Development of flexible pneumatic rehabilitation actuator for knee injury
McKibben muscle actuator or pneumatic muscle has been introduced for many decades. Only by filling with the compressed pneumatic air, the McKibben muscle actuator can generate the contraction force. In other hand, one of the injuries that involves rehabilitation is anterior cruciate ligament tear, e...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
The Mattingley Publishing Co. Inc.
2020
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/90122/ https://www.testmagzine.biz/index.php/testmagzine/issue/view/8 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.90122 |
---|---|
record_format |
eprints |
spelling |
my.utm.901222021-03-31T06:21:25Z http://eprints.utm.my/id/eprint/90122/ Development of flexible pneumatic rehabilitation actuator for knee injury Mohd. Aliff, Mohd. Aliff Fitri Danieal, Fitri Danieal Mohamed, Mohd. Firdaus Ahmad 'Athif, Ahmad 'Athif Tetsuya, Akagi Nor Samsiah, Nor Samsiah T Technology (General) McKibben muscle actuator or pneumatic muscle has been introduced for many decades. Only by filling with the compressed pneumatic air, the McKibben muscle actuator can generate the contraction force. In other hand, one of the injuries that involves rehabilitation is anterior cruciate ligament tear, either completely or partially torn. Rehabilitation is one of the procedures or treatments for anterior cruciate ligament patients to reduce the time of their healing and to restore joint movement and muscle strength. Besides, in hospitals, the use of soft actuators for knee rehabilitation processes is still lacking. Generally, recovery devices either in hospitals or in rehabilitation centers use iron and steels that are uncomfortable and hard for patients to use. Therefore, in this paper, the rehabilitation device that is comfortable and lightweight based on the application of McKibben artificial muscle and pneumatic soft actuators is proposed and presented. The patient should wear a recovery device with an accelerometer sensor attached to it while performing basic movements of the knee during recovery. From the experimental results and the data from the accelerometer, it is trusted that the rehabilitation device can help the recovery process and offers more data than regular technique to help patients perform normal knee movements. The Mattingley Publishing Co. Inc. 2020 Article PeerReviewed Mohd. Aliff, Mohd. Aliff and Fitri Danieal, Fitri Danieal and Mohamed, Mohd. Firdaus and Ahmad 'Athif, Ahmad 'Athif and Tetsuya, Akagi and Nor Samsiah, Nor Samsiah (2020) Development of flexible pneumatic rehabilitation actuator for knee injury. Test Engineering And Management, 83 . pp. 12849-12855. ISSN 0193-4120 https://www.testmagzine.biz/index.php/testmagzine/issue/view/8 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Mohd. Aliff, Mohd. Aliff Fitri Danieal, Fitri Danieal Mohamed, Mohd. Firdaus Ahmad 'Athif, Ahmad 'Athif Tetsuya, Akagi Nor Samsiah, Nor Samsiah Development of flexible pneumatic rehabilitation actuator for knee injury |
description |
McKibben muscle actuator or pneumatic muscle has been introduced for many decades. Only by filling with the compressed pneumatic air, the McKibben muscle actuator can generate the contraction force. In other hand, one of the injuries that involves rehabilitation is anterior cruciate ligament tear, either completely or partially torn. Rehabilitation is one of the procedures or treatments for anterior cruciate ligament patients to reduce the time of their healing and to restore joint movement and muscle strength. Besides, in hospitals, the use of soft actuators for knee rehabilitation processes is still lacking. Generally, recovery devices either in hospitals or in rehabilitation centers use iron and steels that are uncomfortable and hard for patients to use. Therefore, in this paper, the rehabilitation device that is comfortable and lightweight based on the application of McKibben artificial muscle and pneumatic soft actuators is proposed and presented. The patient should wear a recovery device with an accelerometer sensor attached to it while performing basic movements of the knee during recovery. From the experimental results and the data from the accelerometer, it is trusted that the rehabilitation device can help the recovery process and offers more data than regular technique to help patients perform normal knee movements. |
format |
Article |
author |
Mohd. Aliff, Mohd. Aliff Fitri Danieal, Fitri Danieal Mohamed, Mohd. Firdaus Ahmad 'Athif, Ahmad 'Athif Tetsuya, Akagi Nor Samsiah, Nor Samsiah |
author_facet |
Mohd. Aliff, Mohd. Aliff Fitri Danieal, Fitri Danieal Mohamed, Mohd. Firdaus Ahmad 'Athif, Ahmad 'Athif Tetsuya, Akagi Nor Samsiah, Nor Samsiah |
author_sort |
Mohd. Aliff, Mohd. Aliff |
title |
Development of flexible pneumatic rehabilitation actuator for knee injury |
title_short |
Development of flexible pneumatic rehabilitation actuator for knee injury |
title_full |
Development of flexible pneumatic rehabilitation actuator for knee injury |
title_fullStr |
Development of flexible pneumatic rehabilitation actuator for knee injury |
title_full_unstemmed |
Development of flexible pneumatic rehabilitation actuator for knee injury |
title_sort |
development of flexible pneumatic rehabilitation actuator for knee injury |
publisher |
The Mattingley Publishing Co. Inc. |
publishDate |
2020 |
url |
http://eprints.utm.my/id/eprint/90122/ https://www.testmagzine.biz/index.php/testmagzine/issue/view/8 |
_version_ |
1696976264586330112 |