Seismic assessment of base-isolated nuclear power plants

This research presented a numerical and experimental study on the seismic performance of first-generation base-isolated and fixed-base nuclear power plants (NPP). Three types of the base isolation system were applied to rehabilitate the first-generation nuclear power plants: frictional pendulum (FP)...

Full description

Saved in:
Bibliographic Details
Main Authors: Farmanbordar, Babak, Adnan, Azlan, Md. Tahir, Mahmood, Faridmehr, Iman
Format: Article
Published: Techno-Press 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/80772/
https://dx.doi.org/10.12989/acd.2017.2.3.211
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.80772
record_format eprints
spelling my.utm.807722019-06-27T06:23:57Z http://eprints.utm.my/id/eprint/80772/ Seismic assessment of base-isolated nuclear power plants Farmanbordar, Babak Adnan, Azlan Md. Tahir, Mahmood Faridmehr, Iman TA Engineering (General). Civil engineering (General) This research presented a numerical and experimental study on the seismic performance of first-generation base-isolated and fixed-base nuclear power plants (NPP). Three types of the base isolation system were applied to rehabilitate the first-generation nuclear power plants: frictional pendulum (FP), high-damping rubber (HDR) and lead-rubber (LR) base isolation. Also, an Excel program was proposed for the design of the abovementioned base isolators in accordance with UBC 97 and the Japan Society of Base Isolation Regulation. The seismic assessment was performed using the pushover and nonlinear time history analysis methods in accordance with the FEMA 356 regulation. To validate the adequacy of the proposed design procedure, two small-scale NPPs were constructed at Universiti Teknologi Malaysia's structural laboratory and subjected to a pushover test for two different base conditions, fixed and HDR-isolated base. The results showed that base-isolated structures achieved adequate seismic performance compared with the fixed-base one, and all three isolators led to a significant reduction in the containment's tension, overturning moment and base shear. Techno-Press 2017 Article PeerReviewed Farmanbordar, Babak and Adnan, Azlan and Md. Tahir, Mahmood and Faridmehr, Iman (2017) Seismic assessment of base-isolated nuclear power plants. Advances in Computational Design, 2 (3). pp. 211-223. ISSN 2466-0523 https://dx.doi.org/10.12989/acd.2017.2.3.211 DOI:10.12989/acd.2017.2.3.211
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Farmanbordar, Babak
Adnan, Azlan
Md. Tahir, Mahmood
Faridmehr, Iman
Seismic assessment of base-isolated nuclear power plants
description This research presented a numerical and experimental study on the seismic performance of first-generation base-isolated and fixed-base nuclear power plants (NPP). Three types of the base isolation system were applied to rehabilitate the first-generation nuclear power plants: frictional pendulum (FP), high-damping rubber (HDR) and lead-rubber (LR) base isolation. Also, an Excel program was proposed for the design of the abovementioned base isolators in accordance with UBC 97 and the Japan Society of Base Isolation Regulation. The seismic assessment was performed using the pushover and nonlinear time history analysis methods in accordance with the FEMA 356 regulation. To validate the adequacy of the proposed design procedure, two small-scale NPPs were constructed at Universiti Teknologi Malaysia's structural laboratory and subjected to a pushover test for two different base conditions, fixed and HDR-isolated base. The results showed that base-isolated structures achieved adequate seismic performance compared with the fixed-base one, and all three isolators led to a significant reduction in the containment's tension, overturning moment and base shear.
format Article
author Farmanbordar, Babak
Adnan, Azlan
Md. Tahir, Mahmood
Faridmehr, Iman
author_facet Farmanbordar, Babak
Adnan, Azlan
Md. Tahir, Mahmood
Faridmehr, Iman
author_sort Farmanbordar, Babak
title Seismic assessment of base-isolated nuclear power plants
title_short Seismic assessment of base-isolated nuclear power plants
title_full Seismic assessment of base-isolated nuclear power plants
title_fullStr Seismic assessment of base-isolated nuclear power plants
title_full_unstemmed Seismic assessment of base-isolated nuclear power plants
title_sort seismic assessment of base-isolated nuclear power plants
publisher Techno-Press
publishDate 2017
url http://eprints.utm.my/id/eprint/80772/
https://dx.doi.org/10.12989/acd.2017.2.3.211
_version_ 1643658511779889152