Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate

This paper examined the performance of a thermo-electric air duct system (TE-AD), which employs the thermo-electric module (TEMs) inside an air duct for providing thermal comfort in Malaysian environment. Twenty human subjects were exposed to test room equipped with TE-AD system operating at six dif...

Full description

Saved in:
Bibliographic Details
Main Authors: irshad, kashif, Habib, Khairul, basrawi, firdaus, Nagarajan, T, saidur, R, Saha, Bidyut B.
Format: Article
Published: Elsevier 2015
Subjects:
Online Access:http://eprints.utp.edu.my/11760/1/Habib%20ATE.pdf
http://eprints.utp.edu.my/11760/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
id my.utp.eprints.11760
record_format eprints
spelling my.utp.eprints.117602016-10-07T01:42:40Z Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate irshad, kashif Habib, Khairul basrawi, firdaus Nagarajan, T saidur, R Saha, Bidyut B. TJ Mechanical engineering and machinery This paper examined the performance of a thermo-electric air duct system (TE-AD), which employs the thermo-electric module (TEMs) inside an air duct for providing thermal comfort in Malaysian environment. Twenty human subjects were exposed to test room equipped with TE-AD system operating at six different input current supply from 2 A to 7 A. Both objective and subjective measurements were carried out. Results show that with the increment of input current supply to the TE-AD system, subject's thermal response related to indoor condition of test room shifted fromwarm to neutral. Optimum performance of the TE-AD system was obtained at the input current supply of 6 A, more than 80% of subjects responded in the range of ±1 and meets ASHARE standards of acceptability criteria. Further increase in input current supply deteriorates the cooling performance of the TE-AD system. Economic comparison of the TE-AD system with the existing air conditioning system shows that economic saving of US$ 127.34/year can be achieved with additional benefits of Freon free, convenient installation, no moving part and reliable operation. Elsevier 2015-09-05 Article PeerReviewed application/pdf http://eprints.utp.edu.my/11760/1/Habib%20ATE.pdf irshad, kashif and Habib, Khairul and basrawi, firdaus and Nagarajan, T and saidur, R and Saha, Bidyut B. (2015) Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate. Applied Thermal Engineering, 91 . pp. 1141-1155. ISSN 13594311 http://eprints.utp.edu.my/11760/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
irshad, kashif
Habib, Khairul
basrawi, firdaus
Nagarajan, T
saidur, R
Saha, Bidyut B.
Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate
description This paper examined the performance of a thermo-electric air duct system (TE-AD), which employs the thermo-electric module (TEMs) inside an air duct for providing thermal comfort in Malaysian environment. Twenty human subjects were exposed to test room equipped with TE-AD system operating at six different input current supply from 2 A to 7 A. Both objective and subjective measurements were carried out. Results show that with the increment of input current supply to the TE-AD system, subject's thermal response related to indoor condition of test room shifted fromwarm to neutral. Optimum performance of the TE-AD system was obtained at the input current supply of 6 A, more than 80% of subjects responded in the range of ±1 and meets ASHARE standards of acceptability criteria. Further increase in input current supply deteriorates the cooling performance of the TE-AD system. Economic comparison of the TE-AD system with the existing air conditioning system shows that economic saving of US$ 127.34/year can be achieved with additional benefits of Freon free, convenient installation, no moving part and reliable operation.
format Article
author irshad, kashif
Habib, Khairul
basrawi, firdaus
Nagarajan, T
saidur, R
Saha, Bidyut B.
author_facet irshad, kashif
Habib, Khairul
basrawi, firdaus
Nagarajan, T
saidur, R
Saha, Bidyut B.
author_sort irshad, kashif
title Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate
title_short Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate
title_full Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate
title_fullStr Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate
title_full_unstemmed Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate
title_sort thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate
publisher Elsevier
publishDate 2015
url http://eprints.utp.edu.my/11760/1/Habib%20ATE.pdf
http://eprints.utp.edu.my/11760/
_version_ 1738655978531848192