The source of the somatosensory evoked field (SEF), is one of the standard paradigm used for pre surgical mapping of brain tumor. The surgical management of the tumors requires a detailed mapping of cortical regions involved in sensory functions to avoid further deterioration of function. We investi...

Full description

Saved in:
Bibliographic Details
Main Authors: Elaina, Nor Safira, Malik, Aamir Saeed, Badruddin , Nasreen, Abdullah, Jafri Malin, Reza, Faruque
Format: Conference or Workshop Item
Published: 2015
Subjects:
Online Access:http://eprints.utp.edu.my/11835/1/Somatosensory%20source%20localization%20for%20the%20magnetoencephalography%20%28MEG%29%20inverse%20problem%20in%20patients%20with%20brain%20tumor.pdf
http://eprints.utp.edu.my/11835/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
id my.utp.eprints.11835
record_format eprints
spelling my.utp.eprints.118352016-10-07T01:42:43Z Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor Elaina, Nor Safira Malik, Aamir Saeed Badruddin , Nasreen Abdullah, Jafri Malin Reza, Faruque Q Science (General) T Technology (General) The source of the somatosensory evoked field (SEF), is one of the standard paradigm used for pre surgical mapping of brain tumor. The surgical management of the tumors requires a detailed mapping of cortical regions involved in sensory functions to avoid further deterioration of function. We investigated the early component of somatosensory evoked field (SEF) between 20-25 ms for the somatosensory response between normal and brain tumor patients and deflections in peak latency of N20M may be occurred due to present of tumor. The N20M somatosensory evoked field (SEF) corresponding electrical median nerve stimulation was measured using whole head 306 ELEKTA Neuromag® MEG system. The MEG was accurately localize the origin of intraneuronal electric currents that contribute to extra cranial magnetic fields by fitting to an equivalent current dipole model (ECD). In the present study, the equivalent current dipole model is used to determine the source location of somatosensory cortex (SI) displacement due to the tumor in the central sulcus. The ECD inverse problem method had shown that the N20M SEF for unaffected hemisphere and normal subjects were located in the primary somatosensory cortex (SI) and for the affected hemisphere, the ECD source had deflected in few millimeters far from S1 cortex. We have confirmed that, the enlarged of ECD strength also occurred due to the tumor and the difference of N20M in brain tumor either in AH or UH indicated the neural pathways to the response to N20M in normal subjects might be independent. 2015-03 Conference or Workshop Item PeerReviewed application/pdf http://eprints.utp.edu.my/11835/1/Somatosensory%20source%20localization%20for%20the%20magnetoencephalography%20%28MEG%29%20inverse%20problem%20in%20patients%20with%20brain%20tumor.pdf Elaina, Nor Safira and Malik, Aamir Saeed and Badruddin , Nasreen and Abdullah, Jafri Malin and Reza, Faruque (2015) Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor. In: 2015 2nd International Conference on Biomedical Engineering (ICoBE). http://eprints.utp.edu.my/11835/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic Q Science (General)
T Technology (General)
spellingShingle Q Science (General)
T Technology (General)
Elaina, Nor Safira
Malik, Aamir Saeed
Badruddin , Nasreen
Abdullah, Jafri Malin
Reza, Faruque
Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor
description The source of the somatosensory evoked field (SEF), is one of the standard paradigm used for pre surgical mapping of brain tumor. The surgical management of the tumors requires a detailed mapping of cortical regions involved in sensory functions to avoid further deterioration of function. We investigated the early component of somatosensory evoked field (SEF) between 20-25 ms for the somatosensory response between normal and brain tumor patients and deflections in peak latency of N20M may be occurred due to present of tumor. The N20M somatosensory evoked field (SEF) corresponding electrical median nerve stimulation was measured using whole head 306 ELEKTA Neuromag® MEG system. The MEG was accurately localize the origin of intraneuronal electric currents that contribute to extra cranial magnetic fields by fitting to an equivalent current dipole model (ECD). In the present study, the equivalent current dipole model is used to determine the source location of somatosensory cortex (SI) displacement due to the tumor in the central sulcus. The ECD inverse problem method had shown that the N20M SEF for unaffected hemisphere and normal subjects were located in the primary somatosensory cortex (SI) and for the affected hemisphere, the ECD source had deflected in few millimeters far from S1 cortex. We have confirmed that, the enlarged of ECD strength also occurred due to the tumor and the difference of N20M in brain tumor either in AH or UH indicated the neural pathways to the response to N20M in normal subjects might be independent.
format Conference or Workshop Item
author Elaina, Nor Safira
Malik, Aamir Saeed
Badruddin , Nasreen
Abdullah, Jafri Malin
Reza, Faruque
author_facet Elaina, Nor Safira
Malik, Aamir Saeed
Badruddin , Nasreen
Abdullah, Jafri Malin
Reza, Faruque
author_sort Elaina, Nor Safira
title Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor
title_short Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor
title_full Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor
title_fullStr Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor
title_full_unstemmed Somatosensory source localization for the magnetoencephalography (MEG) inverse problem in patients with brain tumor
title_sort somatosensory source localization for the magnetoencephalography (meg) inverse problem in patients with brain tumor
publishDate 2015
url http://eprints.utp.edu.my/11835/1/Somatosensory%20source%20localization%20for%20the%20magnetoencephalography%20%28MEG%29%20inverse%20problem%20in%20patients%20with%20brain%20tumor.pdf
http://eprints.utp.edu.my/11835/
_version_ 1738655984912433152