Courtyard as a passive cooling strategy in buildings

One of the most significant current discussions in the built environment, architectural practice, theory, and procedures is “Passive Design”. It is becoming very difficult to ignore the issues of passive architectural design strategies in buildings. Recent studies emphasized the need for passive arc...

Full description

Saved in:
Bibliographic Details
Main Authors: Bulus, Markus, Hamid, Malsiah, Lim, Yaik Wah
Format: Article
Language:English
Published: Penerbit UTM Press 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/80583/1/MalsiahHamid2017_CourtyardasaPassiveCoolingStrategy.pdf
http://eprints.utm.my/id/eprint/80583/
https://dx.doi.org/10.11113/ijbes.v4.n1.159
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.80583
record_format eprints
spelling my.utm.805832019-06-27T06:08:35Z http://eprints.utm.my/id/eprint/80583/ Courtyard as a passive cooling strategy in buildings Bulus, Markus Hamid, Malsiah Lim, Yaik Wah TH Building construction One of the most significant current discussions in the built environment, architectural practice, theory, and procedures is “Passive Design”. It is becoming very difficult to ignore the issues of passive architectural design strategies in buildings. Recent studies emphasized the need for passive architectural design strategies and the application of the courtyard as a passive design strategy for cooling in buildings. Also, that the courtyard is very suitable in almost all building typologies in all the climatic zones due to its passive tendencies for cooling. Its cooling potentials can be achieved only when design requirements are not ignored. The courtyard has social, cultural, religious, and environmental benefits. Despite its abundant advantages, research effort towards courtyard design requirements is very scarce. Therefore, the main objective of this study is to investigate the design of central courtyard as a passive cooling strategy for improving indoor thermal comfort in Universiti Teknologi Malaysia (UTM) Buildings. Courtyard design requirement such as the courtyard configurations, orientation, and natural features in courtyard buildings in UTM were investigated. Besides the design variants, courtyard usage in such buildings was also examined. The methodology of this study involved the developing of a checklist based on literature for the field survey. Forty-six (46) courtyards in thirty-two (32) buildings in UTM were surveyed, and the statistical description method was used to interpret and analyzed the data. The Results of this quantitative study shows that UTM central courtyards buildings were designed based on a cautious consideration to orientation and configurations to enhance their effective passive cooling potentials, however, only two courtyards had water pools. The study concluded that courtyards in UTM buildings are creatively designed but future experimental studies to appraise their thermal performances is required, and future simulation studies can predict a better design requirement for optimum performance. Therefore, further simulation studies are recommended. Penerbit UTM Press 2017 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/80583/1/MalsiahHamid2017_CourtyardasaPassiveCoolingStrategy.pdf Bulus, Markus and Hamid, Malsiah and Lim, Yaik Wah (2017) Courtyard as a passive cooling strategy in buildings. International Journal of Built Environment and Sustainability, 4 (1). pp. 48-55. ISSN 2289-8948 https://dx.doi.org/10.11113/ijbes.v4.n1.159 DOI:10.11113/ijbes.v4.n1.159
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TH Building construction
spellingShingle TH Building construction
Bulus, Markus
Hamid, Malsiah
Lim, Yaik Wah
Courtyard as a passive cooling strategy in buildings
description One of the most significant current discussions in the built environment, architectural practice, theory, and procedures is “Passive Design”. It is becoming very difficult to ignore the issues of passive architectural design strategies in buildings. Recent studies emphasized the need for passive architectural design strategies and the application of the courtyard as a passive design strategy for cooling in buildings. Also, that the courtyard is very suitable in almost all building typologies in all the climatic zones due to its passive tendencies for cooling. Its cooling potentials can be achieved only when design requirements are not ignored. The courtyard has social, cultural, religious, and environmental benefits. Despite its abundant advantages, research effort towards courtyard design requirements is very scarce. Therefore, the main objective of this study is to investigate the design of central courtyard as a passive cooling strategy for improving indoor thermal comfort in Universiti Teknologi Malaysia (UTM) Buildings. Courtyard design requirement such as the courtyard configurations, orientation, and natural features in courtyard buildings in UTM were investigated. Besides the design variants, courtyard usage in such buildings was also examined. The methodology of this study involved the developing of a checklist based on literature for the field survey. Forty-six (46) courtyards in thirty-two (32) buildings in UTM were surveyed, and the statistical description method was used to interpret and analyzed the data. The Results of this quantitative study shows that UTM central courtyards buildings were designed based on a cautious consideration to orientation and configurations to enhance their effective passive cooling potentials, however, only two courtyards had water pools. The study concluded that courtyards in UTM buildings are creatively designed but future experimental studies to appraise their thermal performances is required, and future simulation studies can predict a better design requirement for optimum performance. Therefore, further simulation studies are recommended.
format Article
author Bulus, Markus
Hamid, Malsiah
Lim, Yaik Wah
author_facet Bulus, Markus
Hamid, Malsiah
Lim, Yaik Wah
author_sort Bulus, Markus
title Courtyard as a passive cooling strategy in buildings
title_short Courtyard as a passive cooling strategy in buildings
title_full Courtyard as a passive cooling strategy in buildings
title_fullStr Courtyard as a passive cooling strategy in buildings
title_full_unstemmed Courtyard as a passive cooling strategy in buildings
title_sort courtyard as a passive cooling strategy in buildings
publisher Penerbit UTM Press
publishDate 2017
url http://eprints.utm.my/id/eprint/80583/1/MalsiahHamid2017_CourtyardasaPassiveCoolingStrategy.pdf
http://eprints.utm.my/id/eprint/80583/
https://dx.doi.org/10.11113/ijbes.v4.n1.159
_version_ 1643658455804805120