Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section
Conventional pad footing with temporary formwork using plywood or timber is not environmentally friendly and does not contribute to the strength of the foundation. This paper proposed the use of cold-formed lipped channel sections in pre-fabricated pad footings to increase the load capacity and spee...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Springer Verlag
2019
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/87691/ http://dx.doi.org/10.1007/s13369-019-04079-z |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.87691 |
---|---|
record_format |
eprints |
spelling |
my.utm.876912020-11-30T13:08:53Z http://eprints.utm.my/id/eprint/87691/ Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section Md. Tahir, Mahmood Mohammadhosseini, Hossein Alyousef, Rayed Wong, Kah Leong Salih, Musab N. A. TA Engineering (General). Civil engineering (General) Conventional pad footing with temporary formwork using plywood or timber is not environmentally friendly and does not contribute to the strength of the foundation. This paper proposed the use of cold-formed lipped channel sections in pre-fabricated pad footings to increase the load capacity and speed up the construction time in addition to the reduction in timber used as the formwork, which leads to eco-friendly construction. An experimental investigation on the proposed pad footing was carried out in this study. Twelve specimens were made and tested with the axial compression force applied to the footing through the column stump to investigate the failure criterion of the footing due to cracks, overall deformation, and load-carrying capacity. All notable failures on the footing specimens were carefully observed and reported. The findings from the experimental investigations revealed a reasonable agreement with the theoretical models calculated based on CEN-EC2. The pre-fabricated composite pad footing demonstrated significant increment in strength as the footing was strengthened using steel sections, instead of steel bar, in comparison with that of conventional pad footing. The study revealed that the proposed pad footing system has the potential to be used as a structural component in mid-rise light-framed steel structures. Springer Verlag 2019-10 Article PeerReviewed Md. Tahir, Mahmood and Mohammadhosseini, Hossein and Alyousef, Rayed and Wong, Kah Leong and Salih, Musab N. A. (2019) Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section. Arabian Journal for Science and Engineering, 44 (10). pp. 8225-8238. ISSN 2193-567X http://dx.doi.org/10.1007/s13369-019-04079-z |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Md. Tahir, Mahmood Mohammadhosseini, Hossein Alyousef, Rayed Wong, Kah Leong Salih, Musab N. A. Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section |
description |
Conventional pad footing with temporary formwork using plywood or timber is not environmentally friendly and does not contribute to the strength of the foundation. This paper proposed the use of cold-formed lipped channel sections in pre-fabricated pad footings to increase the load capacity and speed up the construction time in addition to the reduction in timber used as the formwork, which leads to eco-friendly construction. An experimental investigation on the proposed pad footing was carried out in this study. Twelve specimens were made and tested with the axial compression force applied to the footing through the column stump to investigate the failure criterion of the footing due to cracks, overall deformation, and load-carrying capacity. All notable failures on the footing specimens were carefully observed and reported. The findings from the experimental investigations revealed a reasonable agreement with the theoretical models calculated based on CEN-EC2. The pre-fabricated composite pad footing demonstrated significant increment in strength as the footing was strengthened using steel sections, instead of steel bar, in comparison with that of conventional pad footing. The study revealed that the proposed pad footing system has the potential to be used as a structural component in mid-rise light-framed steel structures. |
format |
Article |
author |
Md. Tahir, Mahmood Mohammadhosseini, Hossein Alyousef, Rayed Wong, Kah Leong Salih, Musab N. A. |
author_facet |
Md. Tahir, Mahmood Mohammadhosseini, Hossein Alyousef, Rayed Wong, Kah Leong Salih, Musab N. A. |
author_sort |
Md. Tahir, Mahmood |
title |
Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section |
title_short |
Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section |
title_full |
Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section |
title_fullStr |
Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section |
title_full_unstemmed |
Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section |
title_sort |
performance evaluation of pre-fabricated footing using cold-formed steel of lipped c-channel section |
publisher |
Springer Verlag |
publishDate |
2019 |
url |
http://eprints.utm.my/id/eprint/87691/ http://dx.doi.org/10.1007/s13369-019-04079-z |
_version_ |
1685578974765252608 |