling my.utm.790322018-09-27T04:15:36Z http://eprints.utm.my/id/eprint/79032/ Investigation of using potentiostats and microfluidic devices for continuous ions detection Noi, Sherrin TP Chemical technology In the light of the importance of the bedside patient monitoring system, a miniaturized, flexible, versatile, disposable and cost effective bedside patient continuous monitoring system is essential. Therefore, this research addresses the development of a cost effective and miniaturize continuous monitoring system. For electrochemical analysis, three potentiostats were used: EmStat, CheapStat and in house UTMStat. For lab-on-chip system, two models were proposed and their electrochemistry and pumping characteristics were studied. The 2 layers detection zone was developed through fused filament technology and replication moulding technique with a screen printed electrode attached together. It achieved the maximum flow rate of 0.30405 ml/min with resonance frequency of 20 Hz in micropump reverse direction. With the maximum frequency, the highest oxidation peak current of 15.86176 |iA in cyclic voltammetry measurement was achieved by 10 mM ferrocyanide ions at potential 0.25 V. The monolithic microfluidic device was developed through sticker masks fabrication and replication moulding technique with two screen printed electrodes attached beneath the inlets and the outlets of the micropump. It achieved the maximum flow rate of 0.19693 ml/min with resonance frequency of 10 Hz in micropump forward direction. With the maximum frequency, the highest oxidation peak current of 28.32518 |xA in cyclic voltammetry measurement was achieved by 10 mM ferrocyanide ions at potential 0.32 V. Additionally, the electrochemical investigation was extended by measuring the cyclic voltammetry measurements of chloride ions from a mixture by using EmStat and CheapStat. The highest oxidation peak was observed at 61.26875 |jA and 1.04400 |±A by using EmStat and CheapStat respectively at potential 0.13 V. Specifically, the monolithic microfluidic device is well integrated in lab-on-chip system with the advantage of miniaturize with the dimensions of 41 mm x 26 mm, cost effective by using sticker masks fabrication and replication moulding technique, disposability since it is inexpensive and meant for biomedical analysis, flexibility where it can be used for other ions detection just by changing the screen printed electrode and can measure the data during pumping. This research successfully provides an alternative approach for continuous monitoring of ferrocyanide and chloride ions detection via cyclic voltammetry and amperometry measurements. 2016-08 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/79032/1/SherrinNoiMFBME2016.pdf Noi, Sherrin (2016) Investigation of using potentiostats and microfluidic devices for continuous ions detection. Masters thesis, Universiti Teknologi Malaysia, Faculty of Biosciences and Medical Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:110540
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Noi, Sherrin
Investigation of using potentiostats and microfluidic devices for continuous ions detection
description In the light of the importance of the bedside patient monitoring system, a miniaturized, flexible, versatile, disposable and cost effective bedside patient continuous monitoring system is essential. Therefore, this research addresses the development of a cost effective and miniaturize continuous monitoring system. For electrochemical analysis, three potentiostats were used: EmStat, CheapStat and in house UTMStat. For lab-on-chip system, two models were proposed and their electrochemistry and pumping characteristics were studied. The 2 layers detection zone was developed through fused filament technology and replication moulding technique with a screen printed electrode attached together. It achieved the maximum flow rate of 0.30405 ml/min with resonance frequency of 20 Hz in micropump reverse direction. With the maximum frequency, the highest oxidation peak current of 15.86176 |iA in cyclic voltammetry measurement was achieved by 10 mM ferrocyanide ions at potential 0.25 V. The monolithic microfluidic device was developed through sticker masks fabrication and replication moulding technique with two screen printed electrodes attached beneath the inlets and the outlets of the micropump. It achieved the maximum flow rate of 0.19693 ml/min with resonance frequency of 10 Hz in micropump forward direction. With the maximum frequency, the highest oxidation peak current of 28.32518 |xA in cyclic voltammetry measurement was achieved by 10 mM ferrocyanide ions at potential 0.32 V. Additionally, the electrochemical investigation was extended by measuring the cyclic voltammetry measurements of chloride ions from a mixture by using EmStat and CheapStat. The highest oxidation peak was observed at 61.26875 |jA and 1.04400 |±A by using EmStat and CheapStat respectively at potential 0.13 V. Specifically, the monolithic microfluidic device is well integrated in lab-on-chip system with the advantage of miniaturize with the dimensions of 41 mm x 26 mm, cost effective by using sticker masks fabrication and replication moulding technique, disposability since it is inexpensive and meant for biomedical analysis, flexibility where it can be used for other ions detection just by changing the screen printed electrode and can measure the data during pumping. This research successfully provides an alternative approach for continuous monitoring of ferrocyanide and chloride ions detection via cyclic voltammetry and amperometry measurements.
format Thesis
author Noi, Sherrin
author_facet Noi, Sherrin
author_sort Noi, Sherrin
title Investigation of using potentiostats and microfluidic devices for continuous ions detection
title_short Investigation of using potentiostats and microfluidic devices for continuous ions detection
title_full Investigation of using potentiostats and microfluidic devices for continuous ions detection
title_fullStr Investigation of using potentiostats and microfluidic devices for continuous ions detection
title_full_unstemmed Investigation of using potentiostats and microfluidic devices for continuous ions detection
title_sort investigation of using potentiostats and microfluidic devices for continuous ions detection
publishDate 2016
url http://eprints.utm.my/id/eprint/79032/1/SherrinNoiMFBME2016.pdf
http://eprints.utm.my/id/eprint/79032/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:110540
_version_ 1643658077839294464