A structural solution for vertical expansion of single story terrace row houses in Malaysian context

Terrace Row houses are the typical townhouses in urban Malaysia with single or double storied housing units sharing common structural walls on property line with neighbours at both sides. Households always desire to expand their habitable spaces during habitation. But, these units do not provide muc...

Full description

Saved in:
Bibliographic Details
Main Authors: Saad, Sk Sakif, Khan, Tareef Hayat
Format: Article
Published: MAT Journals 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/84519/
http://matjournals.in/index.php/JOCCE/article/download/1234/883
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.84519
record_format eprints
spelling my.utm.845192020-02-29T12:33:44Z http://eprints.utm.my/id/eprint/84519/ A structural solution for vertical expansion of single story terrace row houses in Malaysian context Saad, Sk Sakif Khan, Tareef Hayat TH Building construction Terrace Row houses are the typical townhouses in urban Malaysia with single or double storied housing units sharing common structural walls on property line with neighbours at both sides. Households always desire to expand their habitable spaces during habitation. But, these units do not provide much room for expansion, at least horizontally. However, they still have the potential to expand vertically up to a limited scale through structural retrofitting. Existing weak foundation is a potential drawback for such expansion, but modern technologies such as steel I section beam, H section column, precast slab and footings, could provide an efficient solution. This study searched for basic structural solution of vertical retrofit of the single story terrace houses in urban Malaysia. Firstly, it procured space requirements for vertical expansion through existing literature. Next, three case studies were selected to represent the major typologies of single story terrace row houses. After that, potential architectural solutions for additional upper floor were produced. Then valid structural solutions of retrofit were performed. The structural retrofit design used Euro Code for the calculations. With the intension of not disturbing the current structural system, the load calculations showed that proposed vertical expansion is structurally valid. This study can give a better option for an upgraded standard of living for the inhabitants of terrace row houses if they do not want to move from their current units. MAT Journals 2017 Article PeerReviewed Saad, Sk Sakif and Khan, Tareef Hayat (2017) A structural solution for vertical expansion of single story terrace row houses in Malaysian context. Journal of Civil and Construction Engineering, 3 (1). pp. 1-6. ISSN 2457-001X http://matjournals.in/index.php/JOCCE/article/download/1234/883
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TH Building construction
spellingShingle TH Building construction
Saad, Sk Sakif
Khan, Tareef Hayat
A structural solution for vertical expansion of single story terrace row houses in Malaysian context
description Terrace Row houses are the typical townhouses in urban Malaysia with single or double storied housing units sharing common structural walls on property line with neighbours at both sides. Households always desire to expand their habitable spaces during habitation. But, these units do not provide much room for expansion, at least horizontally. However, they still have the potential to expand vertically up to a limited scale through structural retrofitting. Existing weak foundation is a potential drawback for such expansion, but modern technologies such as steel I section beam, H section column, precast slab and footings, could provide an efficient solution. This study searched for basic structural solution of vertical retrofit of the single story terrace houses in urban Malaysia. Firstly, it procured space requirements for vertical expansion through existing literature. Next, three case studies were selected to represent the major typologies of single story terrace row houses. After that, potential architectural solutions for additional upper floor were produced. Then valid structural solutions of retrofit were performed. The structural retrofit design used Euro Code for the calculations. With the intension of not disturbing the current structural system, the load calculations showed that proposed vertical expansion is structurally valid. This study can give a better option for an upgraded standard of living for the inhabitants of terrace row houses if they do not want to move from their current units.
format Article
author Saad, Sk Sakif
Khan, Tareef Hayat
author_facet Saad, Sk Sakif
Khan, Tareef Hayat
author_sort Saad, Sk Sakif
title A structural solution for vertical expansion of single story terrace row houses in Malaysian context
title_short A structural solution for vertical expansion of single story terrace row houses in Malaysian context
title_full A structural solution for vertical expansion of single story terrace row houses in Malaysian context
title_fullStr A structural solution for vertical expansion of single story terrace row houses in Malaysian context
title_full_unstemmed A structural solution for vertical expansion of single story terrace row houses in Malaysian context
title_sort structural solution for vertical expansion of single story terrace row houses in malaysian context
publisher MAT Journals
publishDate 2017
url http://eprints.utm.my/id/eprint/84519/
http://matjournals.in/index.php/JOCCE/article/download/1234/883
_version_ 1662754272008208384