Image histogram and FFT based critical study on noise in fluorescence microscope images
The immune system is a complex network of highly specialized cells (such as lymphocytes) and organs. All of these cells work together to reduce infection (antigens) such as bacteria, virus or tumor cell from the body. Biologic Response Modifiers (BRM) also known as immunotherapy, is a type of treatm...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012031804&doi=10.1109%2fICIAS.2016.7824039&partnerID=40&md5=3bb91943b41bea4a9523678223eb5581 http://eprints.utp.edu.my/20176/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Petronas |
id |
my.utp.eprints.20176 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.201762018-04-22T14:44:33Z Image histogram and FFT based critical study on noise in fluorescence microscope images Mkayes, A.A. Saad, N.M. Faye, I. Walter, N. The immune system is a complex network of highly specialized cells (such as lymphocytes) and organs. All of these cells work together to reduce infection (antigens) such as bacteria, virus or tumor cell from the body. Biologic Response Modifiers (BRM) also known as immunotherapy, is a type of treatment which mobilizes and triggers the immune system of the body. This research work provides a description of noise nature of immunofluorescence microscope images. Thus, the study leads to determine the type of noise and choose the filter which best fit the noise presented in fluorescence microscope images. Image histogram and Fast Fourier Transform (FFT) have been applied on blood samples. However, the results show that the Gaussian noise is found in this kind of images. CLAHE filter has been applied to these images. The results obtained from CLAHE demonstrate the ability for this filter to deal with this kind of images. © 2016 IEEE. Institute of Electrical and Electronics Engineers Inc. 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012031804&doi=10.1109%2fICIAS.2016.7824039&partnerID=40&md5=3bb91943b41bea4a9523678223eb5581 Mkayes, A.A. and Saad, N.M. and Faye, I. and Walter, N. (2017) Image histogram and FFT based critical study on noise in fluorescence microscope images. International Conference on Intelligent and Advanced Systems, ICIAS 2016 . http://eprints.utp.edu.my/20176/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
The immune system is a complex network of highly specialized cells (such as lymphocytes) and organs. All of these cells work together to reduce infection (antigens) such as bacteria, virus or tumor cell from the body. Biologic Response Modifiers (BRM) also known as immunotherapy, is a type of treatment which mobilizes and triggers the immune system of the body. This research work provides a description of noise nature of immunofluorescence microscope images. Thus, the study leads to determine the type of noise and choose the filter which best fit the noise presented in fluorescence microscope images. Image histogram and Fast Fourier Transform (FFT) have been applied on blood samples. However, the results show that the Gaussian noise is found in this kind of images. CLAHE filter has been applied to these images. The results obtained from CLAHE demonstrate the ability for this filter to deal with this kind of images. © 2016 IEEE. |
format |
Article |
author |
Mkayes, A.A. Saad, N.M. Faye, I. Walter, N. |
spellingShingle |
Mkayes, A.A. Saad, N.M. Faye, I. Walter, N. Image histogram and FFT based critical study on noise in fluorescence microscope images |
author_facet |
Mkayes, A.A. Saad, N.M. Faye, I. Walter, N. |
author_sort |
Mkayes, A.A. |
title |
Image histogram and FFT based critical study on noise in fluorescence microscope images |
title_short |
Image histogram and FFT based critical study on noise in fluorescence microscope images |
title_full |
Image histogram and FFT based critical study on noise in fluorescence microscope images |
title_fullStr |
Image histogram and FFT based critical study on noise in fluorescence microscope images |
title_full_unstemmed |
Image histogram and FFT based critical study on noise in fluorescence microscope images |
title_sort |
image histogram and fft based critical study on noise in fluorescence microscope images |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012031804&doi=10.1109%2fICIAS.2016.7824039&partnerID=40&md5=3bb91943b41bea4a9523678223eb5581 http://eprints.utp.edu.my/20176/ |
_version_ |
1738656174451982336 |