Quality improvement of plastic injection molded product using doe and taguchi techniques

Multi-cavity injection moulding process is challenging due to increasing complexity in design and higher precision requirement. Quality defects need to be addressed effectively and systematically. This paper reports an investigation based on a case study company producing consumable injection moulde...

Full description

Saved in:
Bibliographic Details
Main Authors: Toh, H. T., Hassan, Adnan
Format: Conference or Workshop Item
Published: 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/94458/
http://dx.doi.org/10.1007/978-981-16-0736-3_28
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.94458
record_format eprints
spelling my.utm.944582022-03-31T15:41:21Z http://eprints.utm.my/id/eprint/94458/ Quality improvement of plastic injection molded product using doe and taguchi techniques Toh, H. T. Hassan, Adnan TJ Mechanical engineering and machinery Multi-cavity injection moulding process is challenging due to increasing complexity in design and higher precision requirement. Quality defects need to be addressed effectively and systematically. This paper reports an investigation based on a case study company producing consumable injection moulded parts for medical application. The current process suffers high reject rate due to excessive warpage and gate flash where the company lose about 17% of daily production. This has significantly effected the company’s productivity. The objective of this study is to minimize warpage and gate flash of the injected moulded polyvinyl chloride (PVC) parts. Significant process parameters contributing to both warpage and gate flash defects are identified. The study also attempted to search for an optimum setting such that it could be used as a guide to concurrently improve the warpage and gate flash. A fractional factorial design and Response Surface Methodology (RSM) techniques were used. An optimum parameter setting is proposed through an overlaid contour plot that combine the two responses. The recommended feasible setting leading to an optimum performance are -1.6 for holding pressure and 0.6 for mould temperature (coded values). Practical validation indicates a significant reduction in rejection rate. This study shoud be further extended to refine the proposed regression model. 2021 Conference or Workshop Item PeerReviewed Toh, H. T. and Hassan, Adnan (2021) Quality improvement of plastic injection molded product using doe and taguchi techniques. In: 2nd International Conference on Experimental and Computational Mechanics in Engineering, ICECME 2020, 13 - 14 October 2020, Banda Aceh, Indonesia. http://dx.doi.org/10.1007/978-981-16-0736-3_28
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Toh, H. T.
Hassan, Adnan
Quality improvement of plastic injection molded product using doe and taguchi techniques
description Multi-cavity injection moulding process is challenging due to increasing complexity in design and higher precision requirement. Quality defects need to be addressed effectively and systematically. This paper reports an investigation based on a case study company producing consumable injection moulded parts for medical application. The current process suffers high reject rate due to excessive warpage and gate flash where the company lose about 17% of daily production. This has significantly effected the company’s productivity. The objective of this study is to minimize warpage and gate flash of the injected moulded polyvinyl chloride (PVC) parts. Significant process parameters contributing to both warpage and gate flash defects are identified. The study also attempted to search for an optimum setting such that it could be used as a guide to concurrently improve the warpage and gate flash. A fractional factorial design and Response Surface Methodology (RSM) techniques were used. An optimum parameter setting is proposed through an overlaid contour plot that combine the two responses. The recommended feasible setting leading to an optimum performance are -1.6 for holding pressure and 0.6 for mould temperature (coded values). Practical validation indicates a significant reduction in rejection rate. This study shoud be further extended to refine the proposed regression model.
format Conference or Workshop Item
author Toh, H. T.
Hassan, Adnan
author_facet Toh, H. T.
Hassan, Adnan
author_sort Toh, H. T.
title Quality improvement of plastic injection molded product using doe and taguchi techniques
title_short Quality improvement of plastic injection molded product using doe and taguchi techniques
title_full Quality improvement of plastic injection molded product using doe and taguchi techniques
title_fullStr Quality improvement of plastic injection molded product using doe and taguchi techniques
title_full_unstemmed Quality improvement of plastic injection molded product using doe and taguchi techniques
title_sort quality improvement of plastic injection molded product using doe and taguchi techniques
publishDate 2021
url http://eprints.utm.my/id/eprint/94458/
http://dx.doi.org/10.1007/978-981-16-0736-3_28
_version_ 1729703175020085248