Analytical modeling of conventional and miniaturization three-section branch-line couplers
Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of b...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Korean Institute of Electrical Engineers
2018
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/85989/ http://dx.doi.org/10.5370/JEET.2018.13.2.858 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.85989 |
---|---|
record_format |
eprints |
spelling |
my.utm.859892020-08-30T08:48:56Z http://eprints.utm.my/id/eprint/85989/ Analytical modeling of conventional and miniaturization three-section branch-line couplers You, Kok Yeow Al-Areqi, Nadera Chong, Jaw Chung Lee, Kim Yee Cheng, Ee Meng Lee, Yeng Seng TK Electrical engineering. Electronics Nuclear engineering Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of broadband S-parameters analysis. In addition, a bandwidth extension and miniaturization of three-section branch-line coupler using slow-wave and meandering line structures were designed. The modified coupler, which is able to operate within frequencies from 1.5 to 3.32 GHz has been fabricated, tested and compared. A bandwidth extension of 600 MHz and 53% reduced size of the modified coupler have been achieved compared to a conventional coupler. The modified coupler has roughly insertion loss and coupling of -4 dB and -3.2 dB, while the isolation and return loss, respectively less than -14 dB with fractional bandwidth of 77 %, as well as phase imbalances less than 2° over the operating bandwidth. Overall, the derived analytical model, simulation and measurement results demonstrated a good agreement. Korean Institute of Electrical Engineers 2018-03 Article PeerReviewed You, Kok Yeow and Al-Areqi, Nadera and Chong, Jaw Chung and Lee, Kim Yee and Cheng, Ee Meng and Lee, Yeng Seng (2018) Analytical modeling of conventional and miniaturization three-section branch-line couplers. Journal of Electrical Engineering and Technology, 13 (2). pp. 858-867. ISSN 1975-0102 http://dx.doi.org/10.5370/JEET.2018.13.2.858 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering You, Kok Yeow Al-Areqi, Nadera Chong, Jaw Chung Lee, Kim Yee Cheng, Ee Meng Lee, Yeng Seng Analytical modeling of conventional and miniaturization three-section branch-line couplers |
description |
Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of broadband S-parameters analysis. In addition, a bandwidth extension and miniaturization of three-section branch-line coupler using slow-wave and meandering line structures were designed. The modified coupler, which is able to operate within frequencies from 1.5 to 3.32 GHz has been fabricated, tested and compared. A bandwidth extension of 600 MHz and 53% reduced size of the modified coupler have been achieved compared to a conventional coupler. The modified coupler has roughly insertion loss and coupling of -4 dB and -3.2 dB, while the isolation and return loss, respectively less than -14 dB with fractional bandwidth of 77 %, as well as phase imbalances less than 2° over the operating bandwidth. Overall, the derived analytical model, simulation and measurement results demonstrated a good agreement. |
format |
Article |
author |
You, Kok Yeow Al-Areqi, Nadera Chong, Jaw Chung Lee, Kim Yee Cheng, Ee Meng Lee, Yeng Seng |
author_facet |
You, Kok Yeow Al-Areqi, Nadera Chong, Jaw Chung Lee, Kim Yee Cheng, Ee Meng Lee, Yeng Seng |
author_sort |
You, Kok Yeow |
title |
Analytical modeling of conventional and miniaturization three-section branch-line couplers |
title_short |
Analytical modeling of conventional and miniaturization three-section branch-line couplers |
title_full |
Analytical modeling of conventional and miniaturization three-section branch-line couplers |
title_fullStr |
Analytical modeling of conventional and miniaturization three-section branch-line couplers |
title_full_unstemmed |
Analytical modeling of conventional and miniaturization three-section branch-line couplers |
title_sort |
analytical modeling of conventional and miniaturization three-section branch-line couplers |
publisher |
Korean Institute of Electrical Engineers |
publishDate |
2018 |
url |
http://eprints.utm.my/id/eprint/85989/ http://dx.doi.org/10.5370/JEET.2018.13.2.858 |
_version_ |
1677781114301710336 |