Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru

As the time passes, the design of houses in Malaysia has evolved. Traditional Malay houses that were shaded by trees have turned into modern terraced houses that are compact and exposed to sun heat. Unlike traditional Malay houses, the internal temperature of modern terraced houses is much higher th...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd. Razif, Farhana
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79289/1/FarhanaMohdRazifMFAB2015.pdf
http://eprints.utm.my/id/eprint/79289/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.79289
record_format eprints
spelling my.utm.792892018-10-14T08:42:02Z http://eprints.utm.my/id/eprint/79289/ Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru Mohd. Razif, Farhana HT101-395 Sociology, Urban As the time passes, the design of houses in Malaysia has evolved. Traditional Malay houses that were shaded by trees have turned into modern terraced houses that are compact and exposed to sun heat. Unlike traditional Malay houses, the internal temperature of modern terraced houses is much higher than outside. To reduce the amount of heat transferred from the sun through the roof, the most efficient and costeffective way is by installing roof thermal insulation. This thesis investigated the terraced houses’ resident’s level of knowledge on roof thermal insulation and their willingness to install roof thermal insulation in their houses. By using quantitative method, a questionnaire survey was conducted to 356 Johor Bahru’s residents living in low, medium, and high cost terraced houses that were built in the 1980s, 1990s, and 2000s. The result showed that the respondent’s level of knowledge on types of roof thermal insulation was below the median value of 3. However, the response to the importance of roof thermal insulation was at a good level at which the mode value is 4 out of 5 choices of likert scale. The result also showed that the median value of respondents’ willingness to spend for the installation of roof thermal insulation is RM1000. Although the respondents’ knowledge on types of roof thermal insulation was low, the level of awareness on the importance of roof thermal insulation was high. There are willingness among respondents to invest in order to achieve cooler indoor temperature and lower monthly electricity bill. By promoting the use of thermal insulation on a large scale, the use of thermal insulation among terraced houses residents can be improved. 2015 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/79289/1/FarhanaMohdRazifMFAB2015.pdf Mohd. Razif, Farhana (2015) Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru. Masters thesis, Universiti Teknologi Malaysia, Faculty of Built Environment.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic HT101-395 Sociology, Urban
spellingShingle HT101-395 Sociology, Urban
Mohd. Razif, Farhana
Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru
description As the time passes, the design of houses in Malaysia has evolved. Traditional Malay houses that were shaded by trees have turned into modern terraced houses that are compact and exposed to sun heat. Unlike traditional Malay houses, the internal temperature of modern terraced houses is much higher than outside. To reduce the amount of heat transferred from the sun through the roof, the most efficient and costeffective way is by installing roof thermal insulation. This thesis investigated the terraced houses’ resident’s level of knowledge on roof thermal insulation and their willingness to install roof thermal insulation in their houses. By using quantitative method, a questionnaire survey was conducted to 356 Johor Bahru’s residents living in low, medium, and high cost terraced houses that were built in the 1980s, 1990s, and 2000s. The result showed that the respondent’s level of knowledge on types of roof thermal insulation was below the median value of 3. However, the response to the importance of roof thermal insulation was at a good level at which the mode value is 4 out of 5 choices of likert scale. The result also showed that the median value of respondents’ willingness to spend for the installation of roof thermal insulation is RM1000. Although the respondents’ knowledge on types of roof thermal insulation was low, the level of awareness on the importance of roof thermal insulation was high. There are willingness among respondents to invest in order to achieve cooler indoor temperature and lower monthly electricity bill. By promoting the use of thermal insulation on a large scale, the use of thermal insulation among terraced houses residents can be improved.
format Thesis
author Mohd. Razif, Farhana
author_facet Mohd. Razif, Farhana
author_sort Mohd. Razif, Farhana
title Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru
title_short Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru
title_full Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru
title_fullStr Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru
title_full_unstemmed Tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di Johor Bahru
title_sort tahap penerimaan semasa pengguna terhadap penebat haba bumbung rumah teres di johor bahru
publishDate 2015
url http://eprints.utm.my/id/eprint/79289/1/FarhanaMohdRazifMFAB2015.pdf
http://eprints.utm.my/id/eprint/79289/
_version_ 1643658152367882240