Uric acid detection in visible spectrum

The measurement of uric acid based on the optical absorption at visible light spectrum is investigated and tested. Sensing in the visible region was conducted for determination of suitable wavelength that produces high sensitivity and accuracy performance based on the Beer-Lambert law calculation. I...

Full description

Saved in:
Bibliographic Details
Main Authors: Yaacob, Afiqah, Ngajikin, Nor Hafizah, Che Abd. Rashid, Nurfatihah, Ali, Siti Hajar Aminah, Yaacob, Maslina, Isaak, Suhaila, Cholan, Noran Azizan
Format: Article
Language:English
Published: Universitas Ahmad Dahlan 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/91582/1/SuhailaIsaak2020_UricAcidDetectioninVisibleSpectrum.pdf
http://eprints.utm.my/id/eprint/91582/
http://dx.doi.org/10.12928/TELKOMNIKA.V18I4.14993
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.91582
record_format eprints
spelling my.utm.915822021-07-14T08:16:18Z http://eprints.utm.my/id/eprint/91582/ Uric acid detection in visible spectrum Yaacob, Afiqah Ngajikin, Nor Hafizah Che Abd. Rashid, Nurfatihah Ali, Siti Hajar Aminah Yaacob, Maslina Isaak, Suhaila Cholan, Noran Azizan TK Electrical engineering. Electronics Nuclear engineering The measurement of uric acid based on the optical absorption at visible light spectrum is investigated and tested. Sensing in the visible region was conducted for determination of suitable wavelength that produces high sensitivity and accuracy performance based on the Beer-Lambert law calculation. In this work, the uric acid is detected by detecting sodium urate as a product of chemical reaction between uric acid with sodium hydroxide buffer. The setup has been tested for uric acid concentration ranging from 15 mg/dL to 85 mg/dL. Three wavelengths have been analyzed which are 460 nm, 525 nm and 630 nm. Measured data at 460nm wavelength exhibits the highest sensitivity, which is 0.0012 (mg/dL)-with 86.51% accuracy. Detection of uric acid at visible light spectrum offers a low-cost sensor based on visible LEDs and photodiode is possible to be realized. Universitas Ahmad Dahlan 2020 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/91582/1/SuhailaIsaak2020_UricAcidDetectioninVisibleSpectrum.pdf Yaacob, Afiqah and Ngajikin, Nor Hafizah and Che Abd. Rashid, Nurfatihah and Ali, Siti Hajar Aminah and Yaacob, Maslina and Isaak, Suhaila and Cholan, Noran Azizan (2020) Uric acid detection in visible spectrum. Telkomnika (Telecommunication Computing Electronics and Control), 18 (4). pp. 2035-2041. ISSN 1693-6930 http://dx.doi.org/10.12928/TELKOMNIKA.V18I4.14993
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yaacob, Afiqah
Ngajikin, Nor Hafizah
Che Abd. Rashid, Nurfatihah
Ali, Siti Hajar Aminah
Yaacob, Maslina
Isaak, Suhaila
Cholan, Noran Azizan
Uric acid detection in visible spectrum
description The measurement of uric acid based on the optical absorption at visible light spectrum is investigated and tested. Sensing in the visible region was conducted for determination of suitable wavelength that produces high sensitivity and accuracy performance based on the Beer-Lambert law calculation. In this work, the uric acid is detected by detecting sodium urate as a product of chemical reaction between uric acid with sodium hydroxide buffer. The setup has been tested for uric acid concentration ranging from 15 mg/dL to 85 mg/dL. Three wavelengths have been analyzed which are 460 nm, 525 nm and 630 nm. Measured data at 460nm wavelength exhibits the highest sensitivity, which is 0.0012 (mg/dL)-with 86.51% accuracy. Detection of uric acid at visible light spectrum offers a low-cost sensor based on visible LEDs and photodiode is possible to be realized.
format Article
author Yaacob, Afiqah
Ngajikin, Nor Hafizah
Che Abd. Rashid, Nurfatihah
Ali, Siti Hajar Aminah
Yaacob, Maslina
Isaak, Suhaila
Cholan, Noran Azizan
author_facet Yaacob, Afiqah
Ngajikin, Nor Hafizah
Che Abd. Rashid, Nurfatihah
Ali, Siti Hajar Aminah
Yaacob, Maslina
Isaak, Suhaila
Cholan, Noran Azizan
author_sort Yaacob, Afiqah
title Uric acid detection in visible spectrum
title_short Uric acid detection in visible spectrum
title_full Uric acid detection in visible spectrum
title_fullStr Uric acid detection in visible spectrum
title_full_unstemmed Uric acid detection in visible spectrum
title_sort uric acid detection in visible spectrum
publisher Universitas Ahmad Dahlan
publishDate 2020
url http://eprints.utm.my/id/eprint/91582/1/SuhailaIsaak2020_UricAcidDetectioninVisibleSpectrum.pdf
http://eprints.utm.my/id/eprint/91582/
http://dx.doi.org/10.12928/TELKOMNIKA.V18I4.14993
_version_ 1706956969346072576