Fibre Bragg grating encapted with no-core fibre sensors for SRI and temperature monitoring

In this work, a Fibre Bragg grating (FBG) encapted with no-core fibre (NCF) as surrounding refractive index (SRI) and temperature sensors are practically demonstrated. A FBG with 1550 nm wavelength was attached with 5 cm length of no-core fibre (NCF) is used as SRI and temperature sensing probe. The...

Full description

Saved in:
Bibliographic Details
Main Authors: Daud, S., Amiri, I. S., Noorden, A. F. A., Ali, J., Yupapin, P.
Format: Article
Language:English
Published: Elsevier B.V. 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79731/1/JalilAli2018_FibreBraggGratingEncaptedwithNo-Core.pdf
http://eprints.utm.my/id/eprint/79731/
http://dx.doi.org/10.1016/j.rinp.2018.05.007
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
Description
Summary:In this work, a Fibre Bragg grating (FBG) encapted with no-core fibre (NCF) as surrounding refractive index (SRI) and temperature sensors are practically demonstrated. A FBG with 1550 nm wavelength was attached with 5 cm length of no-core fibre (NCF) is used as SRI and temperature sensing probe. The change of temperature and SRI induced the wavelength shift in FBG. The wavelength shift in FBG reacts directly proportional to the temperature with a sensitivity of while the sensitivity of NCF was measured as 13.13 pm °C−1.