Optimisation of wastewater volume of single chamber biological cathodic protection system
In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and opt...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
AIDIC Servizi S.r.l.
2018
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/84379/ https://doi.org/0.3303/CET1863070 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.84379 |
---|---|
record_format |
eprints |
spelling |
my.utm.843792019-12-28T01:55:37Z http://eprints.utm.my/id/eprint/84379/ Optimisation of wastewater volume of single chamber biological cathodic protection system Wan Ali, Wan Nor Azita Azman, Anis Fitri Afira Samsudin, Mohd. Dinie Muhaimin Mohd. Zaini Makhtar, Muaz Ibrahim, Norazana Md. Kasmani, Rafiziana TP Chemical technology In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and optimise the effect of volume ratio of wastewater to the sand on biological CP performance by using Taguchi method. The maximum performance of biological CP in this study was obtained at the largest volume ratio. The orthogonal array and the signal-to-noise ratio (S/N) were employed to study the effect of volume ratio on performance of biological CP. The CP potential vs. copper sulfate electrode (CSE) was -835 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe vs. CSE was -531 mV. AIDIC Servizi S.r.l. 2018 Article PeerReviewed Wan Ali, Wan Nor Azita and Azman, Anis Fitri Afira and Samsudin, Mohd. Dinie Muhaimin and Mohd. Zaini Makhtar, Muaz and Ibrahim, Norazana and Md. Kasmani, Rafiziana (2018) Optimisation of wastewater volume of single chamber biological cathodic protection system. Chemical Engineering Transactions, 63 . pp. 415-420. ISSN 2283-9216 https://doi.org/0.3303/CET1863070 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TP Chemical technology |
spellingShingle |
TP Chemical technology Wan Ali, Wan Nor Azita Azman, Anis Fitri Afira Samsudin, Mohd. Dinie Muhaimin Mohd. Zaini Makhtar, Muaz Ibrahim, Norazana Md. Kasmani, Rafiziana Optimisation of wastewater volume of single chamber biological cathodic protection system |
description |
In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and optimise the effect of volume ratio of wastewater to the sand on biological CP performance by using Taguchi method. The maximum performance of biological CP in this study was obtained at the largest volume ratio. The orthogonal array and the signal-to-noise ratio (S/N) were employed to study the effect of volume ratio on performance of biological CP. The CP potential vs. copper sulfate electrode (CSE) was -835 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe vs. CSE was -531 mV. |
format |
Article |
author |
Wan Ali, Wan Nor Azita Azman, Anis Fitri Afira Samsudin, Mohd. Dinie Muhaimin Mohd. Zaini Makhtar, Muaz Ibrahim, Norazana Md. Kasmani, Rafiziana |
author_facet |
Wan Ali, Wan Nor Azita Azman, Anis Fitri Afira Samsudin, Mohd. Dinie Muhaimin Mohd. Zaini Makhtar, Muaz Ibrahim, Norazana Md. Kasmani, Rafiziana |
author_sort |
Wan Ali, Wan Nor Azita |
title |
Optimisation of wastewater volume of single chamber biological cathodic protection system |
title_short |
Optimisation of wastewater volume of single chamber biological cathodic protection system |
title_full |
Optimisation of wastewater volume of single chamber biological cathodic protection system |
title_fullStr |
Optimisation of wastewater volume of single chamber biological cathodic protection system |
title_full_unstemmed |
Optimisation of wastewater volume of single chamber biological cathodic protection system |
title_sort |
optimisation of wastewater volume of single chamber biological cathodic protection system |
publisher |
AIDIC Servizi S.r.l. |
publishDate |
2018 |
url |
http://eprints.utm.my/id/eprint/84379/ https://doi.org/0.3303/CET1863070 |
_version_ |
1654960079276867584 |