Frequency-controlled wireless passive microfluidic devices

Microfluidics is a promising technology that is increasingly attracting the attention of researchers due to its high efficiency and low-cost features. Micropumps, micromixers, and microvalves have been widely applied in various biomedical applications due to their compact size and precise dosage con...

Full description

Saved in:
Bibliographic Details
Main Author: Minjal, Marwan Nafea
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79363/1/MarwanNafeaMinjalPFKE2018.pdf
http://eprints.utm.my/id/eprint/79363/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.79363
record_format eprints
spelling my.utm.793632018-10-14T08:44:55Z http://eprints.utm.my/id/eprint/79363/ Frequency-controlled wireless passive microfluidic devices Minjal, Marwan Nafea TK Electrical engineering. Electronics Nuclear engineering Microfluidics is a promising technology that is increasingly attracting the attention of researchers due to its high efficiency and low-cost features. Micropumps, micromixers, and microvalves have been widely applied in various biomedical applications due to their compact size and precise dosage controllability. Nevertheless, despite the vast amount of research reported in this research area, the ability to implement these devices in portable and implantable applications is still limited. To date, such devices are constricted to the use of wires, or on-board power supplies, such as batteries. This thesis presents novel techniques that allow wireless control of passive microfluidic devices using an external radiofrequency magnetic field utilizing thermopneumatic principle. Three microfluidic devices are designed and developed to perform within the range of implantable drug-delivery devices. To demonstrate the wireless control of microfluidic devices, a wireless implantable thermopneumatic micropump is presented. Thermopneumatic pumping with a maximum flow rate of 2.86 μL/min is realized using a planar wirelessly-controlled passive inductor-capacitor heater. Then, this principle was extended in order to demonstrate the selective wireless control of multiple passive heaters. A passive wirelessly-controlled thermopneumatic zigzag micromixer is developed as a mean of a multiple drug delivery device. A maximum mixing efficiency of 96.1% is achieved by selectively activating two passive wireless planar inductor-capacitor heaters that have different resonant frequency values. To eliminate the heat associated with aforementioned wireless devices, a wireless piezoelectric normally-closed microvalve for drug delivery applications is developed. A piezoelectric diaphragm is operated wirelessly using the wireless power that is transferred from an external magnetic field. Valving is achieved with a percentage error as low as 3.11% in a 3 days long-term functionality test. The developed devices present a promising implementation of the reported wireless actuation principles in various portable and implantable biomedical applications, such as drug delivery, analytical assays, and cell lysis devices. 2018 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/79363/1/MarwanNafeaMinjalPFKE2018.pdf Minjal, Marwan Nafea (2018) Frequency-controlled wireless passive microfluidic devices. PhD thesis, Universiti Teknologi Malaysia, Faculty of Electrical Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Minjal, Marwan Nafea
Frequency-controlled wireless passive microfluidic devices
description Microfluidics is a promising technology that is increasingly attracting the attention of researchers due to its high efficiency and low-cost features. Micropumps, micromixers, and microvalves have been widely applied in various biomedical applications due to their compact size and precise dosage controllability. Nevertheless, despite the vast amount of research reported in this research area, the ability to implement these devices in portable and implantable applications is still limited. To date, such devices are constricted to the use of wires, or on-board power supplies, such as batteries. This thesis presents novel techniques that allow wireless control of passive microfluidic devices using an external radiofrequency magnetic field utilizing thermopneumatic principle. Three microfluidic devices are designed and developed to perform within the range of implantable drug-delivery devices. To demonstrate the wireless control of microfluidic devices, a wireless implantable thermopneumatic micropump is presented. Thermopneumatic pumping with a maximum flow rate of 2.86 μL/min is realized using a planar wirelessly-controlled passive inductor-capacitor heater. Then, this principle was extended in order to demonstrate the selective wireless control of multiple passive heaters. A passive wirelessly-controlled thermopneumatic zigzag micromixer is developed as a mean of a multiple drug delivery device. A maximum mixing efficiency of 96.1% is achieved by selectively activating two passive wireless planar inductor-capacitor heaters that have different resonant frequency values. To eliminate the heat associated with aforementioned wireless devices, a wireless piezoelectric normally-closed microvalve for drug delivery applications is developed. A piezoelectric diaphragm is operated wirelessly using the wireless power that is transferred from an external magnetic field. Valving is achieved with a percentage error as low as 3.11% in a 3 days long-term functionality test. The developed devices present a promising implementation of the reported wireless actuation principles in various portable and implantable biomedical applications, such as drug delivery, analytical assays, and cell lysis devices.
format Thesis
author Minjal, Marwan Nafea
author_facet Minjal, Marwan Nafea
author_sort Minjal, Marwan Nafea
title Frequency-controlled wireless passive microfluidic devices
title_short Frequency-controlled wireless passive microfluidic devices
title_full Frequency-controlled wireless passive microfluidic devices
title_fullStr Frequency-controlled wireless passive microfluidic devices
title_full_unstemmed Frequency-controlled wireless passive microfluidic devices
title_sort frequency-controlled wireless passive microfluidic devices
publishDate 2018
url http://eprints.utm.my/id/eprint/79363/1/MarwanNafeaMinjalPFKE2018.pdf
http://eprints.utm.my/id/eprint/79363/
_version_ 1643658174267392000