Image histogram and FFT based critical study on noise in fluorescence microscope images

The immune system is a complex network of highly specialized cells (such as lymphocytes) and organs. All of these cells work together to reduce infection (antigens) such as bacteria, virus or tumor cell from the body. Biologic Response Modifiers (BRM) also known as immunotherapy, is a type of treatm...

Full description

Saved in:
Bibliographic Details
Main Authors: Mkayes, A.A., Saad, N.M., Faye, I., Walter, N.
Format: Article
Published: Institute of Electrical and Electronics Engineers Inc. 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012031804&doi=10.1109%2fICIAS.2016.7824039&partnerID=40&md5=3bb91943b41bea4a9523678223eb5581
http://eprints.utp.edu.my/20176/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
id my.utp.eprints.20176
record_format eprints
spelling my.utp.eprints.201762018-04-22T14:44:33Z Image histogram and FFT based critical study on noise in fluorescence microscope images Mkayes, A.A. Saad, N.M. Faye, I. Walter, N. The immune system is a complex network of highly specialized cells (such as lymphocytes) and organs. All of these cells work together to reduce infection (antigens) such as bacteria, virus or tumor cell from the body. Biologic Response Modifiers (BRM) also known as immunotherapy, is a type of treatment which mobilizes and triggers the immune system of the body. This research work provides a description of noise nature of immunofluorescence microscope images. Thus, the study leads to determine the type of noise and choose the filter which best fit the noise presented in fluorescence microscope images. Image histogram and Fast Fourier Transform (FFT) have been applied on blood samples. However, the results show that the Gaussian noise is found in this kind of images. CLAHE filter has been applied to these images. The results obtained from CLAHE demonstrate the ability for this filter to deal with this kind of images. © 2016 IEEE. Institute of Electrical and Electronics Engineers Inc. 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012031804&doi=10.1109%2fICIAS.2016.7824039&partnerID=40&md5=3bb91943b41bea4a9523678223eb5581 Mkayes, A.A. and Saad, N.M. and Faye, I. and Walter, N. (2017) Image histogram and FFT based critical study on noise in fluorescence microscope images. International Conference on Intelligent and Advanced Systems, ICIAS 2016 . http://eprints.utp.edu.my/20176/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description The immune system is a complex network of highly specialized cells (such as lymphocytes) and organs. All of these cells work together to reduce infection (antigens) such as bacteria, virus or tumor cell from the body. Biologic Response Modifiers (BRM) also known as immunotherapy, is a type of treatment which mobilizes and triggers the immune system of the body. This research work provides a description of noise nature of immunofluorescence microscope images. Thus, the study leads to determine the type of noise and choose the filter which best fit the noise presented in fluorescence microscope images. Image histogram and Fast Fourier Transform (FFT) have been applied on blood samples. However, the results show that the Gaussian noise is found in this kind of images. CLAHE filter has been applied to these images. The results obtained from CLAHE demonstrate the ability for this filter to deal with this kind of images. © 2016 IEEE.
format Article
author Mkayes, A.A.
Saad, N.M.
Faye, I.
Walter, N.
spellingShingle Mkayes, A.A.
Saad, N.M.
Faye, I.
Walter, N.
Image histogram and FFT based critical study on noise in fluorescence microscope images
author_facet Mkayes, A.A.
Saad, N.M.
Faye, I.
Walter, N.
author_sort Mkayes, A.A.
title Image histogram and FFT based critical study on noise in fluorescence microscope images
title_short Image histogram and FFT based critical study on noise in fluorescence microscope images
title_full Image histogram and FFT based critical study on noise in fluorescence microscope images
title_fullStr Image histogram and FFT based critical study on noise in fluorescence microscope images
title_full_unstemmed Image histogram and FFT based critical study on noise in fluorescence microscope images
title_sort image histogram and fft based critical study on noise in fluorescence microscope images
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2017
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85012031804&doi=10.1109%2fICIAS.2016.7824039&partnerID=40&md5=3bb91943b41bea4a9523678223eb5581
http://eprints.utp.edu.my/20176/
_version_ 1738656174451982336