Conventional pad footing with temporary formwork using plywood or timber is not environmentally friendly and does not contribute to the strength of the foundation. This paper proposed the use of cold-formed lipped channel sections in pre-fabricated pad footings to increase the load capacity and spee...

Full description

Saved in:
Bibliographic Details
Main Authors: Md. Tahir, Mahmood, Mohammadhosseini, Hossein, Alyousef, Rayed, Wong, Kah Leong, Salih, Musab N. A.
Format: Article
Published: Springer Verlag 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/87691/
http://dx.doi.org/10.1007/s13369-019-04079-z
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.87691
record_format eprints
spelling my.utm.876912020-11-30T13:08:53Z http://eprints.utm.my/id/eprint/87691/ Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section Md. Tahir, Mahmood Mohammadhosseini, Hossein Alyousef, Rayed Wong, Kah Leong Salih, Musab N. A. TA Engineering (General). Civil engineering (General) Conventional pad footing with temporary formwork using plywood or timber is not environmentally friendly and does not contribute to the strength of the foundation. This paper proposed the use of cold-formed lipped channel sections in pre-fabricated pad footings to increase the load capacity and speed up the construction time in addition to the reduction in timber used as the formwork, which leads to eco-friendly construction. An experimental investigation on the proposed pad footing was carried out in this study. Twelve specimens were made and tested with the axial compression force applied to the footing through the column stump to investigate the failure criterion of the footing due to cracks, overall deformation, and load-carrying capacity. All notable failures on the footing specimens were carefully observed and reported. The findings from the experimental investigations revealed a reasonable agreement with the theoretical models calculated based on CEN-EC2. The pre-fabricated composite pad footing demonstrated significant increment in strength as the footing was strengthened using steel sections, instead of steel bar, in comparison with that of conventional pad footing. The study revealed that the proposed pad footing system has the potential to be used as a structural component in mid-rise light-framed steel structures. Springer Verlag 2019-10 Article PeerReviewed Md. Tahir, Mahmood and Mohammadhosseini, Hossein and Alyousef, Rayed and Wong, Kah Leong and Salih, Musab N. A. (2019) Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section. Arabian Journal for Science and Engineering, 44 (10). pp. 8225-8238. ISSN 2193-567X http://dx.doi.org/10.1007/s13369-019-04079-z
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Md. Tahir, Mahmood
Mohammadhosseini, Hossein
Alyousef, Rayed
Wong, Kah Leong
Salih, Musab N. A.
Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section
description Conventional pad footing with temporary formwork using plywood or timber is not environmentally friendly and does not contribute to the strength of the foundation. This paper proposed the use of cold-formed lipped channel sections in pre-fabricated pad footings to increase the load capacity and speed up the construction time in addition to the reduction in timber used as the formwork, which leads to eco-friendly construction. An experimental investigation on the proposed pad footing was carried out in this study. Twelve specimens were made and tested with the axial compression force applied to the footing through the column stump to investigate the failure criterion of the footing due to cracks, overall deformation, and load-carrying capacity. All notable failures on the footing specimens were carefully observed and reported. The findings from the experimental investigations revealed a reasonable agreement with the theoretical models calculated based on CEN-EC2. The pre-fabricated composite pad footing demonstrated significant increment in strength as the footing was strengthened using steel sections, instead of steel bar, in comparison with that of conventional pad footing. The study revealed that the proposed pad footing system has the potential to be used as a structural component in mid-rise light-framed steel structures.
format Article
author Md. Tahir, Mahmood
Mohammadhosseini, Hossein
Alyousef, Rayed
Wong, Kah Leong
Salih, Musab N. A.
author_facet Md. Tahir, Mahmood
Mohammadhosseini, Hossein
Alyousef, Rayed
Wong, Kah Leong
Salih, Musab N. A.
author_sort Md. Tahir, Mahmood
title Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section
title_short Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section
title_full Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section
title_fullStr Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section
title_full_unstemmed Performance evaluation of pre-fabricated footing using cold-formed steel of lipped C-channel section
title_sort performance evaluation of pre-fabricated footing using cold-formed steel of lipped c-channel section
publisher Springer Verlag
publishDate 2019
url http://eprints.utm.my/id/eprint/87691/
http://dx.doi.org/10.1007/s13369-019-04079-z
_version_ 1685578974765252608